Chiwan Koo

Prof. Chiwan Koo

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CKChiwan Koo
Chiwan Koo
MMMartha Malapi-Wight
Martha Malapi-Wight
HKHyun Soo Kim
Hyun Soo Kim
OCOsman S. Cifci
Osman S. Cifci
VVVanessa L. Vaughn-Diaz
Vanessa L. Vaughn-Diaz
Arum HanArum Han
Arum Han
Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR) process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon) of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25×16×8 cm3 in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample.

30 December 2014 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
CKChiwan Koo
Chiwan Koo
BLBrittany E. LeBlanc
Brittany E. LeBlanc
MKMichael Kelley
Michael Kelley
HFHannah E. Fitzgerald
Hannah E. Fitzgerald
Gregory HuffGregory Huff
Gregory Huff
Arum HanArum Han
Arum Han
A nontoxic liquid metal, such as eutectic gallium-indium (EGaIn) alloy, has been used to develop tunable radio frequency (RF) components, such as antennas, inductors, or capacitors, for enabling large tunable range, better linearity, and low loss, using fluidic displacement of the liquid metal. However, EGaIn residue, due to its fast oxidation, limits multiple movement of the EGaIn in the reconfigurable RF components. This paper focuses on the use of surfactants, carrier liquids, and microchannel coating materials that minimize EGaIn fragmentation and EGaIn residues on poly(dimethylsiloxane) (PDMS)-based microfluidic channels during repeated actuation of an EGaIn plug. Using a combination of carrier liquids and microchannel coating materials to minimize EGaIn from leaving residues on the PDMS microfluidic channel, a microstrip transmission line switch as a proof-of-concept reconfigurable RF application using the EGaIn plug is demonstrated. It is switched ON<;4 dB and OFF with a loss of <;18 dB over the frequency range between 4 and 15 GHz.

22 September 2015 in International Neurourology Journal
Verified
Journal Article
Open access
PDF file
MDMathias Naangmenkpeong Dakurah
Mathias Naangmenkpeong Dakurah
CKChiwan Koo
Chiwan Koo
WCWonseok Choi
Wonseok Choi
YJYeun-Ho Joung
Yeun-Ho Joung
The loss of urinary bladder control/sensation, also known as urinary incontinence (UI), is a common clinical problem in autistic children, diabetics, and the elderly. UI not only causes discomfort for patients but may also lead to kidney failure, infections, and even death. The increase of bladder urine volume/pressure above normal ranges without sensation of UI patients necessitates the need for bladder sensors. Currently, a catheter-based sensor is introduced directly through the urethra into the bladder to measure pressure variations. Unfortunately, this method is inaccurate because measurement is affected by disturbances in catheter lines as well as delays in response time owing to the inertia of urine inside the bladder. Moreover, this technique can cause infection during prolonged use; hence, it is only suitable for short-term measurement. Development of discrete wireless implantable sensors to measure bladder volume/pressure would allow for long-term monitoring within the bladder, while maintaining the patient's quality of life. With the recent advances in microfabrication, the size of implantable bladder sensors has been significantly reduced. However, microfabricated sensors face hostility from the bladder environment and require surgical intervention for implantation inside the bladder. Here, we explore the various types of implantable bladder sensors and current efforts to solve issues like hermeticity, biocompatibility, drift, telemetry, power, and compatibility issues with popular imaging tools such as computed tomography and magnetic resonance imaging. We also discuss some possible improvements/emerging trends in the design of an implantable bladder sensor.

3 December 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
SKSUNGIL KIM
SUNGIL KIM
JKJeongtae Kim
Jeongtae Kim
YJYeun-Ho Joung
Yeun-Ho Joung
JCJiyeon Choi
Jiyeon Choi
CKChiwan Koo
Chiwan Koo
We present a rapid and highly reliable glass (fused silica) microfluidic device fabrication process using various laser processes, including maskless microchannel formation and packaging. Femtosecond laser assisted selective etching was adopted to pattern microfluidic channels on a glass substrate and direct welding was applied for local melting of the glass interface in the vicinity of the microchannels. To pattern channels, a pulse energy of 10 μJ was used with a scanning speed of 100 mm/s at a pulse repetition rate of 500 kHz. After 20–30 min of etching in hydrofluoric acid (HF), the glass was welded with a pulse energy of 2.7 μJ and a speed of 20 mm/s. The developed process was as simple as drawing, but powerful enough to reduce the entire production time to an hour. To investigate the welding strength of the fabricated glass device, we increased the hydraulic pressure inside the microchannel of the glass device integrated into a custom-built pressure measurement system and monitored the internal pressure. The glass device showed extremely reliable bonding by enduring internal pressure up to at least 1.4 MPa without any leakage or breakage. The measured pressure is 3.5-fold higher than the maximum internal pressure of the conventional polydimethylsiloxane (PDMS)–glass or PDMS–PDMS bonding. The demonstrated laser process can be applied to produce a new class of glass devices with reliability in a high pressure environment, which cannot be achieved by PDMS devices or ultraviolet (UV) glued glass devices.

8 October 2019 in Micro and Nano Systems Letters
Verified
Journal Article
Open access
PDF file
SKSUNGIL KIM
SUNGIL KIM
JKJeongtae Kim
Jeongtae Kim
YJYeun-Ho Joung
Yeun-Ho Joung
SASanghoon Ahn
Sanghoon Ahn
JCJiyeon Choi
Jiyeon Choi
CKChiwan Koo
Chiwan Koo
We present the selective laser-induced etching (SLE) process and design guidelines for the fabrication of three-dimensional (3D) microfluidic channels in a glass. The SLE process consisting of laser direct patterning and wet chemical etching uses different etch rates between the laser modified area and the unmodified area. The etch selectivity is an important factor for the processing speed and the fabrication resolution of the 3D structures. In order to obtain the maximum etching selectivity, we investigated the process window of the SLE process: the laser pulse energy, pulse repetition rate, and scan speed. When using potassium hydroxide (KOH) as a wet etchant, the maximum etch rate of the laser-modified glass was obtained to be 166 μm/h, exhibiting the highest selectivity about 333 respect to the pristine glass. Based on the optimized process window, a 3D microfluidic channel branching to three multilayered channels was successfully fabricated in a 4 mm-thick glass. In addition, appropriate design guidelines for preventing cracks in a glass and calibrating the position of the dimension of the hollow channels were studied.

24 April 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
WLWhitney Longsine-Parker
Whitney Longsine-Parker
HWHan Wang
Han Wang
CKChiwan Koo
Chiwan Koo
JKJeongyun Kim
Jeongyun Kim
BKBeomjoon Kim
Beomjoon Kim
Arum HanArum Han
Arum Han
A microfluidic device that simultaneously applies the conditions required for microelectroporation and microsonoporation in a flow-through scheme toward high-efficiency and high-throughput molecular delivery into mammalian cells is presented. This multi-modal poration microdevice using simultaneous application of electric field and ultrasonic wave was realized by a three-dimensional (3D) microelectrode scheme where the electrodes function as both electroporation electrodes and cell flow channel so that acoustic wave can be applied perpendicular to the electric field simultaneously to cells flowing through the microfluidic channel. This 3D microelectrode configuration also allows a uniform electric field to be applied while making the device compatible with fluorescent microscopy. It is hypothesized that the simultaneous application of two different fields (electric field and acoustic wave) in perpendicular directions allows formation of transient pores along two axes of the cell membrane at reduced poration intensities, hence maximizing the delivery efficiency while minimizing cell death. The microfluidic electro-sonoporation system was characterized by delivering small molecules into mammalian cells, and showed average poration efficiency of 95.6% and cell viability of 97.3%. This proof of concept result shows that by combining electroporation and sonoporation together, significant improvement in molecule delivery efficiency could be achieved while maintaining high cell viability compared to electroporation or sonoporation alone. The microfluidic electro-sonoporation device presented here is, to the best of our knowledge, the first multi-modal cell poration device using simultaneous application of electric field and ultrasonic wave. This new multi-modal cell poration strategy and system is expected to have broad applications in delivery of small molecule therapeutics and ultimately in large molecule delivery such as gene transfection applications where high delivery efficiency and high viability are crucial.