Introduction: Lateral mass screws (LMS) have been widely used for the posterior fusion of the cervical spine. Even though LMS are safe, the screws are short and postoperative fixation is uncertain. Therefore, we measured and reported a technique using long lateral mass screws (LLMS), a new method of screw insertion, using a Zed spine from LEXI (Tokyo, Japan). Materials and Methods: In this study, we evaluated the outcomes of 35 patients who underwent surgery using LLMS at our hospital from 2019 to 2021. Operative time, blood loss, complications, inserted screw length, screw length based on gender differences, and screw deviation rate were evaluated. The Mann–Whitney U test was used to determine the gender differences in screw length. Screw deviation was evaluated by postoperative CT and a Zed spine to determine the screw insertion angle. Results: The mean operative time was 185 ± 51 min (120–327 min), and the mean blood loss was 236 ± 316 g (10–1720 g). The total number of screws was 183. The screw length was 22.2 (16–28) mm for males and 20.8 (16–28) mm for females, with an average length of 21 ± 2.7 mm. No gender differences were observed in terms of screw length (p > 0.01 NS). The number of deviated screws above G3 was one in the third cervical vertebra, three in the fourth cervical vertebra, one in the fifth cervical vertebra, and one in the sixth cervical vertebra. The number of deviated screws was 6 out of 183, and the deviation rate was 3.2%. Conclusions: In this study, the LLMS deviation rate was 3.2%, and strong fixation was possible without any complications. We measured the screw length and screw deviation rate in cases in which LLMS were actually inserted.
27 March 2025 in Spine Surgery and Related Research
Introduction:This study aimed to compare the biomechanical stress at the proximal junctional aspect between the conventional pedicle screw (PS) fixation (PSF) and the low PS density fixation (LPF) method.Methods:This study involved 10 patients, half of whom have non-osteoporosis and the other half have osteoporosis. We made two types of intact models (one is from the upper thoracic-to-pelvis model, and the other is from the lower thoracic-to-pelvis model). From the intact models, we constructed two kinds of fusion models: (1) PSF and (2) LPF. The LPF method was as follows: The claw hooks (the combination of the down-going transverse process hooks and facet hooks) were set at the upper instrumented vertebra (UIV) and sublaminar wires at the thoracic spine and PSs at the lumbo-pelvis.Results:Upper thoracic to pelvis fixation modelIn non-osteoporosis, no significant difference between the PSF and LPF is found. In osteoporosis, the von Mises stresses of the vertebra body at UIV, UIV + 1, and disc were significantly lower in LPF than in PSF.Lower thoracic-to-pelvis fixation modelIn non-osteoporosis, the average von Mises stress of the vertebral body at UIV + 1 and the maximum stress at UIV were lower in LPF than in PSF; however, no significant difference was found in the others. In osteoporosis, the von Mises stress was significantly lower in LPF than in PSF.Conclusions:The claw hooks stabilized the vertebra body at UIV firmly, and sublaminar wires reduced load translation from the fixed spine.