Indoor air organic compounds were continuously monitored during 3 years in new and older homes which were voluntarily selected throughout countries. The levels of volatile organic compounds (VOCs) in the new homes decreased markedly after 1 year, and steady emissions of VOCs were obtained in the initial months. Formaldehyde and a-pinene related to wooden materials need a longer flushing period than the other compounds in the new homes. The levels of the indoor air organic compounds in the older homes showed no significant fluctuation during the 3-year period. Decreases of the indoor-produced compounds in the new homes did not depend upon the ventilation systems. The results indicate that the indoor-produced compounds in the new homes will be more influenced by the aging decreases of emission source strengths than ventilation systems. The quantitative information on the trend of the indoor air organic compound levels will be useful for the risk assessment of indoor exposure to those compounds, and also for Japanese IAQ guidelines. The initial levels of VOCs in the new homes decreased dramatically and were close to the mean values for the older homes after one year. The results suggest that steady emissions of VOCs are obtained within initial months. However, formaldehyde and a-pinene did not follow the trend for VOCs, particularly in the wooden framed houses. The results tend to suggest that formaldehyde and a-pinene related to wooden materials will need more long a flushing period than other compounds in the new homes. Decreasing tendency of indoor air organic compound levels in the new homes did not appear to show any dependency upon the ventilation systems over the whole period. Absence of data for ventilation rates in the houses dose not permit interpretation of the relation between ventilation rates and indoor air organic compound levels with statistical certainty, but the results suggest that indoor air organic compound levels in the homes will be more influenced by emission source strengths than ventilation systems. The levels of indoor air organic compounds in the new homes are sufficiently decreased according to the ageing decreases of organic compounds when the home is ventilated with adequate quantities.
The purpose of this study is to evaluate the effect of ventilation rate on work performance and perceived air quality through short-term laboratory experiments. The experiment was designed to simulate office work, and a laboratory space was modified using new finish materials to become a typical office space. High levels of volatile organic compounds (VOCs) were found in the exposure chamber, most probably originating from the new finishing materials that were present. Twenty-four subjects were divided into six groups that were randomly exposed to the three ventilation rates, 5, 10, and 20 l/s per person. The subjects performed work tasks three separate times for each ventilation rate over an 8-h exposure period. The work performance of the subjects logarithmically improved with increased ventilation rates, which was similar to the previous research findings. Statistical significance was found for addition task, text-typing task, and memorization task. Increased work performance in this experiment was slightly lower than the results of previous short-term laboratory experiments, yet remained higher than results of previous long-term field experiments. However, it was difficult to directly compare the results of this experiment with those of previous experiments, because of the higher concentration of VOC present in the office rooms and the learning effect associated with the repeated tasks. The results of this experiment show that ventilation had positive impacts on perceived air quality and work performance for the subjects tested. Work performance logarithmically increased by approximately 2.5-5% as ventilation rates were increased from 5 to 20 l/s per person. The positive effect of ventilation rate on work performance was shown to be limited at the low ventilation rate. The positive effects on work performance were at lower ventilation rates. The learning effect in repeated work performance tasks could increase the uncertainty of the work performance analysis in 8-h exposure period.
A 1.2 V 4 Gb DDR4 SDRAM is presented in a 30 nm CMOS technology. DDR4 SDRAM is developed to raise memory bandwidth with lower power consumption compared with DDR3 SDRAM. Various functions and circuit techniques are newly adopted to reduce power consumption and secure stable transaction. First, dual error detection scheme is proposed to guarantee the reliability of signals. It is composed of cyclic redundancy check (CRC) for DQ channel and command-address (CA) parity for command and address channel. For stable reception of high speed signals, a gain enhanced buffer and PVT tolerant data fetch scheme are adopted for CA and DQ respectively. To reduce the output jitter, the type of delay line is selected depending on data rate at initial stage. As a result, test measurement shows 3.3 Gb/s DDR operation at 1.14 V.