Yousef H. M. Alghazali

Mr. Yousef H. M. Alghazali

Aachen University of Applied Sciences, Institute of Nano- and Biotechnologies (INB)
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
FVFarnoosh Vahidpour
Farnoosh Vahidpour
Yousef H. M. AlghazaliYousef H. M. Alghazali
Yousef H. M. Alghazali
SASevilay Akca
Sevilay Akca
GHGregor Hommes
Gregor Hommes
MSMichael Schöning
Michael Schöning
This work introduces a novel method for the detection of H2O2 vapor/aerosol of low concentrations, which is mainly applied in the sterilization of equipment in medical industry. Interdigitated electrode (IDE) structures have been fabricated by means of microfabrication techniques. A differential setup of IDEs was prepared, containing an active sensor element (active IDE) and a passive sensor element (passive IDE), where the former was immobilized with an enzymatic membrane of horseradish peroxidase that is selective towards H2O2. Changes in the IDEs’ capacitance values (active sensor element versus passive sensor element) under H2O2 vapor/aerosol atmosphere proved the detection in the concentration range up to 630 ppm with a fast response time (<60 s). The influence of relative humidity was also tested with regard to the sensor signal, showing no cross-sensitivity. The repeatability assessment of the IDE biosensors confirmed their stable capacitive signal in eight subsequent cycles of exposure to H2O2 vapor/aerosol. Room-temperature detection of H2O2 vapor/aerosol with such miniaturized biosensors will allow a future three-dimensional, flexible mapping of aseptic chambers and help to evaluate sterilization assurance in medical industry.

24 February 2022 in Foods
Verified
Journal Article
Open access
PDF file
FVFarnoosh Vahidpour
Farnoosh Vahidpour
EGEric Guthmann
Eric Guthmann
JAJulio Arreola
Julio Arreola
Yousef H. M. AlghazaliYousef H. M. Alghazali
Yousef H. M. Alghazali
TWTorsten Wagner
Torsten Wagner
MSMichael Schöning
Michael Schöning
In this study, an online multi-sensing platform was engineered to simultaneously evaluate various process parameters of food package sterilization using gaseous hydrogen peroxide (H2O2). The platform enabled the validation of critical aseptic parameters. In parallel, one series of microbiological count reduction tests was performed using highly resistant spores of B. atrophaeus DSM 675 to act as the reference method for sterility validation. By means of the multi-sensing platform together with microbiological tests, we examined sterilization process parameters to define the most effective conditions with regards to the highest spore kill rate necessary for aseptic packaging. As these parameters are mutually associated, a correlation between different factors was elaborated. The resulting correlation indicated the need for specific conditions regarding the applied H2O2 gas temperature, the gas flow and concentration, the relative humidity and the exposure time. Finally, the novel multi-sensing platform together with the mobile electronic readout setup allowed for the online and on-site monitoring of the sterilization process, selecting the best conditions for sterility and, at the same time, reducing the use of the time-consuming and costly microbiological tests that are currently used in the food package industry.

29 May 2022
Verified
Conference Paper
Closed access
FVFarnoosh Vahidpour
Farnoosh Vahidpour
Yousef H. M. AlghazaliYousef H. M. Alghazali
Yousef H. M. Alghazali
STSteffen Thies
Steffen Thies
GHGregor Hommes
Gregor Hommes
MSMichael J. Schoning
Michael J. Schoning
This paper presents a novel approach for the detection of hydrogen peroxide (H2O2) vapor at low concentrations and room temperature conditions, as these are often used for sterilization in medical industry. Interdigitated electrode structures (IDEs) have been fabricated on glass substrates by means of microfabrication techniques and Ti/Pt evaporation. Impedance spectroscopy is used for impedance measurements of the IDE structures in H2O2 atmosphere, which was provided by a glass bottle containing 20 mL of 35% w/w H2O2 (i.e., free evaporation in a confined space with stable and homogenous temperature). The sensor signal shows changes by varying the H2O2 concentrations inside the gas-tight glass bottle. Selectivity was achieved by means of the enzyme horse radish peroxidase. The detection of low concentrations of H2O2 gas at room temperature and in the aerosol phase is performed in this study for the first time, which paves the path towards on-line monitoring of H2O2 gas in aseptic processing.