Johanne Heitmann Solheim

Ms. Johanne Heitmann Solheim


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2019 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
JSJohanne Heitmann Solheim
Johanne Heitmann Solheim
EGEvgeniy Gunko
Evgeniy Gunko
DPDennis Petersen
Dennis Petersen
FGFrederik Großerüschkamp
Frederik Großerüschkamp
KGKlaus Gerwert
Klaus Gerwert
AKAchim Kohler
Achim Kohler

15 March 2022 in Molecules
Verified
Journal Article
Open access
PDF file
JSJohanne Heitmann Solheim
Johanne Heitmann Solheim
BZBoris Zimmermann
Boris Zimmermann
VTValeria Tafintseva
Valeria Tafintseva
SDSimona Dzurendova
Simona Dzurendova
VSVolha Shapaval
Volha Shapaval
AKAchim Kohler
Achim Kohler
Extended multiplicative signal correction (EMSC) is a widely used preprocessing technique in infrared spectroscopy. EMSC is a model-based method favored for its flexibility and versatility. The model can be extended by adding constituent spectra to explicitly model-known analytes or interferents. This paper addresses the use of constituent spectra and demonstrates common pitfalls. It clarifies the difference between analyte and interferent spectra, and the importance of orthogonality between model spectra. Different normalization approaches are discussed, and the importance of weighting in the EMSC is demonstrated. The paper illustrates how constituent analyte spectra can be estimated, and how they can be used to extract additional information from spectral features. It is shown that the EMSC parameters can be used in both regression tasks and segmentation tasks.

15 April 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
SSSlobodan Sirovica
Slobodan Sirovica
JSJohanne Heitmann Solheim
Johanne Heitmann Solheim
MSMaximilian W. A. Skoda
Maximilian W. A. Skoda
CHCarol J. Hirschmugl
Carol J. Hirschmugl
EMEric C. Mattson
Eric C. Mattson
OAOwen Addison
Owen Addison
Photo-activated resin composites are widely used in industry and medicine. Despite extensive chemical characterisation, the micro-scale pattern of resin matrix reactive group conversion between filler particles is not fully understood. Using an advanced synchrotron-based wide-field IR imaging system and state-of-the-art Mie scattering corrections, we observe how the presence of monodispersed silica filler particles in a methacrylate based resin reduces local conversion and chemical bond strain in the polymer phase. Here we show that heterogeneity originates from a lower converted and reduced bond strain boundary layer encapsulating each particle, whilst at larger inter-particulate distances light attenuation and monomer mobility predominantly influence conversion. Increased conversion corresponds to greater bond strain, however, strain generation appears sensitive to differences in conversion rate and implies subtle distinctions in the final polymer structure. We expect these findings to inform current predictive models of mechanical behaviour in polymer-composite materials, particularly at the resin-filler interface.

27 January 2022 in Molecules
Verified
Journal Article
Open access
PDF file
VTValeria Tafintseva
Valeria Tafintseva
TLTiril Aurora Lintvedt
Tiril Aurora Lintvedt
JSJohanne Heitmann Solheim
Johanne Heitmann Solheim
BZBoris Zimmermann
Boris Zimmermann
HRHafeez Ur Rehman
Hafeez Ur Rehman
AKAchim Kohler
Achim Kohler
The aim of the study was to optimize preprocessing of sparse infrared spectral data. The sparse data were obtained by reducing broadband Fourier transform infrared attenuated total reflectance spectra of bovine and human cartilage, as well as of simulated spectral data, comprising several thousand spectral variables into datasets comprising only seven spectral variables. Different preprocessing approaches were compared, including simple baseline correction and normalization procedures, and model-based preprocessing, such as multiplicative signal correction (MSC). The optimal preprocessing was selected based on the quality of classification models established by partial least squares discriminant analysis for discriminating healthy and damaged cartilage samples. The best results for the sparse data were obtained by preprocessing using a baseline offset correction at 1800 cm−1, followed by peak normalization at 850 cm−1 and preprocessing by MSC.

20 February 2021 in CARTILAGE
Verified
Journal Article
Closed access
PDF file
VVVesa Virtanen
Vesa Virtanen
ENErvin Nippolainen
Ervin Nippolainen
RSRubina Shaikh
Rubina Shaikh
IAIsaac O. Afara
Isaac O. Afara
JTJuha Töyräs
Juha Töyräs
LRLassi Rieppo
Lassi Rieppo
Objective: Joint injuries may lead to degeneration of cartilage tissue and initiate development of posttraumatic osteoarthritis. Arthroscopic surgeries can be used to treat joint injuries, but arthroscopic evaluation of articular cartilage quality is subjective. Fourier transform infrared spectroscopy combined with fiber optics and attenuated total reflectance crystal could be used for the assessment of tissue quality during arthroscopy. We hypothesize that fiber-optic mid-infrared spectroscopy can detect enzymatically and mechanically induced damage similar to changes occurring during progression of osteoarthritis. Design: Bovine patellar cartilage plugs were extracted and degraded enzymatically and mechanically. Adjacent untreated samples were utilized as controls. Enzymatic degradation was done using collagenase and trypsin enzymes. Mechanical damage was induced by (1) dropping a weight impactor on the cartilage plugs and (2) abrading the cartilage surface with a rotating sandpaper. Fiber-optic mid-infrared spectroscopic measurements were conducted before and after treatments, and spectral changes were assessed with random forest, partial least squares discriminant analysis, and support vector machine classifiers. Results: All models had excellent classification performance for detecting the different enzymatic and mechanical damage on cartilage matrix. Random forest models achieved accuracies between 90.3% and 77.8%, while partial least squares model accuracies ranged from 95.8% to 84.7%, and support vector machine accuracies from 91.7% to 80.6%. Conclusions: The results suggest that fiber-optic Fourier transform infrared spectroscopy attenuated total reflectance spectroscopy is a viable way to detect minor and major degeneration of articular cartilage. Objective measures provided by fiber-optic spectroscopic methods could improve arthroscopic evaluation of cartilage damage.

1 September 2021 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
JSJohanne Heitmann Solheim
Johanne Heitmann Solheim
Ferenc BorondicsFerenc Borondics
Ferenc Borondics
BZBoris Zimmermann
Boris Zimmermann
CSChristophe Sandt
Christophe Sandt
FMFlorian Muthreich
Florian Muthreich
AKAchim Kohler
Achim Kohler
In infrared spectroscopy of thin film samples, interference introduces distortions in spectra, commonly referred to as fringes. Fringes may alter absorbance peak ratios, which hampers the spectral analysis. We have previously introduced extended multiplicative signal correction (EMSC) for fringes correction. In the current article, we provide a robust open‐source algorithm for fringe correction in infrared spectroscopy and propose several improvements to the Fringe EMSC model. The suggested algorithm achieves a more precise fringe frequency estimation by mean centering of the measured spectrum and applying a window function prior to the Fourier transform. It selects two frequencies from a user defined number of maxima in the Fourier domain. The improved Fringe EMSC algorithm is validated on two experimental datasets, one of them being a hyperspectral image. Techniques for separating sample spectra from background spectra in hyperspectral images, and techniques to identify spectra affected by fringes are also provided.