Richte C.L. Schuurmann

Dr. Richte C.L. Schuurmann

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in JMIR Formative Research
Verified
Journal Article
Open access
MHMarjolein Haveman
Marjolein Haveman
MRMathilde C van Rossum
Mathilde C van Rossum
RVRoswita M E Vaseur
Roswita M E Vaseur
CRClaire van der Riet
Claire van der Riet
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
MTMonique Tabak
Monique Tabak
Background: Continuous telemonitoring of vital signs in a clinical or home setting may lead to improved knowledge of patients’ baseline vital signs and earlier detection of patient deterioration, and it may also facilitate the migration of care toward home. Little is known about the performance of available wearable sensors, especially during daily life activities, although accurate technology is critical for clinical decision-making. Objective: The aim of this study is to assess the data availability, accuracy, and concurrent validity of vital sign data measured with wearable sensors in volunteers during various daily life activities in a simulated free-living environment. Methods: Volunteers were equipped with 4 wearable sensors (Everion placed on the left and right arms, VitalPatch, and Fitbit Charge 3) and 2 reference devices (Oxycon Mobile and iButton) to obtain continuous measurements of heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2), and temperature. Participants performed standardized activities, including resting, walking, metronome breathing, chores, stationary cycling, and recovery afterward. Data availability was measured as the percentage of missing data. Accuracy was evaluated by the median absolute percentage error (MAPE) and concurrent validity using the Bland-Altman plot with mean difference and 95% limits of agreement (LoA). Results: A total of 20 volunteers (median age 64 years, range 20-74 years) were included. Data availability was high for all vital signs measured by VitalPatch and for HR and temperature measured by Everion. Data availability for HR was the lowest for Fitbit (4807/13,680, 35.14% missing data points). For SpO2 measured by Everion, median percentages of missing data of up to 100% were noted. The overall accuracy of HR was high for all wearable sensors, except during walking. For RR, an overall MAPE of 8.6% was noted for VitalPatch and that of 18.9% for Everion, with a higher MAPE noted during physical activity (up to 27.1%) for both sensors. The accuracy of temperature was high for VitalPatch (MAPE up to 1.7%), and it decreased for Everion (MAPE from 6.3% to 9%). Bland-Altman analyses showed small mean differences of VitalPatch for HR (0.1 beats/min [bpm]), RR (−0.1 breaths/min), and temperature (0.5 °C). Everion and Fitbit underestimated HR up to 5.3 (LoA of −39.0 to 28.3) bpm and 11.4 (LoA of −53.8 to 30.9) bpm, respectively. Everion had a small mean difference with large LoA (−10.8 to 10.4 breaths/min) for RR, underestimated SpO2 (>1%), and overestimated temperature up to 2.9 °C. Conclusions: Data availability, accuracy, and concurrent validity of the studied wearable sensors varied and differed according to activity. In this study, the accuracy of all sensors decreased with physical activity. Of the tested sensors, VitalPatch was found to be the most accurate and valid for vital signs monitoring.

28 March 2017 in Journal of Endovascular Therapy
Verified
Journal Article
Open access
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
KNKim van Noort
Kim van Noort
SOSimon P. Overeem
Simon P. Overeem
KOKenneth Ouriel
Kenneth Ouriel
WJWilliam D. Jordan
William D. Jordan
JVJean-Paul P. M. de Vries
Jean-Paul P. M. de Vries
Purpose: To evaluate the association between aortic curvature and other preoperative anatomical characteristics and late (>1 year) type Ia endoleak and endograft migration in endovascular aneurysm repair (EVAR) patients. Methods: Eight high-volume EVAR centers contributed 116 EVAR patients (mean age 81±7 years; 103 men) to the study: 36 patients (mean age 82±7 years; 31 men) with endograft migration and/or type Ia endoleak diagnosed >1 year after the initial EVAR and 80 controls without early or late complications. Aortic curvature was calculated from the preoperative computed tomography scan as the maximum and average curvature over 5 predefined aortic segments: the entire infrarenal aortic neck, aneurysm sac, and the suprarenal, juxtarenal, and infrarenal aorta. Other morphological characteristics included neck length, neck diameter, mural neck calcification and thrombus, suprarenal and infrarenal angulation, and largest aneurysm sac diameter. Independent risk factors were identified using backward stepwise logistic regression. Relevant cutoff values for each of the variables in the final regression model were determined with the receiver operator characteristic curve. Results: Logistic regression identified maximum curvature over the length of the aneurysm sac (>47 m−1; p=0.023), largest aneurysm sac diameter (>56 mm; p=0.028), and mural neck thrombus (>11° circumference; p<0.001) as independent predictors of late migration and type Ia endoleak. Conclusion: Aortic curvature is a predictor for late type Ia endoleak and endograft migration after EVAR. These findings suggest that aortic curvature is a better parameter than angulation to predict post-EVAR failure and should be included as a hostile neck parameter.

26 March 2018 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
KNKim van Noort
Kim van Noort
SOSimon P. Overeem
Simon P. Overeem
RVRuben van Veen
Ruben van Veen
KOKenneth Ouriel
Kenneth Ouriel
JVJean-Paul P. M. de Vries
Jean-Paul P. M. de Vries
Purpose: To describe the added value of determining changes in position and apposition on computed tomography angiography (CTA) after endovascular aneurysm repair (EVAR) to detect early caudal displacement of the device and to prevent type Ia endoleak. Methods: Four groups of elective EVAR patients were selected from a dataset purposely enriched with type Ia endoleak and migration (>10 mm) cases. The groups included cases of late type Ia endoleak (n=36), migration (n=9), a type II endoleak (n=16), and controls without post-EVAR complications (n=37). Apposition of the endograft fabric with the aortic neck, shortest distance between the fabric and the renal arteries, expansion of the main body (or dilatation of the aorta in the infrarenal sealing zone), and tilt of the endograft toward the aortic axis were determined on the first postoperative and the last available CTA scan without type Ia endoleak or migration. Differences in these endograft dimensions were compared between the first vs last scan and among the 4 groups. Results: No significant differences in endograft configurations were observed among the groups on the first postoperative CTA scan. On the last CTA scan before a complication arose, the position of the fabric relative to the renal arteries, expansion of the main body, and apposition of the fabric with the aortic neck were significantly different between the type Ia endoleak (median follow-up 15 months) and migration groups (median follow-up 23 months) compared with the control group (median follow-up 19 months). Most endograft dimensions had changed significantly compared with the first postoperative CTA scan for all groups. Apposition had increased in the control group but had decreased significantly in the type Ia endoleak and migration groups. Conclusion: Progressive changes in dimensions of the endograft within the infrarenal neck could be detected on regular CTA scans before the complication became urgent in many patients.

1 March 2016 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
KOKenneth Ouriel
Kenneth Ouriel
BMBart E. Muhs
Bart E. Muhs
WJWilliam D. Jordan
William D. Jordan
RORichard L. Ouriel
Richard L. Ouriel
JVJean-Paul P.M. de Vries
Jean-Paul P.M. de Vries

1 August 2017 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
SOSimon P. Overeem
Simon P. Overeem
JBJohannes T. Boersen
Johannes T. Boersen
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
EJErik Groot Jebbink
Erik Groot Jebbink
CSCornelis H. Slump
Cornelis H. Slump
JVJean-Paul P.M. de Vries
Jean-Paul P.M. de Vries

18 March 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
WVWillemina Adrianne van Veldhuizen
Willemina Adrianne van Veldhuizen
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
FIFrank IJpma
Frank IJpma
RKRogier H. J. Kropman
Rogier H. J. Kropman
GAGeorge A. Antoniou
George A. Antoniou
Jean-Paul P.M. De VriesJean-Paul P.M. De Vries
Jean-Paul P.M. De Vries
Hostile aortic neck characteristics, such as short length and large diameter, have been associated with type Ia endoleaks and reintervention after endovascular aneurysm repair (EVAR). However, such characteristics partially describe the complex aortic neck morphology. A more comprehensive quantitative description of 3D neck shape might lead to new insights into the relationship between aortic neck morphology and EVAR outcomes in individual patients. This study identifies the 3D morphological shape components that describe the infrarenal aortic neck through a statistical shape model (SSM). Pre-EVAR CT scans of 97 patients were used to develop the SSM. Parameterization of the morphology was based on the center lumen line reconstruction, a triangular surface mesh of the aortic lumen, 3D coordinates of the renal arteries, and the distal end of the aortic neck. A principal component analysis of the parametrization of the aortic neck coordinates was used as input for the SSM. The SSM consisted of 96 principal components (PCs) that each described a unique shape feature. The first five PCs represented 95% of the total morphological variation in the dataset. The SSM is an objective model that provides a quantitative description of the neck morphology of an individual patient.