Daylight usage in buildings improves visual comfort and lowers the final energy demand for artificial lighting. The question that always occurs is how much conservation can be achieved? New or rare materials and constructions have a lack of information about their application. Therefore, the current investigation quantifies the daylight and energy performance of a rare multi-layer textile membrane roof. A translucent, thermal insulation with a glass fibre fleece between the two roof membranes combines daylight usage and heating demand reduction. A sports hall built in 2017 is used as a case study building with 2300 m2 membrane roof surface. The optical properties of the roof construction were measured with a total visual light transmittance τv of 0.72% for a clean surface. A climate-based annual daylight modelling delivers daylight indicators for different construction scenarios. The results show that, in comparison to only one glass façade, the additional translucent and thermally insulated membrane roof construction increases the annual daylight autonomy (DA700) from 0% to 1.5% and the continuous DA700 from 15% to 38%. In the roof-covered areas of the sport field, this results in a 30% reduction of the electricity demand for artificial lighting from 19.7 kWhel/m2/a to 13.8 kWhel/m2/a, when a dimming control is used. The study also found that the influence of the soiling of one layer decreases its light transmittance by a factor 0.81. Two soiled layers lower τv by a factor of 0.66 to 0.47%. This increases the electricity demand for lighting by only 12%. The results should be very valuable as a comparison and benchmark for planners and future buildings of a similar type.
Many installed solar thermally driven cooling systems suffer from high auxiliary electric energy consumption which makes them not more efficient than conventional compression cooling systems. A main reason for this is the use of non-efficient controls with constant set points that do not allow a chiller power modulation at partial-load and therefore lead to unnecessary high power consumption of the parasitics. The aims of this paper are to present a method to control efficiently solar thermally driven chillers, to demonstrate experimentally its applicability and to quantify the benefits. It has been shown that the cooling capacity of a diffusion absorption chiller can be modulated very effectively by adjusting both the temperature and the flow rate of the cooling water. With the developed approach and the use of optimization algorithms, both the temperature and the flow rate can be controlled simultaneously in a way that the cooling load is matched and the electricity consumption is minimized. Depending on the weather and operating conditions, electricity savings between 20% and 60% can be achieved compared to other tested control approaches. The highest savings are obtained when the chiller is operated at partial load. The presented method is not restricted to solar cooling systems and can also be applied to other conventional heating ventilation and air conditioning (HVAC) systems.
Daylight usage in buildings improves visual comfort and lowers the final energy demand for artificial lighting. The question always occurs: how much conservation can you achieve? New upcoming or rare materials and constructions have a lack of information about their application. Therefore, the current work investigates the daylight performance of a multi-layer textile membrane roof with 2 300 m² on top of a sports hall. A translucent, thermal insulation with a glass fibre fleece between the roof membranes combines daylight usage and heating demand reduction. A sports hall with built year 2017 is selected as the case study building. The optical properties of the roof construction are measured. The (visual) light transmittance amounts to 0.72 % with a clean surface. An accordingly parametrized climate-based annual daylight modeling delivers daylight indicators for different construction scenarios. The results show that in comparison to only one glass facade, the additional translucent and thermally insulated membrane construction increases the annual daylight autonomy700/ continuous DA700 from 0/ 15 % to 1.5/ 38 %. In the roof covered areas of the sport field, this results in a reduction from 19.7 to 13.8 kWhel/m²/a electricity for the artificial lighting with dim control (30 % savings). Also, the influence of soiling on the light transmittance was determined with a relevant reduction of one layer about a factor 0.81. The novel results are of great value as a comparison and benchmark for planners and future buildings of similar type.