Júlia Mestres

Ms. Júlia Mestres

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
JMJúlia Mestres
Júlia Mestres
Francesca LeonardiFrancesca Leonardi
Francesca Leonardi
KMKlaus Mathwig
Klaus Mathwig
Electrochemical sensors are powerful tools for the detection and real-time monitoring of a wide variety of analytes. However, the long-term operation of Faradaic sensors in complex media is challenging due to fouling. The protection of the electrode surface during in vivo operation is a key element for improving the monitoring of analytes. Here, we study different EUDRAGIT® controlled release acrylate copolymers for protecting electrode surfaces. The dissolution of these polymers—namely EUDRAGIT® L 30 D-55 and EUDRAGIT® FS 30 D—is triggered by a change in pH of the environment, and it is electrochemically monitored by detecting electrode access by means of a redox probe. The full dissolution of the polymer is achieved within 30 min and the electrode response indicates a complete recovery of the original electrochemical performance. We demonstrate that amperometric sensing is a practical and straightforward technique for real-time and in situ sensing of EUDRAGIT® dissolution profiles. It will find future applications in determining the protection of polymer electrode coating in real matrices and in vivo applications.

25 August 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JMJúlia Mestres
Júlia Mestres
Francesca LeonardiFrancesca Leonardi
Francesca Leonardi
EKEsther Kho
Esther Kho
VDVan Anh Dam
Van Anh Dam
SMStijn Mom
Stijn Mom
AAAnita Ahmadi
Anita Ahmadi
Miniaturization of solid-contact ion-selective electrodes (SC-ISEs) have emerged as a promising alternative in various applications, including clinical diagnostics, environmental monitoring, and industrial processes. Here, we describe the fabrication of a miniaturized SC-ISE featuring a carbon ink-modified electric contact prepared via a straightforward drop-casting method. This approach enables a simple and scalable manufacturing process for SC-ISEs. The morphology and the electrochemical properties of this carbon-coated electrode have been investigated prior to the deposition of a Na+ ion-selective membrane. The developed Na+–ISEs show linear sensitivity in the range of 10-3 to 1 M (54 ± 2 mV/decade) and a selectivity coefficient of –4.3, –3.9, –5.2, –4.3 in the presence of K+, NH4 +, Ca2+, and Mg2+, respectively, according to the fixed interference method. This study integrates an easy drop-casting technique with a multi-electrode, chip-based platform. The findings of this study contribute to the growing body of knowledge of ISEs and offer valuable insights for the further advancement of electrochemical sensing technologies.


16 September 2025 in Electroanalysis
Verified
Journal Article
Open access
JMJúlia Mestres
Júlia Mestres
JGJayaruwan G. Gamaethiralalage
Jayaruwan G. Gamaethiralalage
LSLouis De Smet
Louis De Smet
Francesca LeonardiFrancesca Leonardi
Francesca Leonardi
Polyanions have been introduced as replacements for poly(vinyl chloride) (PVC) and potassium tetrakis(4‐chlorophenyl)borate (KTpClPB) in the preparation of solid contact potassium‐ion selective electrodes (K+‐ISEs). Partly carboxylated PVC (PVC‐COOH) and a fully charged polyanion, sodium poly(4‐styrenesulfonate) (NaPSS), were used, culminating in the fabrication of three‐component ion‐selective membranes (ISMs). The comparison with a PVC‐based ISM showed significantly reduced potential drifts during conditioning (from ∼1.3 to ∼0.2 mV/h) and a constant drift rate. Reduced drift is attributed to the presence of counter‐charges in the polymer and the large molecular weight of the polyanions, therefore decreasing the leaching of the components resulting in degradation of the membrane. The ISEs utilizing the hydrophilic and highly charged NaPSS as the polymer matrix exhibit similar water layer formation compared to the PVC‐based ISEs, and maintained a sensitivity of 54 ± 1 mV/dec and a selectivity over sodium of −3.1 (log ) after 1 week in solution, suggesting an alternative approach to the standard membrane preparation protocol.