Shengchun Liu

Prof. Shengchun Liu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
YHYing Hao
Ying Hao
HQHaifeng Qi
Haifeng Qi
SLShengchun Liu
Shengchun Liu
VNVictor Nian
Victor Nian
ZZZhongyao Zhang
Zhongyao Zhang
The developments in urban rail transit (URT) construction are associated with the benefits of moving people efficiently and the negative impacts of noise and vibrations caused to surroundings. Despite a proliferation of studies conducted throughout the world, very few studies employed the field measurement approach due to various limitations. Using a metropolitan city, Tianjin (China), as an example, field measurement was set up to monitor the indoor vibration and noise spectrum in buildings near urban rapid transit lines to establish a baseline as well as the effectiveness of corresponding mitigation measures, namely wheel-rail polishing and train speed reduction. While our study suggests a maximum 6 dB reduction in indoor vibration, the effectiveness of noise and vibration reduction measures depends on the attenuation of the main frequency corresponding to the secondary radiation noise of the indoor vibration excitation in the building. In our field test, the peaks of the frequency spectrum were found to be 40, 50, 63 and 80 Hz. The secondary radiation noise attenuation and vibration were invariant to the change in frequency spectrum. Mitigation measures such as polishing may cause vibration frequency to peak in non-main frequency spectrums. URT speed reduction will lead to vibration and noise attenuation energy being concentrated at around 50 Hz. Given the presently inconsistent and widely varying industrial and international standards, this study can provide important field measurement data supporting future development in standards, regulation and legislation with respect to URT development, especially in mature townships.

22 November 2024 in Applied Thermal Engineering
Verified
Journal Article
Closed access
SLShengchun Liu
Shengchun Liu
SGShentong Guo
Shentong Guo
HSHaiwang Sun
Haiwang Sun
ZXZhiming Xu
Zhiming Xu
XLXueqiang Li
Xueqiang Li
XWXinyue Wang
Xinyue Wang

8 May 2018 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
MSMengjie Song
Mengjie Song
LLLiao Liyuan
Liao Liyuan
NFNiu Fuxin
Niu Fuxin
Ning MaoNing Mao
Ning Mao
SLShengchun Liu
Shengchun Liu
HYHu Yanxin
Hu Yanxin
Phase change materials (PCMs) are widely applied in recent decades due to their good thermal performance in energy systems. Their applications are mainly limited by the phase change temperature and latent heat. Many publications are reported around the characteristic improvement of binary organic PCMs. The thermal stability study on organic binary PCMs used in thermal energy storage applications becomes fundamental and meaningful. In this study, thermal stability of three types of organic binary PCMs was experimentally investigated, which are frequently used in building and industry applications. To qualitatively investigate the stability of composite PCMs, differential scanning calorimetry (DSC), and Fourier-transform infrared spectroscopy (FT-IR) spectra testing of samples were also conducted. Experimental results showed that the selected composite PCMs, capric acid (CA), and myristic acid (MA), had the best thermal performances, with its phase change temperature unchanged and heat of fusion decreased only 8.88 J/g, or 4.55%, after 2000 thermal cycles. Furthermore, quality ratio of required PCMs as the variation of operation duration was analyzed to quantitatively prepare the materials. The PCMs can successfully operate about 3125 times when prepared as 1.20 times of its calculated value by starting fusion heat. Conclusions of this research work can also be used for guiding the selection and preparation of other energy storage materials.

28 March 2025 in Energy Conversion and Management
Verified
Journal Article
Closed access
BDBaomin Dai
Baomin Dai
PYPeifang Yang
Peifang Yang
SLShengchun Liu
Shengchun Liu
RZRuirui Zhao
Ruirui Zhao
XLXuan Li
Xuan Li
XWXiangjun Wang
Xiangjun Wang

3 April 2017 in HKIE Transactions
Verified
Journal Article
Closed access
ZSZhili Sun
Zhili Sun
SLShengchun Liu
Shengchun Liu
YLYoucai Liang
Youcai Liang
MSMengjie Song
Mengjie Song
JGJiangfeng Guo
Jiangfeng Guo
An experimental study was conducted on the optimal charge of carbon dioxide in water–water heat pump systems (WWHPSs) with and without an internal heat exchanger (IHX). An appropriate carbon dioxide charge standard was obtained from the experimental results. All tests were conducted with the inlet and outlet water temperatures set to 12°C and 7°C in the evaporator, respectively and 20°C and 55°C in the gas cooler, respectively. During the tests, the evaporation temperature was 0°C. The coefficient of performance of cooling (COPc) and coefficient of performance of heating (COPh) increased by 8.3% and 0.7% in the WWHPS with an IHX compared with the WWHPS without an IHX. Under the test conditions, the optimal carbon dioxide charges with and without an IHX were found to be 2.0 kg and 2.25 kg, respectively. The test results show that the optimal carbon dioxide charge decreases by 11.1% when an IHX is included in the WWHPS.

17 February 2017 in Frontiers in Energy
Verified
Journal Article
Closed access
PDF file
SLShengchun Liu
Shengchun Liu
MSMing Song
Ming Song
LHLing Hao
Ling Hao
PWPengxiao Wang
Pengxiao Wang