Christina Huber

Dr. Christina Huber

University Hospital Regensburg, Department of Prosthetic Dentistry
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 December 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
JWJohann Wulff
Johann Wulff
Alois SchmidAlois Schmid
Alois Schmid
CHChristina Huber
Christina Huber
MRMartin Rosentritt
Martin Rosentritt

8 February 2022 in Ceramics
Verified
Journal Article
Open access
PDF file
TSThomas Strasser
Thomas Strasser
Alois SchmidAlois Schmid
Alois Schmid
CHChristina Huber
Christina Huber
MRMartin Rosentritt
Martin Rosentritt
Background: Modern zirconia blanks for the fabrication of dental CAD/CAM restorations provide a layer structure with color and strength transitions. Variation in the yttria content has a particular effect on the characteristics of the materials. The properties of dental restorations may vary depending on the milling position within the blank. Especially for wide-span fixed partial dentures (FPDs), relevant effects on clinical performance might result. This study investigated if the application of high-translucent zirconia and positioning within multilayer zirconia blanks affect the in vitro performance of 4-unit FPDs. Methods: 4-unit FPDs were fabricated from monolayer 3Y-TZP-A, 3Y-TZP, 4Y-TZP, 5Y-TZP, 4Y/5Y-TZP, and different positions within multilayer zirconia blanks (3Y-TZP/5Y-TZP). The FPDs were adhesively luted to resin abutment teeth, divided into groups (n = 8 each): “baseline” (24 h water-storage)/“TCML” (chewing simulation by means of thermalcycling and mechanical loading), and loaded to fracture. The statistics included mean and standard deviation, one-way ANOVA, Bonferroni post hoc test, and Pearson correlation (α = 0.05). Results: The mean fracture force values varied between 803.8 ± 171.7 N (5Y) and 1474.1 ± 193.0 N (3Y) (baseline) and 713.5 ± 190.9 N (5Y) and 1337.4 ± 205.6 N (3Y) (TCML). Significantly different (p = 0.000) results between the groups and individual significant differences (p ≤ 0.039) were found. Conclusions: Positioning within multilayer blanks affected the fracture force only slightly. Multilayer, 3Y-TZP-A, 3Y-TZP, and 4Y-TZP seem appropriate for the clinical application with 4-unit molar FPDs. Application of 5Y-TZP is critical.

1 September 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
CHChristina Huber
Christina Huber
MRMartin Rosentritt
Martin Rosentritt
TSThomas Strasser
Thomas Strasser
MBMichael Behr
Michael Behr