Milou Noltes

Ms. Milou Noltes

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2023 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
MNMilou Noltes
Milou Noltes
MBMaximilian Bader
Maximilian Bader
MMMadelon J. H. Metman
Madelon J. H. Metman
JVJasper Vonk
Jasper Vonk
PSPieter J. Steinkamp
Pieter J. Steinkamp
SKSchelto Kruijff
Schelto Kruijff
Purpose: Patient-tailored management of thyroid nodules requires improved risk of malignancy stratification by accurate preoperative nodule assessment, aiming to personalize decisions concerning diagnostics and treatment. Here, we perform an exploratory pilot study to identify possible patterns on multispectral optoacoustic tomography (MSOT) for thyroid malignancy stratification. For the first time, we directly correlate MSOT images with histopathology data on a detailed level. Methods: We use recently enhanced data processing and image reconstruction methods for MSOT to provide next-level image quality by means of improved spatial resolution and spectral contrast. We examine optoacoustic features in thyroid nodules associated with vascular patterns and correlate these directly with reference histopathology. Results: Our methods show the ability to resolve blood vessels with diameters of 250 μm at depths of up to 2 cm. The vessel diameters derived on MSOT showed an excellent correlation (R2-score of 0.9426) with the vessel diameters on histopathology. Subsequently, we identify features of malignancy observable in MSOT, such as intranodular microvascularity and extrathyroidal extension verified by histopathology. Despite these promising features in selected patients, we could not determine statistically relevant differences between benign and malignant thyroid nodules based on mean oxygen saturation in thyroid nodules. Thus, we illustrate general imaging artifacts of the whole field of optoacoustic imaging that reduce image fidelity and distort spectral contrast, which impedes quantification of chromophore presence based on mean concentrations. Conclusion: We recommend examining optoacoustic features in addition to chromophore quantification to rank malignancy risk. We present optoacoustic images of thyroid nodules with the highest spatial resolution and spectral contrast to date, directly correlated to histopathology, pushing the clinical translation of MSOT.

31 July 2019 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
MNMilou Noltes
Milou Noltes
SKSchelto Kruijff
Schelto Kruijff
WNWalter Noordzij
Walter Noordzij
ETEef D. Telenga
Eef D. Telenga
David Vállez GarcíaDavid Vállez García
David Vállez García
ABAdrienne Brouwers
Adrienne Brouwers
To evaluate the optimal tracer uptake time, the minimal amount of radioactivity and the inter-observer agreement for 11C-choline positron emission tomography/computed tomography (PET/CT) in patients with primary hyperparathyroidism (pHPT). Twenty-one patients with biochemically proven pHPT were retrospectively studied after injection of 6.3 ± 1.2 MBq/kg 11C-choline. PET data of the first nine patients, scanned for up to 60 min, were reconstructed in 10-min frames from 10- to 60-min postinjection (p.i.), mimicking varying 11C-choline uptake times. Parathyroid adenoma to background contrast ratios were calculated and compared, using standardized uptake values (SUVs). Data was reconstructed with varying scan durations (1, 2.5, 5, and 10 min) at 20–30-min p.i. (established optimal uptake time), mimicking less administered radioactivity. To establish the minimal required radioactivity, the SUVs in the shorter scan durations (1, 2.5, and 5 min) were compared to the 10-min scan duration to determine whether increased variability and/or statistical differences were observed. Four observers analyzed the 11C-choline PET/CT in four randomized rounds for all patients. SUVpeak of the adenoma decreased from 30 to 40 p.i. onwards. All adenoma/background contrast ratios did not differ from 20- to 30-min p.i. onwards. The SUVs of adenoma in the scan duration of 1, 2.5, and 5 min all differed significantly from the same SUV in the 10-min scan duration (all p = 0.012). However, the difference in absolute SUV adenoma values was well below 10% and therefore not considered clinically significant. The inter-observer analysis showed that the Fleiss’ kappa of the 1-min scan were classified as “moderate,” while these values were classified as “good” in the 2.5-, 5-, and 10-min scan duration. Observers scored lower certainty scores in the 1- and 2.5-min scans compared to the 5- and 10-min scan durations. The optimal time to start PET/CT scanning in patients with pHPT is 20 min after mean injection of 6.3 MBq/kg 11C-choline, with a recommended scan duration of at least 5 min. Alternatively, the radioactivity dose can be lowered by 50% while keeping a 10-min scan duration without losing the accuracy of 11C-choline PET/CT interpretation.

10 September 2018 in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
Verified
Journal Article
Open access
PDF file
GHGijs Thomas Hovenkamp
Gijs Thomas Hovenkamp
TOTycho Joan Olgers
Tycho Joan Olgers
RWRemco Robert Wortel
Remco Robert Wortel
MNMilou Noltes
Milou Noltes
BDBert Dercksen
Bert Dercksen
JMJan Cornelis ter Maaten
Jan Cornelis ter Maaten
A thorough handover in the emergency department (ED) is of great importance for improving the quality and safety in the chain of care. The satisfaction of handover may reflect the quality of handover. Research to discover the variables influencing the satisfaction of handovers is scarce. The goal of this study was to determine the factors influencing the satisfaction regarding handovers from ambulance and ED nurses. We performed a prospective observational study in the University Medical Center of Groningen. Data regarding prehospital-hospital handovers has been collected by observing handovers and assessing patient chart information. Data regarding the satisfaction has been collected with a questionnaire including a 5-point scale for the level of satisfaction. In total, 97 handovers were observed and 97 ambulance nurses and 89 ED nurses completed the questionnaire. The satisfaction of ambulance nurses showed a negative correlation with the waiting time prior to handover (r = −.287, p = .004) and a positive correlation with the presence of a physician in the receiving team (r = .224, p = .028). The satisfaction of ED nurses showed a positive correlation with the use of the ABCDE (r = .288, p = .006) and AMPLE instrument (r = .208, p = .050). The satisfaction of ambulance and ED nurses as sender or receiver of the handover is determined by different factors. The satisfaction of ambulance nurses is mainly affected by the waiting time and presence of a physician, while the satisfaction of ED nurses is affected by the use of handover instruments and the completeness of medical information.

23 March 2022 in VideoEndocrinology™
Verified
Journal Article
Open access
MNMilou Noltes
Milou Noltes
MMMadelon J.H. Metman
Madelon J.H. Metman
LJLiesbeth Jansen
Liesbeth Jansen
EPEmma W.M. Peeperkorn
Emma W.M. Peeperkorn
AEAnton F. Engelsman
Anton F. Engelsman
SKSchelto Kruijff
Schelto Kruijff
Introduction: Postoperative hypoparathyroidism is one of the most common complications after total thyroidectomy. In recent years, several techniques have been employed, trying to save parathyroid glands during thyroid surgery, such as autofluorescence and indocyanine green (ICG) angiography. In this study, we present a systematic approach to a parathyroid function saving total thyroidectomy using autofluorescence and quantified ICG angiography. Materials and Methods: Step-by-step video demonstration of a total thyroidectomy for thyroid cancer utilizing parathyroid autofluorescence and ICG angiography. Results: A systematic step-wise approach to a total thyroidectomy using autofluorescence and quantified ICG angiography is demonstrated. The set moments of deployment, settings of the camera, and a standardized workflow model for parathyroid autofluorescence and ICG angiography are noted. Conclusion: A systematic approach to parathyroid autofluorescence and quantified ICG angiography during total thyroidectomy may eventually guide the surgeon in early identification of the parathyroid glands and the need for parathyroid autotransplantation, thereby predicting and preventing postoperative hypoparathyroidism. The authors have no related personal conflicts of interest to declare that could be perceived as prejudicing the impartiality of the research reported. For this study, the Quest Spectrum was used. The authors have no conflicts with this or any other commercial entity. This research did not receive any specific grant from any funding agency in the public or commercial sector. Runtime of video: 9 mins 59 secs This video was presented at the Third Symposium on Parathyroid Fluorescence 2021.

8 March 2022 in Life
Verified
Journal Article
Open access
PDF file
EFEline Anne Feitsma
Eline Anne Feitsma
HSHugo Schouw
Hugo Schouw
MNMilou Noltes
Milou Noltes
WHWido Heeman
Wido Heeman
WKWendy Kelder
Wendy Kelder
SKSchelto Kruijff
Schelto Kruijff
Background: Postoperative hypoparathyroidism is the most common complication after total thyroidectomy. Over the past years, optical imaging techniques, such as parathyroid autofluorescence, indocyanine green (ICG) angiography, and laser speckle contrast imaging (LSCI) have been employed to save parathyroid glands during thyroid surgery. This study provides an overview of the utilized methods of the optical imaging techniques during total thyroidectomy for parathyroid gland identification and preservation. Methods: PUBMED, EMBASE and Web of Science were searched for studies written in the English language utilizing parathyroid autofluorescence, ICG-angiography, or LSCI during total thyroidectomy to support parathyroid gland identification or preservation. Case reports, reviews, meta-analyses, animal studies, and post-mortem studies were excluded after the title and abstract screening. The data of the studies were analyzed qualitatively, with a focus on the methodologies employed. Results: In total, 59 articles were included with a total of 6190 patients. Overall, 38 studies reported using parathyroid autofluorescence, 24 using ICG-angiography, and 2 using LSCI. The heterogeneity between the utilized methodology in the studies was large, and in particular, regarding study protocols, imaging techniques, and the standardization of the imaging protocol. Conclusion: The diverse application of optical imaging techniques and a lack of standardization and quantification leads to heterogeneous conclusions regarding their clinical value. Worldwide consensus on imaging protocols is needed to establish the clinical utility of these techniques for parathyroid gland identification and preservation.

8 October 2020 in Laryngoscope Investigative Otolaryngology
Verified
Journal Article
Open access
PDF file
MNMilou Noltes
Milou Noltes
SBStephan Brands
Stephan Brands
RDRudi A.J.O. Dierckx
Rudi A.J.O. Dierckx
PJPieter L. Jager
Pieter L. Jager
WKWendy Kelder
Wendy Kelder
SKSchelto Kruijff
Schelto Kruijff
Objective: The aim of this study was to determine the adherence to consensus guidelines on preoperative imaging of patients with primary hyperparathyroidism (pHPT) in real local practice.Methods: This was a retrospective multicenter cohort study of 411 patients undergoing parathyroidectomy for pHPT from 2007 to 2017 in three referral centers.Results: In 286/411 patients (69%) the preoperative imaging workup adhered to guidelines (utilizing ultrasound and parathyroid scintigraphy). In patients in whom guidelines were followed 63% were discharged within one day versus 37% in whom guidelines were not followed (P < .0005). The use of a bimodality imaging workup, starting with ultrasound and parathyroid scintigraphy followed by imaging upscaling aiming for anatomical and functional concordance, was a predictor for the performance of a minimally invasive parathyroidectomy (OR 4.098, 95% CI 2.296‐7.315, P < .0005).Conclusion: The level of compliance to preoperative imaging guidelines is suboptimal in this population. Patients in whom adherence was achieved showed a shorter length of stay. More education of physicians is required regarding the appropriate preoperative imaging workup in pHPT.Level of evidence: 2b (individual cohort study).