Elsa Legris

Dr. Elsa Legris


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ELElsa Legris
Elsa Legris
JGJohn Galvin
John Galvin
SRSylvie Roux
Sylvie Roux
MGMarie Gomot
Marie Gomot
JAJean-Marie Aoustin
Jean-Marie Aoustin
David BakhosDavid Bakhos
David Bakhos
Adults with single sided deafness (SSD) have lost binaural function, which limits sound source localization, speech understanding in noise, and quality of life. For SSD patients, restoration of bilateral auditory input is possible only with a cochlear implant (CI). In this study, cortical auditory evoked potentials (CAEPs) and behavioral performance were measured in left-implanted (SSD-CI-L) and right-implanted (SSD-CI-R) patients before and after cochlear implantation. We hypothesized that improvements in behavioral performance would be accompanied by changes in CAEPs after cochlear implantation. Prospective longitudinal study. Tertiary referral center. Nine right-handed adult SSD CI patients participated in the study. CAEPs were recorded before cochlear implantation and at 6 and 12 months post-implantation. CAEPs were elicited using speech stimuli (/ba/) delivered in sound field at 70 dBA. Global field power (GFP) latency and amplitude were calculated for P1, N1 and P2 peaks at each test session. CAEP were analyzed at frontocentral (Cz) and temporal (P7, P8, T7 and T8) and mastoid electrodes (M1 and M2) contralateral to the CI ear. Behavioral measures (sentence recognition in noise, with and without spatial cues) were collected at the same test sessions as for CAEPs. Speech performance and CAEPs were also measured in a control group of normal-hearing (NH) subjects. While increased N1 amplitude was observed in the scalp potential maps for GFP and Cz for SSD-CI-L patients after implantation, the changes were not statistically significant. Peak CAEP amplitude at electrodes to contralateral to the CI ear increased after cochlear implantation for all SSD-CI patients, but significant increases were observed only for mastoid sites. Peak latencies for some components at temporal and mastoid sites remained significantly longer than for the NH control group, even after cochlear implantation. For SSD-CI-R patients, P2 peak amplitude for baseline GFP and Cz was significantly lower than for the NH control group. A significant improvement for speech understanding in noise was observed at 12 months post-implantation when speech was presented to the CI ear and noise to the non-implanted ear. After cochlear implantation, speech understanding significantly improved when speech and noise were spatially separated. The increased N1 amplitude for SSD-CI-L patients and the increased bilateral activation for all SSD-CI patients may reflect cortical reorganization and restoration of binaural function after one year of experience with the CI. However, because of the limited number of SSD patients, significant changes in cortical activity after cochlear implantation were often difficult to observe.

1 May 2021 in European Annals of Otorhinolaryngology, Head and Neck Diseases
Verified
Journal Article
Closed access
ELElsa Legris
Elsa Legris
JHJ. Henriques
J. Henriques
CAC. Aussedat
C. Aussedat
JAJ.-M. Aoustin
J.-M. Aoustin
MRM. Robier
M. Robier
DBD. Bakhos
D. Bakhos

15 March 2022 in Brain Sciences
Verified
Journal Article
Open access
PDF file
ELElsa Legris
Elsa Legris
JGJohn Galvin
John Galvin
YMYassine Mofid
Yassine Mofid
NANadia Aguillon-Hernandez
Nadia Aguillon-Hernandez
SRSylvie Roux
Sylvie Roux
David BakhosDavid Bakhos
David Bakhos
Background: For hearing-impaired individuals, hearing aids are clinically fit according to subjective measures of threshold and loudness. The goal of this study was to evaluate objective measures of loudness perception that might benefit hearing aid fitting. Method: Seventeen adult hearing aid users and 17 normal-hearing adults participated in the study. Outcome measures including categorical loudness scaling, cortical auditory evoked potentials (CAEPs), and pupillometry. Stimuli were 1-kHz tone bursts presented at 40, 60, and 80 dBA. Results: Categorical loudness scaling showed that loudness significantly increased with intensity for all participants (p < 0.05). For CAEPs, high intensity was associated with greater P1, N1, and P2 peak amplitude for all listeners (p < 0.05); a significant but small effect of hearing aid amplification was observed. For all participants, pupillometry showed significant effects of high intensity on pupil dilation (p < 0.05); there was no significant effect of hearing aid amplification. A Focused Principal Component analysis revealed significant correlations between subjective loudness and some of the objective measures. Conclusion: The present data suggest that intensity had a significant impact on loudness perception, CAEPs, and pupil response. The correlations suggest that pupillometry and/or CAEPs may be useful in determining comfortable amplification for hearing aids.

25 September 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ELElsa Legris
Elsa Legris
JGJohn Galvin
John Galvin
SRSylvie Roux
Sylvie Roux
JAJean-Marie Aoustin
Jean-Marie Aoustin
DBDavid Bakhos
David Bakhos
For patients with single-sided deafness (SSD), restoration of binaural function via cochlear implant (CI) has been shown to improve speech understanding in noise. The objective of this study was to investigate changes in behavioral performance and cortical auditory responses following cochlear implantation. Prospective longitudinal study. Tertiary referral center. Six adults with SSD were tested before and 12 months post-activation of the CI. Six normal hearing (NH) participants served as experimental controls. Speech understanding in noise was evaluated for various spatial conditions. Cortical auditory evoked potentials were recorded with /ba/ stimuli in quiet and in noise. Global field power and responses at Cz were analyzed. Speech understanding in noise significantly improved with the CI when speech was presented to the CI ear and noise to the normal ear (p<0.05), but remained poorer than that of NH controls (p<0.05). N1 peak amplitude measure in noise significantly increased after CI activation (p<0.05), but remained lower than that of NH controls (p<0.05) at 12 months. After 12 months of CI experience, cortical responses in noise became more comparable between groups. Binaural restoration in SSD patients via cochlear implantation improved speech performance noise and cortical responses. While behavioral performance and cortical auditory responses improved, SSD-CI outcomes remained poorer than that of NH controls in most cases, suggesting only partial restoration of binaural hearing.

1 November 2019 in European Annals of Otorhinolaryngology, Head and Neck Diseases
Verified
Journal Article
Closed access
ELElsa Legris
Elsa Legris
SRS. Roux
S. Roux
JAJ.-M. Aoustin
J.-M. Aoustin
JGJ. Galvin
J. Galvin
DBD. Bakhos
D. Bakhos