Weifang Sun

Mr. Weifang Sun


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2017 in Materials
Verified
Journal Article
Open access
PDF file
WSWeifang Sun
Weifang Sun
BYBin Yao
Bin Yao
Nianyin ZengNianyin Zeng
Nianyin Zeng
BCBinqiang Chen
Binqiang Chen
YHYuchao He
Yuchao He
WHWangpeng He
Wangpeng He
As a typical example of large and complex mechanical systems, rotating machinery is prone to diversified sorts of mechanical faults. Among these faults, one of the prominent causes of malfunction is generated in gear transmission chains. Although they can be collected via vibration signals, the fault signatures are always submerged in overwhelming interfering contents. Therefore, identifying the critical fault’s characteristic signal is far from an easy task. In order to improve the recognition accuracy of a fault’s characteristic signal, a novel intelligent fault diagnosis method is presented. In this method, a dual-tree complex wavelet transform (DTCWT) is employed to acquire the multiscale signal’s features. In addition, a convolutional neural network (CNN) approach is utilized to automatically recognise a fault feature from the multiscale signal features. The experiment results of the recognition for gear faults show the feasibility and effectiveness of the proposed method, especially in the gear’s weak fault features.

19 May 2020 in IEEE Access
Verified
Journal Article
Open access
ZYZhou Yuqing
Zhou Yuqing
WSWeifang Sun
Weifang Sun
Accurate tool condition monitoring (TCM) is essential for the development of fully automated milling processes. This is typically accomplished using indirect TCM methods that synthesize the information collected from one or more sensors to estimate tool condition based on machine learning approaches. Among the many sensor types available for conducting TCM, motor current sensors offer numerous advantages, in that they are inexpensive, easily installed, and have no effect on the milling process. Accordingly, this study proposes a new TCM method employing a few appropriate current sensor signal features based on the time, frequency, and time–frequency domains of the signals and an advanced monitoring model based on an improved kernel extreme learning machine (KELM). The selected multi-domain features are strongly correlated with tool wear condition and overcome the loss of useful information related to tool condition when employing a single domain. The improved KELM employs a two-layer network structure and an angle kernel function that includes no hyperparameter, which overcome the drawbacks of KELM in terms of the difficulty of learning the features of complex nonlinear data and avoiding the need for preselecting the kernel function and its hyperparameter. The performance of the proposed method is verified by its application to the benchmark NASA milling dataset and separate TCM experiments in comparison with existing TCM methods. The results indicate that the proposed TCM method achieves excellent monitoring performance using only a few key signal features of current sensors.

22 September 2020 in Journal of Intelligent Manufacturing
Verified
Journal Article
Closed access
PDF file
ZYZhou Yuqing
Zhou Yuqing
BSBintao Sun
Bintao Sun
WSWeifang Sun
Weifang Sun
ZLZhi Lei
Zhi Lei

1 December 2020 in Measurement
Verified
Journal Article
Closed access
YZYuqing Zhou
Yuqing Zhou
BSBintao Sun
Bintao Sun
WSWeifang Sun
Weifang Sun

26 September 2019 in IEEE Access
Verified
Journal Article
Open access
BCBinqiang Chen
Binqiang Chen
YLYang Li
Yang Li
XCXincheng Cao
Xincheng Cao
WSWeifang Sun
Weifang Sun
WHWangpeng He
Wangpeng He
The noise cancellation in electrocardiogram (ECG) signal is very influential to distinguish the essential signal features masked by noises. The power line interference (PLI) is the main source of noise in most of bio-electric signals. Digital notch filters can be used to suppress the PLI in ECG signals. However, the problems of transient interferences and the ringing effect occur, especially when the digitization of PLI does not meet the condition of full period sampling. In this paper, to obtain a better cancellation of the PLI, a designing approach, generating adaptive notch filter (ANF) of sharp resolution, is proposed. The proposed method is concise in algorithm and achieves a more comprehensive reduction of the PLI. It only requires on one fast Fourier transform on the input signal. The spectrum correction method, based on the information from the FFT spectrum of the corrupted signal, is utilized to estimate the harmonic parameters of the PLI. The information of a few main lobe spectral bins in the FFT spectrum is merged such that a compensation signal can be synthesized. By subtracting the compensational signal from the original measurement, the PLI within the investigated signal can substantially reduced. A distinguished advantage of the proposed ANF lies in the fact that no parameters are required to be specified, making the algorithm easier to be implemented. The proposed ANF outperforms conventional notch filters because it not only alleviates the undesirable effects but also better preserves the QRS-complex features in the filtered signal.

22 May 2019 in IEEE Access
Verified
Journal Article
Open access
WSWeifang Sun
Weifang Sun
Nianyin ZengNianyin Zeng
Nianyin Zeng
YHYuchao He
Yuchao He
Electrocardiogram (ECG) signal represents the electrical activity of the heart and playing an increasingly important role for practitioners to diagnose heart diseases. Widely available ECG data and machine learning algorithms present an opportunity to improve the accuracy of automated arrhythmia diagnosis. However, a comprehensive evaluation of morphological arrhythmias for ECG analysis across a wide variety of diagnostic classes is still a complex task. This paper presents a generic morphological arrhythmias classification method designed for robust and accurate detection of ECG heartbeat. In this method, the gray-level co-occurrence matrix (GLCM) is employed for features vector description because of its extraordinary statistical feature extraction ability. In addition, the convolutional neural network (CNN) approach is utilized to automatically classification from the generated 3D multi-scale GLCM. Obtained results from the experiments demonstrate that the proposed method in this paper is quite suitable for morphological arrhythmias detection. These findings demonstrate that GLCM description can efficiency extract the shape features vector for a broad range of distinct arrhythmias from lead ECGs with high diagnostic performance. The experimental results of the recognition for morphological arrhythmias show the feasibility and effectiveness of the proposed method and could be used to reduce the rate of misdiagnosed computerized ECG interpretations.