Training with visual and auditory biofeedback, in patients with stroke, improved balance ability and asymmetric posture. We developed a new biofeedback training device to prevent falls and improve balance ability in patients with stroke. This device corrects motion errors by collecting the pressure information of patients in real-time. This randomized crossover study aimed to investigate the effect of this biofeedback training on the static balance ability and weight distribution symmetry index in 24 patients with chronic stroke. Pressure sensor-based vibrotactile biofeedback, visual biofeedback providing posture information, and standing without biofeedback were randomly applied for 1 d each with 24 h washout intervals to minimize adaptation. The static balance ability was measured for each biofeedback training type, and the weight distribution symmetry index was calculated using the collected weight-bearing rate data. The static balance ability and weight distribution symmetry index differed significantly according to the type of biofeedback training used. Post-hoc analysis revealed significant differences in the order of newly developed vibrotactile biofeedback, visual biofeedback, and standing without biofeedback. These findings provide evidence that pressure sensor-based vibrotactile biofeedback improves static balance ability and weight support rates by proposing better intervention for patients with chronic stroke in the clinical environment.
Since there are many different assessments related to gait speed, it is important to determine the concurrent validity of each measure so that they can be used interchangeably. Our study aimed to investigate the concurrent validity of gait speed measured by the 10 m walk test (10 MWT) and the gold standard gait analysis system, the GAITRite system, for people with chronic ankle instability (CAI). For 16 people with CAI, 4 evaluations of the 10 MWT and 4 evaluations of the GAITRite system were performed (a comfortable gait speed for 2 evaluations; a maximal gait speed for 2 evaluations). We used intraclass correlations [ICC (2,1), absolute agreement] and Bland–Altman plots to analyze the relationship between the gait speed of the two measures. The absolute agreement between the 10 MWT and the GAITRite system is at the comfortable gait speed [ICC = 0.66; p < 0.001)], and the maximal gait speed [ICC = 0.68; p < 0.001)] showed fair to good agreement. Both gait speeds had a proportional bias; the limit of agreement (LOA) was large (0.50 at the comfortable gait speed and 0.60 at the maximal gait speed). Regression-based Bland–Altman plots were created for the comfortable gait speed (R2 = 0.54, p < 0.001) and the maximal gait speed (R2 = 0.78, p < 0.001). The regression-based LOA ranged from 0.45 to 0.66 m/s for the comfortable gait speed and 1.09 to 1.37 m/s for the maximal gait speed. Our study suggests that it is undesirable to mix the 10 MWT and the GAITRite system gait speed measurements in people with CAI. Each measure should not be recorded by the same evaluation tool and referenced to normative data.
30 June 2020 in Physical Therapy Rehabilitation Science