Andrew Fix

Mr. Andrew Fix

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2022 in Energy & Environmental Science
Verified
Journal Article
Closed access
PDF file
ARAkshay K. Rao
Akshay K. Rao
AFAndrew Fix
Andrew Fix
YYYun Chi Yang
Yun Chi Yang
DWDavid M Warsinger
David M Warsinger
Atmospheric water harvesting (AWH) is a rapidly emerging approach for decentralized water production, but current technology is limited by trade-offs between energy consumption and yield. The field lacks a common basis to compare different AWH technologies and a robust understanding of the performance impacts of water recovery, desorption humidity (for sorbent systems), and realistic component-level efficiencies. By devising a set of unifying assumptions and consistent parameters across technologies, we provide the first fair thermodynamic comparison over a broad range of environmental conditions. Using 2nd law analysis, or least work, we study the maximum efficiency for common open system AWH methods – fog nets, dew plates, membrane-systems, and sorption processes – to identify the process performance limits. We find that the thermodynamic minimum for any AWH process is anywhere from 0× (relative humidity (RH) ≥ 100%) to upwards of 250× (RH < 10%) the minimum energy requirement of seawater desalination. Sorbents have a particular niche in colder (T < 310 K), arid regions (<6 g kg−1). Membrane-systems are best at low relative humidity and the region of applicability is strongly affected by vacuum pumping efficiency. Dew harvesting is best at higher humidity (RH > 40%) and fog harvesting is optimal when super-saturated conditions exist. Increasing efficiency at the component-level, particularly for vacuum pumps and condensers, may be the most promising avenue for improvement. Enabled by peta-scale computing, our findings use geographical and parametric mapping to provide a framework for technology deployment and energy-optimization.

25 September 2024 in Energy
Verified
Journal Article
Closed access
LGLei Gao
Lei Gao
AFAndrew Fix
Andrew Fix
TSTamoy Seabourne
Tamoy Seabourne
YPYong Pei
Yong Pei
PAPatrick Adegbaye
Patrick Adegbaye
RRReinhard Radermacher
Reinhard Radermacher

31 August 2023 in Energy Conversion and Management
Verified
Journal Article
Closed access
MMMaisha Mumtaz
Maisha Mumtaz
BPBryan C. Pamintuan
Bryan C. Pamintuan
AFAndrew Fix
Andrew Fix
JBJames E. Braun
James E. Braun
DWDavid M Warsinger
David M Warsinger

7 December 2022 in Energy Conversion and Management
Verified
Journal Article
Closed access
AFAndrew Fix
Andrew Fix
SGShivam Gupta
Shivam Gupta
JBJames E. Braun
James E. Braun
DWDavid M Warsinger
David M Warsinger

28 January 2024 in Energy Conversion and Management
Verified
Journal Article
Closed access
JOJinwoo Oh
Jinwoo Oh
AFAndrew Fix
Andrew Fix
DZDavide Ziviani
Davide Ziviani
JBJames E. Braun
James E. Braun
DWDavid M Warsinger
David M Warsinger

22 March 2022 in Membranes
Verified
Journal Article
Open access
PDF file
ACAjay Sekar Chandrasekaran
Ajay Sekar Chandrasekaran
AFAndrew Fix
Andrew Fix
DWDavid M Warsinger
David M Warsinger
Traditional air conditioning systems use a significant amount of energy on dehumidification by condensing water vapor out from the air. Membrane-based air conditioning systems help overcome this problem by avoiding condensation and treating the sensible and latent loads separately, using membranes that allow water vapor transport, but not air (nitrogen and oxygen). In this work, a computational fluid dynamics (CFD) model has been developed to predict the heat and mass transfer and concentration polarization performance of a novel active membrane-based energy exchanger (AMX). The novel design is the first of its kind to integrate both vapor removal via membranes and air cooling into one device. The heat transfer results from the CFD simulations are compared with common empirical correlations for similar geometries. The performance of the AMX is studied over a broad range of operating conditions using the compared CFD model. The results show that strong tradeoffs result in optimal values for the channel length (0.6–0.8 m) and the ratio of coil diameter to channel height (~0.5). Water vapor transport is best if the flow is just past the turbulence transition around 3000–5000 Reynolds number. These trends hold over a range of conditions and dimensions.