Zoltan Toth

Dr. Zoltan Toth

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
KBKatalin Borbély
Katalin Borbély
MEMiklos Emri
Miklos Emri
IIIstvan Istvan
Istvan Istvan
MTMárton Tóth
Márton Tóth
JSJulia Singer
Julia Singer
IRImre Repa
Imre Repa
The aim of our prospective study was to evaluate the clinical impact of hybrid [18F]-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging ([18F]-FDG PET/MRI) on the decision workflow of epileptic patients with discordant electroclinical and MRI data. A novel mathematical model was introduced for a clinical concordance calculation supporting the classification of our patients by subgroups of clinical decisions. Fifty-nine epileptic patients with discordant clinical and diagnostic results or MRI negativity were included in this study. The diagnostic value of the PET/MRI was compared to other modalities of presurgical evaluation (e.g., electroclinical data, PET, and MRI). The results of the population-level statistical analysis of the introduced data fusion technique and concordance analysis demonstrated that this model could be the basis for the development of a more accurate clinical decision support parameter in the future. Therefore, making the establishment of “invasive” (operable and implantable) and “not eligible for any further invasive procedures” groups could be much more exact. Our results confirmed the relevance of PET/MRI with the diagnostic algorithm of presurgical evaluation. The introduction of a concordance analysis could be of high importance in clinical and surgical decision-making in the management of epileptic patients. Our study corroborated previous findings regarding the advantages of hybrid PET/MRI technology over MRI and electroclinical data.

8 February 2022 in Cancers
Verified
Journal Article
Open access
PDF file
OFOmar Freihat
Omar Freihat
ZTZoltan Toth
Zoltan Toth
TPTamas Pinter
Tamas Pinter
AKAndrás Kedves
András Kedves
DSDavid Sipos
David Sipos
CZCselik Zsolt
Cselik Zsolt
Background: This study aimed to assess the association of 18F-Fluorodeoxyglucose positron-emission-tomography (18F-FDG/PET) and DWI imaging parameters from a primary tumor and their correlations with clinicopathological factors. Methods: We retrospectively analyzed primary tumors in 71 patients with proven HNC. Primary tumor radiological parameters: DWI and FDG, as well as pathological characteristics were analyzed. Spearman correlation coefficient was used to assess the correlation between DWI and FDG parameters, ANOVA or Kruskal–Wallis, independent sample t-test, Mann–Whitney test, and multiple regression were performed on the clinicopathological features that may affect the 18F- FDG and apparent-diffusion coefficient (ADC) of the tumor. Results: No significant correlations were observed between DWI and any of the 18F-FDG parameters (p > 0.05). SUVmax correlated with N-stages (p = 0.023), TLG and MTV correlated with T-stages (p = 0.006 and p = 0.001), and ADC correlated with tumor grades (p = 0.05). SUVmax was able to differentiate between N+ and N− groups (p = 0.004). Conclusions: Our results revealed a non-significant correlation between the FDG-PET and ADC-MR parameters. FDG-PET-based glucose metabolic and DWI-MR-derived cellularity data may represent different biological aspects of HNC.

24 October 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PKPiroska Kallos-Balogh
Piroska Kallos-Balogh
NVNorman Felix Vas
Norman Felix Vas
ZTZoltan Toth
Zoltan Toth
SSSzabolcs Szakall
Szabolcs Szakall
PSPeter Szabo
Peter Szabo
LBLaszlo Balkay
Laszlo Balkay
Previously, we developed an "activity painting" tool for PET image simulation; however, it could simulate heterogeneous patterns only in the air. We aimed to improve this phantom technique to simulate arbitrary lesions in a radioactive background to perform relevant multi-center radiomic analysis. We conducted measurements moving a 22Na point source in a 20-liter background volume filled with 5 kBq/mL activity with an adequately controlled robotic system to prevent the surge of the water. Three different lesion patterns were "activity-painted" in five PET/CT cameras, resulting in 8 different reconstructions. We calculated 46 radiomic indeces (RI) for each lesion and imaging setting, applying absolute and relative discretization. Reproducibility and reliability were determined by the inter-setting coefficient of variation (CV) and the intraclass correlation coefficient (ICC). Hypothesis tests were used to compare RI between lesions. By simulating precisely the same lesions, we confirmed that the reconstructed voxel size and the spatial resolution of different PET cameras were critical for higher order RI. Considering conventional RIs, the SUVpeak and SUVmean proved the most reliable (CV<10%). CVs above 25% are more common for higher order RIs, but we also found that low CVs do not necessarily imply robust parameters but often rather insensitive RIs. Based on the hypothesis test, most RIs could clearly distinguish between the various lesions using absolute resampling. ICC analysis also revealed that most RIs were more reproducible with absolute discretization. The activity painting method in a real radioactive environment proved suitable for precisely detecting the radiomic differences derived from the different camera settings and texture characteristics. We also found that inter-setting CV is not an appropriate metric for analyzing RI parameters’ reliability and robustness. Although multicentric cohorts are increasingly common in radiomics analysis, realistic texture phantoms can provide indispensable information on the sensitivity of an RI and how an individual RI parameter measures the texture.

1 September 2009 in Donald School Journal of Ultrasound in Obstetrics and Gynecology
Verified
Journal Article
Open access
ZTZoltan Toth
Zoltan Toth
JAJános Aranyosi
János Aranyosi
TDTamás Deli
Tamás Deli
PBPéter Bettembuk
Péter Bettembuk
BKBence Kozma
Bence Kozma
OTOlga Török
Olga Török
Identical hemodynamic impedance and constant ratio of the fetal descending aorta and middle cerebral artery of uncomplicated pregnancies at term. Fetal aortic-cerebral Doppler resistance index ratio: An indicator of physiologic blood flow distribution. Objective: To interpret the physiologic fetal arterial blood flow distribution by relating the vascular impedance of the fetal descending aorta (DA) and middle cerebral artery (MCA) and to establish the reference ranges for the aortic-cerebral Doppler resistance index ratio (ACRI). Study design: Ninety-six patients with uncomplicated pregnancies were recruited for the cross-sectional assessment of the Doppler resistance index (RI) in the fetal DA and MCA between the 38rd and 40th weeks of gestation. The normal ranges of the ACRI were calculated. A cut-off value was designed to facilitate the clinical application of the ACRI. Results: Between the 38th and 40th weeks of gestation in normal pregnancies the ACRI of healthy fetuses is constant, the overall mean is: 1.062 (+/– 0.087). A single cut-off value of 1.2 is recommended to assist separating normal and pathologic arterial blood flow patterns. Conclusion: The normal ACRI reflects the identical vascular resistance of the descending aorta and the cerebral vessels, which maintains the physiologic fetal central arterial blood flow. Additional clinical studies are necessary to assess the diagnostic efficacy of the abnormal ACRI (>1.2) as a potentially useful marker of the centralized arterial circulation indicating the early stage of fetal hypoxemic jeopardy.

1 August 2007 in Blood Reviews
Verified
Journal Article
Closed access
Gabor MikalaGabor Mikala
Gabor Mikala
ABA. Batai
A. Batai
Imre BodóImre Bodó
Imre Bodó
ZCZ. Csukly
Z. Csukly
JDJ. Dolgos
J. Dolgos
TMTamás Masszi
Tamás Masszi