Karl Woldum Tordrup

Dr. Karl Woldum Tordrup

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2008 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
KTKarl Woldum Tordrup
Karl Woldum Tordrup
ANAntonio Negretti
Antonio Negretti
KMKlaus Moelmer
Klaus Moelmer
We propose to use a single mesoscopic ensemble of trapped polar molecules for quantum computing. A “holographic quantum register” with hundreds of qubits is encoded in collective excitations with definite spatial phase variations. Each phase pattern is uniquely addressed by optical Raman processes with classical optical fields, while one- and two-qubit gates and qubit readout are accomplished by transferring the qubit states to a stripline microwave cavity field and a Cooper pair box where controllable two-level unitary dynamics and detection is governed by classical microwave fields.

12 February 2008 in Physical Review A
Verified
Journal Article
Closed access
PDF file
KTKarl Woldum Tordrup
Karl Woldum Tordrup
KMKlaus Mølmer
Klaus Mølmer
We propose to encode quantum information in rotational excitations in a molecular ensemble. Using a stripline cavity field for quantum-state transfer between the molecular ensemble and a Cooper-pair-box two-level system, our proposal offers a linear scaling of the number of qubits in our register with the number of rotationally excited states available in the molecules.

1 May 2017 in Renewable Energy
Verified
Journal Article
Closed access
KTKarl Woldum Tordrup
Karl Woldum Tordrup
SPSøren Erbs Poulsen
Søren Erbs Poulsen
HBH. Bjørn
H. Bjørn

21 February 2022 in Water
Verified
Journal Article
Open access
PDF file
Theis AndersenTheis Andersen
Theis Andersen
SPSøren Erbs Poulsen
Søren Erbs Poulsen
KTKarl Woldum Tordrup
Karl Woldum Tordrup
This paper presents a multifunctional full-scale demonstration road, the Climate Road, which combines climate adaptation and mitigation in a single system. The Climate Road is located at Hedensted, Denmark and is 50 m long and 8 m wide, and the depth of the roadbed is 1 m. Half of the Climate Road, i.e., 25 m, is paved with permeable asphalt and the remaining 25 m with traditional asphalt. All surface water drains into the roadbed, which stores up to 120 m3 of water, either directly through the permeable asphalt or by drain grates. In addition, 800 m of geothermal pipes are embedded in the roadbed, distributed over four 200 m w-loops, two buried 1 m below the asphalt and two similar loops at 0.5 m depth. The Climate Road was tested from May 2019 to May 2021. In the project period, a total precipitation value of 1654 mm was recorded, the mean temperature was 9.3 °C and the most intense rainfall was 40.3 mm/30 min. The long-term infiltration performance of the permeable asphalt shows that the overall infiltration capacity slowly reduces. The reduction can be hindered, but not completely prevented, with annual restorative cleaning. After two years of operation, the Climate Road still, by a large margin, fulfils the recommendations of the infiltration capacity of 97.2 mm/h for the vast majority of the road section. The total volume reduction capacity is estimated to be between 15 and 30%. Based on an analysis of 61 single rain events, the event detention time is found to range between 10 and 130 min, with an average of 35 min. During the project period, the Climate Road produced a total of 98 MWh for a nearby kindergarten, with an average coefficient of performance (COP) of 3.1.

20 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
SPSøren Erbs Poulsen
Søren Erbs Poulsen
Theis AndersenTheis Andersen
Theis Andersen
KTKarl Woldum Tordrup
Karl Woldum Tordrup
This paper proposes and demonstrates, in full scale, a novel type of energy geostructure (“the Climate Road”) that combines a ground-source heat pump (GSHP) with a sustainable urban drainage system (SUDS) by utilizing the gravel roadbed simultaneously as an energy source and a rainwater retarding basin. The Climate Road measures 50 m × 8 m × 1 m (length, width, depth, respectively) and has 800 m of geothermal piping embedded in the roadbed, serving as the heat collector for a GSHP that supplies a nearby kindergarten with domestic hot water and space heating. Model analysis of operational data from 2018–2021 indicates sustainable annual heat production levels of around 0.6 MWh per meter road, with a COP of 2.9–3.1. The continued infiltration of rainwater into the roadbed increases the amount of extractable heat by an estimated 17% compared to the case of zero infiltration. Using the developed model for scenario analysis, we find that draining rainwater from three single-family houses and storing 30% of the annual heating consumption in the roadbed increases the predicted extractable energy by 56% compared to zero infiltration with no seasonal energy storage. The Climate Road is capable of supplying three new single-family houses with heating, cooling, and rainwater management year-round.

2 November 2020 in Quarterly Journal of Engineering Geology and Hydrogeology
Verified
Journal Article
Closed access
DCD. Cerra
D. Cerra
MPMaria Alberdi Pagola
Maria Alberdi Pagola
Theis AndersenTheis Andersen
Theis Andersen
KTKarl Woldum Tordrup
Karl Woldum Tordrup
SPSøren Erbs Poulsen
Søren Erbs Poulsen
We assess the feasibility of a collective district heating and cooling network based on a foundation pile heat exchanger in a new urban area in Vejle, Denmark. A thermogeological model for the area is developed based on geophysical investigations and borehole information. In tandem with a building energy demand model, the subsurface thermal properties serve as the input for a newly developed computational temperature model for collective heating and cooling with energy piles. The purpose of the model is to estimate the long-term performance and maximum liveable area that the energy piles are able to support. We consider two case studies where residential and office buildings dominate the building mass. We find that three to four floors can be supplied with heating and cooling from the energy piles, depending on the use and design of the buildings.