Laura Ferrer

Dr. Laura Ferrer

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2005 in Journal of Coastal Research
Verified
Journal Article
Closed access
JMJorge Marcovecchio
Jorge Marcovecchio
Laura FerrerLaura Ferrer
Laura Ferrer

5 January 2012 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
JAJessica Avivar
Jessica Avivar
Laura FerrerLaura Ferrer
Laura Ferrer
MCMontserrat Casas
Montserrat Casas
VMVICTOR CERDA MARTIN
VICTOR CERDA MARTIN
An on-line solid-phase extraction method linked to inductively coupled mass spectrometry (ICP-MS) has been developed for the determination of low levels of uranium and thorium in environmental samples. The hyphenation of lab-on-valve (LOV) and multisyringe flow injection analysis (MSFIA), coupled to an ICP-MS, allows the simultaneous determination of thorium and uranium in different types of environmental sample matrices achieving high selectivity and sensitivity levels. On-line separation and preconcentration of thorium and uranium are carried out by means of UTEVA resin. The potential of the LOV-MSFIA makes possible the full automation of the system by the on-line regeneration of the column. The limits of detection reached are 0.4 ng L−1 of uranium and 2.8 ng L−1 of thorium. The reproducibility of the LOV-MSFIA-ICP-MS is 1.7% of RSD. Moreover, a high sensitivity, a wide working range (0–200 μg L−1 for uranium and thorium) and an injection frequency up to 9 h−1 (depending on the sample volume) should be highlighted. Different water sample matrices (seawater, well water, freshwater, tap water and mineral water), a phosphogypsum sample with natural uranium and thorium content and a channel sediment reference material were satisfactorily analyzed with the proposed method.

1 August 2016 in Talanta
Verified
Journal Article
Closed access
FSFernanda A. de Santana
Fernanda A. de Santana
LPLindomar A. Portugal
Lindomar A. Portugal
ASAntonio M. Serra
Antonio M. Serra
Laura FerrerLaura Ferrer
Laura Ferrer
VCVíctor Cerdà
Víctor Cerdà
SFSergio Luis Costa Ferreira
Sergio Luis Costa Ferreira

16 January 2015 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
BBB. Beltrán
B. Beltrán
LLLuz O. Leal
Luz O. Leal
Laura FerrerLaura Ferrer
Laura Ferrer
VMVICTOR CERDA MARTIN
VICTOR CERDA MARTIN
A multicommuted system has been developed for lead (Pb) isolation, pre-concentration and determination using an atomic fluorescence spectrometer as the detector. The lab-on-valve (LOV) technique allows automatic separation and pre-concentration of lead by means of solid phase extraction. The Pb resin was conditioned with nitric acid (1 mol L−1) and the analyte was eluted with 1.3 mol L−1 glycine solution. Chemical and flow variables affecting the extraction/pre-concentration of Pb2+ were investigated by a multivariate approach. First, screening of the independent variables and their interactions was carried out by a two level full factorial design (2k). Then, a face centered central composite design was performed in order to find the optimal values of the significant variables. Because a wide range of sample volumes can be loaded on the microcolumn (1–100 mL), a mass calibration curve was obtained in order to quantify Pb in sample batches with a wide variability in lead concentration. Under optimal conditions, the limit of detection and the quantification limit were 0.004 and 0.014 ng of Pb2+, respectively. The linear response range was 0.014–20 ng of Pb2+. The repeatability, expressed as relative standard deviation (RSD), is 2.4% for 4 μg L−1 Pb2+ (n = 10). A small amount (0.6 g) of Pb resin is enough to fill the microcolumn of the LOV device. The durability of the resin reached 154 injections. The injection frequency permitted between a sample frequency of 1–10 h−1 depending on the sample pre-concentration volume. This method was validated using certified reference materials such as SRM-1400 (bone ash), SRM-2976 (mussel tissue) and BCR-610 (groundwater), and the results obtained showed good agreement with the certified values. The proposed LOV system was successfully applied to different samples of environmental and biological interest (water, fish and human teeth) with satisfactory recoveries, between 90–110%. The proposed system has some advantages such as minimization of sample handling, sensitivity, good precision, reduction of reagent volumes, high durability of the column and the versatility achieved by a variety of managed sample volumes.

1 February 2016 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
Rogelio Rodríguez-MaeseRogelio Rodríguez-Maese
Rogelio Rodríguez-Maese
JAJessica Avivar
Jessica Avivar
LLLuz O. Leal
Luz O. Leal
VMVICTOR CERDA MARTIN
VICTOR CERDA MARTIN
Laura FerrerLaura Ferrer
Laura Ferrer

1 December 2004 in Talanta
Verified
Journal Article
Closed access
Laura FerrerLaura Ferrer
Laura Ferrer
GAGraciela De Armas
Graciela De Armas
MMManuel Miró
Manuel Miró
JEJosé Manuel Estela
José Manuel Estela
VMVICTOR CERDA MARTIN
VICTOR CERDA MARTIN