David Alejandro Guizado Vidal

Dr. David Alejandro Guizado Vidal

Universidade Federal de Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JPJairo Michael Valdivia Prado
Jairo Michael Valdivia Prado
David Alejandro Guizado VidalDavid Alejandro Guizado Vidal
David Alejandro Guizado Vidal
jose floresjose flores
jose flores
DGDelia Gamarra
Delia Gamarra
YSYamina Silva
Yamina Silva
EGEdith Rosana Huaman Guadalupe
Edith Rosana Huaman Guadalupe
The research presents the inter-comparison of atmospheric variables measured by 9 automatic weather stations. This set of data was compared with the measurements of other weather stations in order to standardize the values that must be adjusted when taken to different areas. The data of a set of a total of 9 GMX500, which measures conventional meteorological variables, and 10 WS100 sensors, which measures precipitation parameters. The automatic stations were set up at the Huancayo Observatory (Geophysical Institute of Peru) for a period of 5 months. The data set of GMX500 were evaluated comparing with the average of the 9 sensors and the WS100 was compared with an optical disdrometer Parsivel2. The temperature, pressure, relative humidity, wind speed, rainfall rate, and drop size distribution were evaluated. A pair of GMX500 sensors presented high data dispersion; it was found found that the errors came from a bad configuration; once this problem was solved, good agreement was archived, with low RMSE and high correlation. It was found that the WS100 sensors overestimate the precipitation with a percentage bias close to 100% and the differences increase with the greater intensity of rain. The drop size distribution retrieved by WS100 have unrealistic behavior with higher concentrations in diameters of 1 mm and 5 mm, in addition to a flattened curve.

7 February 2022 in Preprints.org
Verified
Preprint
Open access
JVJairo M. Valdivia
Jairo M. Valdivia
David Alejandro Guizado VidalDavid Alejandro Guizado Vidal
David Alejandro Guizado Vidal
jose floresjose flores
jose flores
DGDelia P. Gamarra
Delia P. Gamarra
YSYamina F. Silva
Yamina F. Silva
LSLuis Suarez-Salas
Luis Suarez-Salas
The research presents the inter-comparison of atmospheric variables measured by 9 automatic meteorological stations. This set of data was compared with the measurements of other meteorological stations in order to standardize the values that must be adjusted when taken to different areas. The data of a set of a total of 9 GMX500, which measures conventional meteorological variables, and 10 WS100 sensors, which measures precipitation parameters. The automatic stations were set up at the Huancayo Observatory (Geophysical Institute of Peru) for a period of 5 months. The data set of GMX500 were evaluated comparing with the average of the 9 sensors and the WS100 was compared with a optical disdrometer Parsivel2. The temperature, pressure, relative humidity, wind speed, rainfall rate, and drop size distribution was evaluated. A pair of GMX500 sensors presented high data dispersion, it was found found that the errors came from a bad configuration; once this problem was solved, good agreement was archived, with low RMSE and high correlation. I was found that the WS100 sensors overestimate the precipitation with a percent bias close to 100% and the differences increase with the greater intensity of rain. The DSD retrieved by WS100 have unrealistic behavior with higher concentrations in diameters of 1 mm and 5 mm, in addition to a flattened curve.