Yongzhen Bao

Yongzhen Bao


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
XLXiaochun Li
Xiaochun Li
XCXiaoguang Cao
Xiaoguang Cao
YYYingying Yu
Yingying Yu
YBYongzhen Bao
Yongzhen Bao
Purpose. The previous lab and clinical studies of the correlation between the ultraviolet B and age‐related cataract (ARC) did not reach in the universal agreement, especially in different morphological types of ARC. It is important to systemically summarize those previous data of epidemiological studies, which might penetrate the relevance between three morphological types of ARC, cortical, nuclear, and posterior capsular (PSC), with sunlight exposure. Methods. PubMed, Web of Science, CNKI, Embase, and Cochrane were searched online. Data were extracted and recalculated, and quality check was performed by hand. Review Manager was used to perform the fixed effects meta‐analysis on ARC and its morphological types. The highest exposed dose group was defined as the exposed group, and the lowest dose group as the control group as possible. Results. Finally, the number of analyzed studies was 31: 20 for ARC and twelve, eleven, and nine for the morphological types cortical, nuclear, and PSC, respectively. The pooled OR for ARC was 1.15 (range 1.00~43.78, 95% CI 1.09 to 1.21). The cortical cataract revealed a slightly higher risk, and pooled OR was 1.03 (range 0.67~2.91, 95% CI 1.02 to 1.03). But the pooled OR for nuclear and PSC were 1.00 (range 0.50~5.35, 95% CI 1.00 to 1.00) and 0.99 (range 0.57~1.87, 95% CI 0.95 to 1.01), respectively. Conclusions. The systemic analysis of epidemiological articles reported till now reveals a significantly increased risk of ARC for those exposed with more sunlight, especially the morphological type of cortical cataract.

1 January 2022 in BioMed Research International
Verified
Journal Article
Open access
PDF file
XLXiaochun Li
Xiaochun Li
XCXiaoguang Cao
Xiaoguang Cao
YBYongzhen Bao
Yongzhen Bao
Purpose. To compare the total corneal astigmatism (TCA) measured by IOLMaster 700 and Pentacam and to investigate the consistency of corneal keratometry (CK) measured by IOLMaster and Pentacam. Methods. Cataract patients were retrospectively enrolled in March and April, 2021. Retrospective analysis was performed on those patients with binocular and monocular CK measured by IOLMaster and Pentacam. Results. A total of 102 patients (204 eyes) were included, 64 of whom were female (62.75%). The flat (K1) and steep (K2) CK of anterior corneal surface (ACS) and flat (TK1) and steep (TK2) of total cornea measured with IOLMaster 700 were 44.16 ± 1.60 D, 45.09 ± 1.68 D, 44.12 ± 1.62 D, and 45.14 ± 1.69 D, respectively. Those measured with Pentacam were 44.31 ± 1.57 D, 45.22 ± 1.65 D, 44.15 ± 1.67 D, and 45.19 ± 1.82 D, respectively. The astigmatism of ACS and TCA were −0.94 ± 0.63 D and −1.02 ± 0.69 D (p < 0.01) in the IOLMaster group and −0.90 ± 0.59 D and −1.05 ± 0.81 D in the Pentacam group, respectively (p < 0.01). TCA measurement results of IOLMaster and Pentacam were consistent (Pearson = 0.710, p < 0.01), and there was no significant difference (p = 0.591). Conclusions. Total corneal astigmatism measured by IOLMaster was consistent with that measured by Pentacam. The difference between the astigmatism of anterior corneal surface and total cornea was detected in the measurement of IOLMaster and Pentacam, respectively.

17 February 2021 in Research Square
Verified
Preprint
Open access
PDF file
XLXiaochun Li
Xiaochun Li
JQJiayin Qin
Jiayin Qin
XCXiaoguang Cao
Xiaoguang Cao
ZRZeqin Ren
Zeqin Ren
TCTing Cui
Ting Cui
YBYongzhen Bao
Yongzhen Bao
BackgroundTo explore the correlation of visual field (VF) defect values and retinal nerve fiber layer (RNFL) thickness for the intracranial tumor and glaucoma patients. MethodsRetrospective analysis is performed for the intracranial and glaucoma patients, whose VF defect values measured with Octopus perimeter cluster analysis, and RNFL thickness and optic disk parameters measured with swept source OCT. The differences between VF and RNFL (included the data of optic disc) are calculated. The correlation between VF defect values and RNFL thickness are explored.Results43 eyes of 29 patients with the intracranial tumor and 39 eyes of 23 patients with the glaucoma are enrolled. Thickness of RNFL not only for the whole (360°), but also for the four quadrants are thinner in the glaucoma group than those of the intracranial tumor group (p<0.05). There is no significant difference of VF for those two groups. Stronger correlation for mean deviations (MD)s of VF ten clusters and RNFL thickness of OCT twelve sectors is found in the glaucoma patients, but few in the intracranial tumor patients. Logistic regression also shows the RNFL loss tending to the diagnosis of glaucoma, and the VF damage is inclined to the diagnosis of intracranial tumor.ConclusionsIntracranial tumor has a weak correlation between the RNFL thickness and Octopus VF MD, compared with that of glaucoma. OCT and Octopus VF might provide more helpful information for the antidiastole of intracranial tumor and glaucoma.