and Daniele Marin

Dr. and Daniele Marin


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Radiology
Verified
Journal Article
Closed access
AMand Daniele Marin
and Daniele Marin
DDDrew Davis
Drew Davis
KCKingshuk Roy Choudhury
Kingshuk Roy Choudhury
BPBhavik Patel
Bhavik Patel
RGRajan T. Gupta
Rajan T. Gupta
RNRendon C. Nelson
Rendon C. Nelson
The authors of this study demonstrate that single-phase contrast-enhanced dual-energy material attenuation analysis significantly improves the specificity for characterization of small (1–4 cm) renal lesions, compared with conventional attenuation measurements (P < .02). PurposeTo determine whether single-phase contrast material–enhanced dual-energy material attenuation analysis improves the characterization of small (1–4 cm) renal lesions compared with conventional attenuation measurements by using histopathologic analysis and follow-up imaging as the clinical reference standards.Materials and MethodsIn this retrospective, HIPAA-compliant, institutional review board–approved study, 136 consecutive patients (95 men and 41 women; mean age, 54 years) with 144 renal lesions (111 benign, 33 malignant) measuring 1–4 cm underwent single-energy unenhanced and contrast-enhanced dual-energy computed tomography (CT) of the abdomen. For each renal lesion, attenuation measurements were obtained; attenuation change of greater than or equal to 15 HU was considered evidence of enhancement. Dual-energy attenuation measurements were also obtained by using iodine-water, water-iodine, calcium-water, and water-calcium material basis pairs. Mean lesion attenuation values and material densitie...

1 June 2016 in American Journal of Roentgenology
Verified
Journal Article
Closed access
AMand Daniele Marin
and Daniele Marin
JRJuan Carlos Ramirez-Giraldo
Juan Carlos Ramirez-Giraldo
SGSonia Gupta
Sonia Gupta
WFWanyi Fu
Wanyi Fu
SSSandra S Stinnett
Sandra S Stinnett
RNRendon C. Nelson
Rendon C. Nelson
OBJECTIVE. The purpose of this study is to investigate whether the reduction in noise using a second-generation monoenergetic algorithm can improve the conspicuity of hypervascular liver tumors on dual-energy CT (DECT) images of the liver. MATERIALS AND METHODS. An anthropomorphic liver phantom in three body sizes and iodine-containing inserts simulating hypervascular lesions was imaged with DECT and single-energy CT at various energy levels (80–140 kV). In addition, a retrospective clinical study was performed in 31 patients with 66 hypervascular liver tumors who underwent DECT during the late hepatic arterial phase. Datasets at energy levels ranging from 40 to 80 keV were reconstructed using first- and second-generation monoenergetic algorithms. Noise, tumor-to-liver contrast-to-noise ratio (CNR), and CNR with a noise constraint (CNRNC) set with a maximum noise increase of 50% were calculated and compared among the different reconstructed datasets. RESULTS. The maximum CNR for the second-generation mono...

3 November 2022 in European Radiology
Verified
Journal Article
Closed access
PDF file
PLPeijie Lyu
Peijie Lyu
NLNana Liu
Nana Liu
BHBrian Harrawood
Brian Harrawood
JSJustin Solomon
Justin Solomon
HWHuixia Wang
Huixia Wang
AMand Daniele Marin
and Daniele Marin

9 February 2023 in European Journal of Radiology
Verified
Journal Article
Closed access
FSFides Regina Schwartz
Fides Regina Schwartz
JAJeffrey Ashton
Jeffrey Ashton
BWBenjamin Wildman-Tobriner
Benjamin Wildman-Tobriner
LMLior Molvin
Lior Molvin
JRJuan Carlos Ramirez-Giraldo
Juan Carlos Ramirez-Giraldo
AMand Daniele Marin
and Daniele Marin

1 September 2018 in American Journal of Roentgenology
Verified
Journal Article
Closed access
BPBhavik N. Patel
Bhavik N. Patel
MRMichael Rosenberg
Michael Rosenberg
FVFederica Vernuccio
Federica Vernuccio
JRJuan Carlos Ramirez-Giraldo
Juan Carlos Ramirez-Giraldo
RNRendon Nelson
Rendon Nelson
AMand Daniele Marin
and Daniele Marin
OBJECTIVE. The objective of this study is to determine whether single-phase contrast-enhanced dual-energy CT (DECT) material attenuation analysis improves the characterization of small (< 2.0 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional single-energy CT evaluation. MATERIALS AND METHODS. This retrospective study involved 55 patients (24 men and 31 women; mean [± SD] age, 63.9 ± 15.3 years) with 77 incidental hypoattenuating hepatic lesions (59 benign and 18 malignant lesions) measuring 0.5–2.0 cm who underwent single-phase contrast-enhanced DECT of the abdomen for pain. For each lesion, attenuation measurements were obtained using blended 120-kVp–equivalent images and contrast map images. DECT material attenuation images were used for iodine quantification. Optimal lesion attenuation and iodine concentration threshold values that best distinguished benign lesions from malignant lesions were generated using smooth bootstrapping. The diagnostic accuracy of the opt...

2 January 2020 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
BPBhavik N. Patel
Bhavik N. Patel
Artem Tarasovic BoltyenkovArtem Tarasovic Boltyenkov
Artem Tarasovic Boltyenkov
MMMaria G. Martinez
Maria G. Martinez
DMDomenico Mastrodicasa
Domenico Mastrodicasa
AMand Daniele Marin
and Daniele Marin
AKAvinash R. Kambadakone
Avinash R. Kambadakone