Omar M. Kotb

Omar M. Kotb


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
STSvetlana A. Tankovskaia
Svetlana A. Tankovskaia
OKOmar M. Kotb
Omar M. Kotb
ODOlga Aleksandrovna Dommes
Olga Aleksandrovna Dommes
SPSergey Paston
Sergey Paston

15 June 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
STSa Tankovskaia
Sa Tankovskaia
OKOmar M. Kotb
Omar M. Kotb
ODOa Dommes
Oa Dommes
SPSv Paston
Sv Paston

27 January 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
OFOmar F. Farag
Omar F. Farag
OKOmar M. Kotb
Omar M. Kotb
MGM. El Ghazaly
M. El Ghazaly
NENaglaa M. El-Sayed
Naglaa M. El-Sayed
The response of the modified GAFCHROMIC EBT2 radiochromic film to DC Oxygen glow discharge plasma was investigated using a flatbed scanner and an UV–Vis spectrophotometer. The film was modified by removing the polyester overlaminate, adhesive, and topcoat layers with a total thickness of 80 µm, and is now referred to as EBT2-M. The EBT2-M films were exposed to DC Oxygen plasma for different durations: 0, 0.5, 1, 2, 3, 4, 7, and 10 min. The exposed films exhibit coloration homogeneity with an average variation of (1.6 ± 0.3) × 10−4 pixel values/µm, irrespective of the applied exposure time. The pixel values of the red-and-green channels and weighted grayscale images decreased exponentially with different sensitivity amounts to $$\sim$$ ∼ 39.67, 49.69, and 42.11 min−1, respectively, as the exposure time increased. The two absorption peaks at 580 ± 4 nm and 632 ± 4 nm in the UV–Vis absorption spectra of the exposed GAFCHROMIC EBT2-M radiochromic films are increasing with increasing exposure time up to 4 min, thereafter saturated for prolonged exposure time. The integrated absorbance in the range from 400 to 700 nm is linearly correlated with the exposure time. The indirect and direct optical energy band gaps and Urbach energy of the modified GAFCHROMIC EBT2 film are weakly correlated with the exposure time. These findings suggest the utilization of the modified GAFCHROMIC EBT2 radiochromic film as a novel and simple technique for plasma diagnostics.

7 December 2023 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
OKOmar M. Kotb
Omar M. Kotb
ASAleksei N. Solovev
Aleksei N. Solovev
VSVyacheslav O. Saburov
Vyacheslav O. Saburov
VPVladimir I. Potetnya
Vladimir I. Potetnya
EKEkaterina V. Koryakina
Ekaterina V. Koryakina
AKAndrei D. Kaprin
Andrei D. Kaprin

25 April 2022 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
OKOmar M. Kotb
Omar M. Kotb
MGM. El Ghazaly
M. El Ghazaly
AMAmal Mohamed
Amal Mohamed
MIManar A. Ibrahim
Manar A. Ibrahim

24 May 2025 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
OKOmar M. Kotb
Omar M. Kotb
SESeham M. El-Marakby
Seham M. El-Marakby
NAN.I. Abu-Elsaad
N.I. Abu-Elsaad
DADoaa Abdelhameed
Doaa Abdelhameed
SISara H. Ibrahim
Sara H. Ibrahim
MAMohamed Ali
Mohamed Ali