Charles Pontonnier

Dr. Charles Pontonnier

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2013 in Journal on Multimodal User Interfaces
Verified
Journal Article
Closed access
PDF file
CPCharles Pontonnier
Charles Pontonnier
GDGeorges Dumont
Georges Dumont
ASAfshin Samani
Afshin Samani
PMPascal Madeleine
Pascal Madeleine
MBMarwan Badawi
Marwan Badawi

21 January 2019 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
AMAntoine Muller
Antoine Muller
CPCharles Pontonnier
Charles Pontonnier
PPPierre Puchaud
Pierre Puchaud
GDGeorges Dumont
Georges Dumont

1 January 2020 in Applied Ergonomics
Verified
Journal Article
Closed access
AMAntoine Muller
Antoine Muller
CPCharles Pontonnier
Charles Pontonnier
XRXavier Robert-Lachaine
Xavier Robert-Lachaine
GDGeorges Dumont
Georges Dumont
APA. Plamondon
A. Plamondon

27 December 2019 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
PPP. Puchaud
P. Puchaud
CSChristophe Sauret
Christophe Sauret
AMAntoine Muller
Antoine Muller
NBN. Bideau
N. Bideau
GDGeorges Dumont
Georges Dumont
CPCharles Pontonnier
Charles Pontonnier
Medical images are not typically included in protocol of motion laboratories. Thus, accurate scaling of musculoskeletal models from optoelectronic data are important for any biomechanical analysis. The aim of the current study was to identify a scaling method based on optoelectronic data, inspired from literature, which could offer the best trade-off between accurate geometrical parameters (segment lengths, orientation of joint axes, marker coordinates) and consistent inverse kinematics outputs (kinematic error, joint angles). The methods were applied on 26 subjects and assessed with medical imagery building EOS-based models, considered as a reference. The main contribution of this paper is to show that the marker-based scaling followed by an optimisation of orientation joint axes and markers local coordinates, gives the most consistent scaling and joint angles with EOS-based models. Thus, when a non-invasive mean with an optoelectronic system is considered, a marker-based scaling is preliminary needed to get accurate segment lengths and to optimise joint axes and marker local coordinates to reduce kinematic errors.

4 November 2013 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Closed access
CPCharles Pontonnier
Charles Pontonnier
ASAfshin Samani
Afshin Samani
MBMarwan Badawi
Marwan Badawi
PMPascal Madeleine
Pascal Madeleine
GDGeorges Dumont
Georges Dumont
Nowadays the process of workstation design tends to include assessment steps in a virtual environment (VE) to evaluate the ergonomic features. These approaches are cost-effective and convenient since working directly on the digital mock-up in a VE is preferable to constructing a real physical mock-up in a real environment (RE). This study aimed at understanding the ability of a VR-based assembly tasks simulator to evaluate physical risk factors in ergonomics. Sixteen subjects performed simplified assembly tasks in RE and VE. Motion of the upper body and five muscle electromyographic activities were recorded to compute normalized and averaged objective indicators of discomfort, that is, rapid upper limb assessment score, averaged muscle activations, and total task time. Rated perceived exertion (RPE) and a questionnaire were used as subjective indicators of discomfort. The timing regime and complexity of the assembly tasks were investigated as within-subject factors. The results revealed significant differences between measured indicators in RE and VE. While objective measures indicated lower activity and exposure in VE, the subjects experienced more discomfort than in RE. Fairly good correlation levels were found between RE and VE for six of the objective indicators. This study clearly demonstrates that ergonomic studies of assembly tasks using VR are still challenging. Indeed, objective and subjective measurements of discomfort that are usually used in ergonomics to minimize the risks of work-related musculoskeletal disorders development exhibit opposite trends in RE and VE. Nevertheless, the high level of correlation found during this study indicates that the VR-based simulator can be used for such assessments.

1 May 2014 in Applied Ergonomics
Verified
Journal Article
Closed access
CPCharles Pontonnier
Charles Pontonnier
Mark de ZeeMark de Zee
Mark de Zee
ASAfshin Samani
Afshin Samani
GDGeorges Dumont
Georges Dumont
PMPascal Madeleine
Pascal Madeleine