Release of deuterium from falling droplets of Pb-17Li in vacuum is experimentally studied. By comparing different diameter nozzle data each other, the effect of ambiguous solution is eliminated, and reliable result is attained. The amount of deuterium that is dissolved into Pb-17Li, followed by the release from the liquid droplets in vacuum, is measured with four different diameter nozzles ranging from 0.4 mm-1.0 mm under an initial velocity of 3.0 m/s and four temperatures between 375 °C and 450 °C. The resultant mass transport, represented by quasi-dispersion-coefficient is 3.4 × 10-7 [m2/s], which is approximately two orders of magnitude faster than previous studies under static condition. It also revealed different temperature dependency. Cyclic deformation of the sphere shape is observed with a high speed movie camera. These results show the falling droplets of liquid Pb-17Li in vacuum follow the mass transfer mechanism under convection prior domain by self-excited oscillation. This result suggests that the tritium recovery method from a breeding liquid Pb-17Li blanket is viable when using multiple nozzles in vacuum for the extraction.
Quantitative feasibility analysis of the tritium recovery efficiency from multiple columns of liquid PbLi droplets was conducted.Then a case study based on the HCLL specification was performed. Main concern was whether the experimentally obtained recovery efficiency from a column of droplets is applicable for the efficiency estimation from the multiple columns of droplets without any mutual degrading effects. To maintaining a safe side assumption, the tritium once released and reabsorbed on another droplet was considered to be not re-emitted while falling. By the analogy with the thermal radiation theory, the view factor which expresses the intersection ratio of radiation on another surface was applied for the estimation.The dependences on nozzle design parameters, such as nozzle pitch, number of nozzles, chamber wall clearance, and exhaust port design, were investigated. Case study results suggest that, by choosing well-suited parameters approximately 40% to 60% of the single column recovery efficiency was secured for multiple columns even on the conservative condition. The release chamber exhaust port design had a major influence. Nozzle pitch and array design have less influences, but are not negligible. However, it has to be experimentally verified to the scale-size effects and experimental programs are currently underway.