Nicolas J. Pejovic

Dr. Nicolas J. Pejovic

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2013 in Acta Paediatrica
Verified
Journal Article
Open access
PDF file
NPNicolas J. Pejovic
Nicolas J. Pejovic
Eric HerleniusEric Herlenius
Eric Herlenius
Aim: To determine the occurrence and risk factors of sudden unexpected postnatal collapse (SUPC) in presumably healthy newborn infants.Methods: All live‐born infants during a 30‐month period, in five major delivery wards in Stockholm, were screened, and possible cases of SUPC thoroughly investigated. Infants were ≥35 weeks of gestation, had an Apgar score >8 at 10 min and collapsed within 24 h after birth. Maternal, infant, event characteristics and outcome data were collected.Results: Twenty‐six cases of SUPC were found among 68 364 live‐born infants, an incidence of 38/100 000 live births. Sixteen of these cases of SUPC required resuscitation with ventilation >1 min, and 14 of these remained unexplained (21/100 000). Fifteen of the 26 children were found in a prone position, during skin‐to‐skin contact, 18 were primipara, and 13 occurred during unsupervised breastfeeding at <2 h of age. Three cases occurred during smart cellular phone use by the mother. Five developed hypoxic–ischaemic encephalopathy (HIE) grade 2, and 4 underwent hypothermia treatment. Twenty‐five infants had a favourable neurological outcome.Conclusion: SUPC in apparent healthy babies is associated with initial, unsupervised breastfeeding, prone position, primiparity and distractions. Guidelines outlining the appropriate monitoring of newborns and safe early skin‐to‐skin contact should be implemented.

14 September 2017 in Archives of Disease in Childhood
Verified
Journal Article
Open access
PDF file
NPNicolas J. Pejovic
Nicolas J. Pejovic
DTDaniele Trevisanuto
Daniele Trevisanuto
CLClare Lubulwa
Clare Lubulwa
SHSusanna Myrnerts Höök
Susanna Myrnerts Höök
FCFrancesco Cavallin
Francesco Cavallin
TTThorkild Tylleskär
Thorkild Tylleskär
Objective Mortality rates from birth asphyxia in low-income countries remain high. Face mask ventilation (FMV) performed by midwives is the usual method of resuscitating neonates in such settings but may not always be effective. The i-gel is a cuffless laryngeal mask airway (LMA) that could enhance neonatal resuscitation performance. We aimed to compare LMA and face mask (FM) during neonatal resuscitation in a low-resource setting. Setting Mulago National Referral Hospital, Kampala, Uganda. Design This prospective randomised clinical trial was conducted at the labour ward operating theatre. After a brief training on LMA and FM use, infants with a birth weight >2000 g and requiring positive pressure ventilation at birth were randomised to resuscitation by LMA or FM. Resuscitations were video recorded. Main outcome measures Time to spontaneous breathing. Results Forty-nine (24 in the LMA and 25 in the FM arm) out of 50 enrolled patients were analysed. Baseline characteristics were comparable between the two arms. Time to spontaneous breathing was shorter in LMA arm than in FM arm (mean 153 s (SD±59) vs 216 s (SD±92)). All resuscitations were effective in LMA arm, whereas 11 patients receiving FM were converted to LMA because response to FMV was unsatisfactory. There were no adverse effects. Conclusion A cuffless LMA was more effective than FM in reducing time to spontaneous breathing. LMA seems to be safe and effective in clinical practice after a short training programme. Its potential benefits on long-term outcomes need to be assessed in a larger trial. Clinical trial registry This trial was registered in https://clinicaltrials.gov, with registration number NCT02042118.

11 June 2020 in Global Health Action
Verified
Journal Article
Open access
BOBeatrice Odongkara
Beatrice Odongkara
Thorkild TylleskärThorkild Tylleskär
Thorkild Tylleskär
NPNicolas J. Pejovic
Nicolas J. Pejovic
VAVincentina Achora
Vincentina Achora
DMDavid Mukunya
David Mukunya
VNVictoria Nankabirwa
Victoria Nankabirwa
Skilled birth attendants must be competent to provide prompt resuscitation to save newborn lives at birth. Both knowledge and skills (competence) decline with time after training but the optimal du...

1 February 2022 in Resuscitation
Verified
Journal Article
Closed access
NPNicolas J. Pejovic
Nicolas J. Pejovic
FCFrancesco Cavallin
Francesco Cavallin
AMAllan Mpamize
Allan Mpamize
CLClare Lubulwa
Clare Lubulwa
SHSusanna Myrnerts Höök
Susanna Myrnerts Höök
DTDaniele Trevisanuto
Daniele Trevisanuto

10 November 2016 in Acta Paediatrica
Verified
Journal Article
Open access
PDF file
NPNicolas J. Pejovic
Nicolas J. Pejovic
DTDaniele Trevisanuto
Daniele Trevisanuto
JNJolly Nankunda
Jolly Nankunda
TTThorkild Tylleskär
Thorkild Tylleskär
Aim: We compared the performance of personnel in a low‐resource setting when they used the I‐gel cuffless neonatal laryngeal mask or a face mask on a neonatal airway management manikin.Methods: At Mulago Hospital, Uganda, 25 doctors, nurses and midwives involved in neonatal resuscitation were given brief training with the I‐gel and face mask. Then, every participant was observed positioning both devices on three consecutive occasions. The success rate and insertion times leading to effective positive pressure ventilation (PPV) were recorded. Participants rated the perceived efficiency of the devices using a five‐point Likert scale.Results: The I‐gel achieved a 100% success rate on all three occasions, but the face mask was significantly less effective in achieving effective PPV and the failure rates at the first, second and third attempts were 28%, 8% and 20%, respectively. The perceived efficiency of the devices was significantly superior for the I‐gel (4.7 ± 0.4) than the face mask (3.3 ± 0.8).Conclusion: The I‐gel was more effective than the face mask in establishing PPV in the manikin, and user satisfaction was higher. These encouraging manikin data could be a stepping stone for clinical research on the use of the I‐gel for neonatal resuscitation in low‐resource settings.

31 March 2018 in Acta Paediatrica
Verified
Journal Article
Open access
PDF file
SHSusanna Myrnerts Höök
Susanna Myrnerts Höök
NPNicolas J. Pejovic
Nicolas J. Pejovic
GMGaetano Marrone
Gaetano Marrone
TTThorkild Tylleskär
Thorkild Tylleskär
TATobias Alfvén
Tobias Alfvén
Aim: This study determined the accuracy and speed of the NeoTapLifeSupport (NeoTapLS), a free smartphone application that aims to assess a neonate's heart rate.Methods: We asked 30 participants with a variety of backgrounds to test the NeoTapLS, which was developed by our own nonprofit organisation Tap4Life, to determine a randomly selected heart rate by auscultation or palpation. The study was carried out in 2014 at Sachs’ Children and Youth Hospital, Sweden, using a Laerdal SimNewB manikin that simulates true values. The NeoTapLS calculates the heart rate based on the user's last three taps on the smartphone screen.Results: A total of 1200 measurements were carried out. A high correlation was found between measured and true values by auscultation (correlation coefficient 0.993) as well as by palpation (correlation coefficient 0.986) with 93.5% of the auscultations and 86.3% of the palpations differing from the true value by five beats or fewer. The mean time to the first estimated heart rate was 14.9 seconds for auscultation and 16.3 seconds for palpation.Conclusion: Heart rates could be accurately and rapidly assessed using the NeoTapLS on a manikin. A globally accessible mobile health system could offer a low‐cost alternative to expensive medical equipment.