Percutaneous vertebroplasty procedure is of major importance, given the significantly increasing aging population and the higher number of orthopedic procedures related to vertebral compression fractures. Vertebroplasty is a complex technique involving the injection of polymethylmethacrylate (PMMA) into the compressed vertebral body for mechanical stabilization of the fracture. Our understanding and ability to modify these mechanisms through alterations in cement material is rapidly evolving. However, the rate of cardiac complications secondary to PMMA injection and subsequent cement leakage has increased with time. The following review considers the main effects of PMMA bone cement on the heart, and the extent of influence of the materials on cardiac embolism. Clinically, cement leakage results in life‐threatening cardiac injury. The convolution of this outcome through an appropriate balance of complex material properties is highlighted via clinical case reports.
The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes. Examples include miniaturized sensors for monitoring intraocular pressure and blood pressure, which are designed in an ultra-thin diaphragm to react with the applied pressure. These sensors are integrated into rigid circuits and multiple modules; this brings challenges regarding the fundamental material’s property mismatch with the targeted human tissues, which are intrinsically soft. Therefore, many polymeric materials have been investigated for hybrid integration with well-characterized functional materials such as silicon membranes and metal interconnects, which enable soft implantable bioelectronics. The most recent trend in implantable systems uses transient materials that naturally dissolve in body fluid after a programmed lifetime. Such biodegradable metallic materials are advantageous in the design of electronics due to their proven electrical properties. Collectively, this review delivers the development history of materials in implantable devices, while introducing new bioelectronics based on bioresorbable materials with multiple functionalities.
3 September 2018 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Percutaneous vertebroplasty procedure is of major importance, given the significant increasing aging population and higher number of orthopedic procedures related to vertebral compression fractures. Vertebroplasty is a complex technique involving injection of polymethylmethacrylate (PMMA) into the compressed vertebral body for mechanical stabilization of the fracture. Our understanding and ability to modify these mechanisms through alterations in cement material is rapidly evolving. However, the rate of cardiac complications secondary to PMMA injection and subsequent cement leakage has increased with time. The following review considers the main features of PMMA bone cement on the heart, and the extent of influence of materials on cardiac embolism. Clinically, cement leakage results in life-threatening cardiac injury. The convolution of this outcome through an appropriate balance of complex material properties is highlighted via clinical case report.
Smart nitinol guidewires have been proposed to improve trackability, facilitating the advancement of catheters through complex vascular anatomies during neurovascular interventions. A smart 0.015 in. diameter nitinol guidewire was actualized through Joule heating of one-way and two-way shape memory alloys (SMA). The device functionalities in terms of bending performance were analyzed: (1) trackability of a 4 Fr catheter as determined in an anatomically correct in vitro environment; (2) time and spatial response of the smart guidewire as a function of material temperature and applied current; and (3) thrombogenic effects as a function of temperature and applied voltage. The results suggest that smart guidewires have substantially improved trackability (i.e., deflection of 15 deg) to overcome the “ledge effect” with the absence of thrombogenicity via a smart guidewire–catheter combined transcatheter based procedure which keeps the catheter surface temperature at 30–33 °C.