Manfred Radmacher

Dr. Manfred Radmacher

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2000 in Biophysical Journal
Verified
Journal Article
Closed access
CRChristian Rotsch
Christian Rotsch
MRManfred Radmacher
Manfred Radmacher

25 September 1992 in Science
Verified
Journal Article
Closed access
PDF file
MRManfred Radmacher
Manfred Radmacher
RTR W Tillamnn
R W Tillamnn
MFM Fritz
M Fritz
HGH E Gaub
H E Gaub
Since its invention a few years ago, the atomic force microscope has become one of the most widely used near-field microscopes. Surfaces of hard samples are imaged routinely with atomic resolution. Soft samples, however, remain challenging. An overview is presented on the application of atomic force microscopy to organic samples ranging from thin ordered films at molecular resolution to living cells. Fundamental mechanisms of the image formation are discussed, and novel imaging modes are introduced that exploit different aspects of the tip-sample interaction for local measurements of the micromechanical properties of the sample. As examples, images of Langmuir-Blodgett films, which map the local viscoelasticity as well as the friction coefficient, are presented.

28 March 1994 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
PHP. K. Hansma
P. K. Hansma
JCJ. P. Cleveland
J. P. Cleveland
MRManfred Radmacher
Manfred Radmacher
DWD. A. Walters
D. A. Walters
PHP. E. Hillner
P. E. Hillner
VEV. Elings
V. Elings
Tapping mode atomic force microscopy in liquids gives a substantial improvement in imaging quality and stability over standard contact mode. In tapping mode the probe-sample separation is modulated as the probe scans over the sample. This modulation causes the probe to tap on the surface only at the extreme of each modulation cycle and therefore minimizes frictional forces that are present when the probe is constantly in contact with the surface. This imaging mode increases resolution and reduces sample damage on soft samples. For our initial experiments we used a tapping frequency of 17 kHz to image deoxyribonucleic acid plasmids on mica in water. When we imaged the same sample region with the same cantilever, the plasmids appeared 18 nm wide in contact mode and 5 nm in tapping mode.

1 January 1996 in Biophysical Journal
Verified
Journal Article
Closed access
MRManfred Radmacher
Manfred Radmacher
MFM. Fritz
M. Fritz
CKC.M. Kacher
C.M. Kacher
JCJ.P. Cleveland
J.P. Cleveland
PHP.K. Hansma
P.K. Hansma

15 May 1998 in Langmuir
Verified
Journal Article
Closed access
JDJan Domke
Jan Domke
MRManfred Radmacher
Manfred Radmacher

2 February 1999 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
CRChristian Rotsch
Christian Rotsch
KJKen Jacobson
Ken Jacobson
MRManfred Radmacher
Manfred Radmacher
The atomic force microscope (AFM) was employed to investigate the extension and retraction dynamics of protruding and stable edges of motile 3T3 fibroblasts in culture. Such dynamics closely paralleled the results of earlier studies employing video microscopy that indicated that the AFM force-mapping technique does not appreciably perturb these dynamics. Force scans permitted height determinations of active and stable edges. Whereas the profiles of active edges are flat with average heights of 0.4–0.8 μm, stable edges smoothly ascend to 2–3 μm within about 6 μm of the edge. In the region of the leading edge, the height fluctuates up to 50% (SD) of the mean value, much more than the stable edge; this fluctuation presumably reflects differences in underlying cytoskeletal activity. In addition, force mapping yields an estimate of the local Young’s modulus or modulus of elasticity (E, the cortical stiffness). This stiffness will be related to “cortical tension,” can be accurately calculated for the stable edges, and is ≈12 kPa in this case. The thinness of the leading edge precludes accurate estimation of the E values, but within 4 μm of the margin it is considerably smaller than that for stable edges, which have an upper limit of 3–5 kPa. Although blebbing cannot absolutely be ruled out as a mechanism of extension, the data are consistent with an actin polymerization and/or myosin motor mechanism in which the average material properties of the extending margin would be nearly constant to the edge. Because the leading edge is softer than the stable edge, these data also are consistent with the notion that extension preferentially occurs in regions of lower cortical tension.