Edo Abraham

Dr. Edo Abraham

Department of Water management, Delft University of Technology, Delft, Netherlands
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2016 in Water Resources Management
Verified
Journal Article
Open access
PDF file
Manuel HerreraManuel Herrera
Manuel Herrera
Edo AbrahamEdo Abraham
Edo Abraham
ISIvan Stoianov
Ivan Stoianov
Water utilities face a challenge in maintaining a good quality of service under a wide range of operational management and failure conditions. Tools for assessing the resilience of water distribution networks are therefore essential for both operational and maintenance optimization. In this paper, a novel graph-theoretic approach for the assessment of resilience for large scale water distribution networks is presented. This is of great importance for the management of large scale water distribution systems, most models containing up to hundreds of thousands of pipes and nodes. The proposed framework is mainly based on quantifying the redundancy and capacity of all possible routes from demand nodes to their supply sources. This approach works well with large network sizes since it does not rely on precise hydraulic simulations, which require complex calibration processes and computation, while remaining meaningful from a physical and a topological point of view. The proposal is also tailored for the analysis of sectorised networks through a novel multiscale method for analysing connectivity, which is successfully tested in operational utility network models made of more than 100,000 nodes and 110,000 pipes.

24 October 2022 in Nature Energy
Verified
Journal Article
Closed access
PDF file
YMYacob Mulugeta
Yacob Mulugeta
YSYouba Sokona
Youba Sokona
PTPhilipp A. Trotter
Philipp A. Trotter
SFSam Fankhauser
Sam Fankhauser
JOJessica Omukuti
Jessica Omukuti
AYAbdulmutalib Yussuff
Abdulmutalib Yussuff

1 May 2016 in Applied Energy
Verified
Journal Article
Open access
RMRuben Menke
Ruben Menke
Edo AbrahamEdo Abraham
Edo Abraham
PPPanos Parpas
Panos Parpas
ISIvan Stoianov
Ivan Stoianov
Significant changes in the power generation mix are posing new challenges for the balancing systems of the grid. Many of these challenges are in the secondary electricity grid regulation services and could be met through demand response (DR) services. We explore the opportunities for a water distribution system (WDS) to provide balancing services with demand response through pump scheduling and evaluate the associated benefits. Using a benchmark network and demand response mechanisms available in the UK, these benefits are assessed in terms of reduced green house gas (GHG) emissions from the grid due to the displacement of more polluting power sources and additional revenues for water utilities. The optimal pump scheduling problem is formulated as a mixed-integer optimisation problem and solved using a branch and bound algorithm. This new formulation finds the optimal level of power capacity to commit to the provision of demand response for a range of reserve energy provision and frequency response schemes offered in the UK. For the first time we show that DR from WDS can offer financial benefits to WDS operators while providing response energy to the grid with less greenhouse gas emissions than competing reserve energy technologies. Using a Monte Carlo simulation based on data from 2014, we demonstrate that the cost of providing the storage energy is less than the financial compensation available for the equivalent energy supply. The GHG emissions from the demand response provision from a WDS are also shown to be smaller than those of contemporary competing technologies such as open cycle gas turbines. The demand response services considered vary in their response time and duration as well as commitment requirements. The financial viability of a demand response service committed continuously is shown to be strongly dependent on the utilisation of the pumps and the electricity tariffs used by water utilities. Through the analysis of range of water demand scenarios and financial incentives using real market data, we demonstrate how a WDS can participate in a demand response scheme and generate financial gains and environmental benefits

7 December 2015 in Water Resources Research
Verified
Journal Article
Open access
PDF file
RWRobert Wright
Robert Wright
Edo AbrahamEdo Abraham
Edo Abraham
PPPanos Parpas
Panos Parpas
ISIvan Stoianov
Ivan Stoianov
The operation of water distribution networks (WDN) with a dynamic topology is a recently pioneered approach for the advanced management of District Metered Areas (DMAs) that integrates novel developments in hydraulic modeling, monitoring, optimization, and control. A common practice for leakage management is the sectorization of WDNs into small zones, called DMAs, by permanently closing isolation valves. This facilitates water companies to identify bursts and estimate leakage levels by measuring the inlet flow for each DMA. However, by permanently closing valves, a number of problems have been created including reduced resilience to failure and suboptimal pressure management. By introducing a dynamic topology to these zones, these disadvantages can be eliminated while still retaining the DMA structure for leakage monitoring. In this paper, a novel optimization method based on sequential convex programming (SCP) is outlined for the control of a dynamic topology with the objective of reducing average zone pressure (AZP). A key attribute for control optimization is reliable convergence. To achieve this, the SCP method we propose guarantees that each optimization step is strictly feasible, resulting in improved convergence properties. By using a null space algorithm for hydraulic analyses, the computations required are also significantly reduced. The optimized control is actuated on a real WDN operated with a dynamic topology. This unique experimental program incorporates a number of technologies set up with the objective of investigating pioneering developments in WDN management. Preliminary results indicate AZP reductions for a dynamic topology of up to 6.5% over optimally controlled fixed topology DMAs.

1 March 2022 in Journal of Water Resources Planning and Management
Verified
Journal Article
Closed access
PDF file
DSDavid Steffelbauer
David Steffelbauer
JDJochen Deuerlein
Jochen Deuerlein
DGDenis Gilbert
Denis Gilbert
Edo AbrahamEdo Abraham
Edo Abraham
Olivier PillerOlivier Piller
Olivier Piller
Water utilities are challenged to reduce their water losses through detecting, localizing, and repairing leaks as quickly as possible in their aging distribution systems. In this work, we solve this challenging problem by detecting multiple leaks simultaneously in a water distribution network for the Battle of the Leak Detection and Isolation Methods. The performance of leak detection and localization depends on how well the system roughness and demand are calibrated. In addition, existing leaks affect the diagnosis performance unless they are identified and explicitly represented in the model. To circumvent this chicken-and-egg dilemma, we decompose the problem into multiple levels of decision-making (a hierarchical approach) where we iteratively improve the water distribution network model and so are able to solve the multileak diagnosis problem. First, a combination of time series and cluster analysis is used on smart meter data to build patterns for demand models. Second, point and interval estimates of pipe roughnesses are retrieved using least squares to calibrate the hydraulic model, utilizing the demand models from the first step. Finally, the calibrated primal model is transformed into a dual model that intrinsically combines sensor data and network hydraulics. This dual model automatically converts small pressure deviations caused by leaks into sharp and localized signals in the form of virtual leak flows. Analytical derivations of sensitivities with respect to these virtual leak flows are calculated and used to estimate the leakage impulse responses at candidate nodes. Subsequently, we use the dual network to (1) detect the start time of the leaks, and (2) compute the Pearson correlation of pressure residuals, which allows further localization of leaks. This novel dual modeling approach resulted in the highest true-positive rates for leak isolation among all participating teams in the competition.

16 November 2012 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Open access
Edo AbrahamEdo Abraham
Edo Abraham
EKEric C. Kerrigan
Eric C. Kerrigan
This paper investigates optimal active control schemes applied to a point absorber wave energy converter within a receding horizon fashion. A variational formulation of the power maximization problem is adapted to solve the optimal control problem. The optimal control method is shown to be of a bang-bang type for a power takeoff mechanism that incorporates both linear dampers and active control elements. We also consider a direct transcription of the optimal control problem as a general nonlinear program. A variation of the projected gradient optimization scheme is formulated and shown to be feasible and computationally inexpensive compared to a standard NLP solver. Since the system model is bilinear and the cost function is not convex quadratic, the resulting optimization problem is not a quadratic program. Results will be compared with an optimal command latching method to demonstrate the improvement in absorbed power. All time domain simulations are generated under irregular sea conditions.