Simon Stankoski

Mr. Simon Stankoski


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Martin GjoreskiMartin Gjoreski
Martin Gjoreski
IKIvana Kiprijanovska
Ivana Kiprijanovska
SSSimon Stankoski
Simon Stankoski
IMIfigeneia Mavridou
Ifigeneia Mavridou
MBM. John Broulidakis
M. John Broulidakis
CNCharles Nduka
Charles Nduka
Using a novel wearable surface electromyography (sEMG), we investigated induced affective states by measuring the activation of facial muscles traditionally associated withpositive(left/right orbicularis and left/right zygomaticus) andnegativeexpressions (the corrugator muscle). In a sample of 38 participants that watched 25 affective videos in a virtual reality environment, we found that each of the three variables examined—subjective valence, subjective arousal, and objective valence measured via the validated video types (positive, neutral, and negative)—sEMG amplitude varied significantly depending on video content. sEMG aptitude from “positive muscles” increased when participants were exposed topositively valenced stimulicompared withstimuli that was negatively valenced. In contrast, activation of “negative muscles” was elevated following exposure tonegatively valenced stimulicompared with positively valenced stimuli. High arousal videos increased muscle activations compared to low arousal videos in all the measured muscles except the corrugator muscle. In line with previous research, the relationship betweensEMG amplitudeas a function of subjective valence was V-shaped.

8 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SSSimon Stankoski
Simon Stankoski
IKIvana Kiprijanovska
Ivana Kiprijanovska
IMIfigeneia Mavridou
Ifigeneia Mavridou
CNCharles Nduka
Charles Nduka
Hristijan GjoreskiHristijan Gjoreski
Hristijan Gjoreski
Martin GjoreskiMartin Gjoreski
Martin Gjoreski
Breathing rate is considered one of the fundamental vital signs and a highly informative indicator of physiological state. Given that the monitoring of heart activity is less complex than the monitoring of breathing, a variety of algorithms have been developed to estimate breathing activity from heart activity. However, estimating breathing rate from heart activity outside of laboratory conditions is still a challenge. The challenge is even greater when new wearable devices with novel sensor placements are being used. In this paper, we present a novel algorithm for breathing rate estimation from photoplethysmography (PPG) data acquired from a head-worn virtual reality mask equipped with a PPG sensor placed on the forehead of a subject. The algorithm is based on advanced signal processing and machine learning techniques and includes a novel quality assessment and motion artifacts removal procedure. The proposed algorithm is evaluated and compared to existing approaches from the related work using two separate datasets that contains data from a total of 37 subjects overall. Numerous experiments show that the proposed algorithm outperforms the compared algorithms, achieving a mean absolute error of 1.38 breaths per minute and a Pearson’s correlation coefficient of 0.86. These results indicate that reliable estimation of breathing rate is possible based on PPG data acquired from a head-worn device.

26 September 2024 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
SSSimon Stankoski
Simon Stankoski
IKIvana Kiprijanovska
Ivana Kiprijanovska
Martin GjoreskiMartin Gjoreski
Martin Gjoreski
FPFilip Panchevski
Filip Panchevski
BSBorjan Sazdov
Borjan Sazdov
Hristijan GjoreskiHristijan Gjoreski
Hristijan Gjoreski
Background: The increasing prevalence of obesity necessitates innovative approaches to better understand this health crisis, particularly given its strong connection to chronic diseases such as diabetes, cancer, and cardiovascular conditions. Monitoring dietary behavior is crucial for designing effective interventions that help decrease obesity prevalence and promote healthy lifestyles. However, traditional dietary tracking methods are limited by participant burden and recall bias. Exploring microlevel eating activities, such as meal duration and chewing frequency, in addition to eating episodes, is crucial due to their substantial relation to obesity and disease risk. Objective: The primary objective of the study was to develop an accurate and noninvasive system for automatically monitoring eating and chewing activities using sensor-equipped smart glasses. The system distinguishes chewing from other facial activities, such as speaking and teeth clenching. The secondary objective was to evaluate the system’s performance on unseen test users using a combination of laboratory-controlled and real-life user studies. Unlike state-of-the-art studies that focus on detecting full eating episodes, our approach provides a more granular analysis by specifically detecting chewing segments within each eating episode. Methods: The study uses OCO optical sensors embedded in smart glasses to monitor facial muscle activations related to eating and chewing activities. The sensors measure relative movements on the skin’s surface in 2 dimensions (X and Y). Data from these sensors are analyzed using deep learning (DL) to distinguish chewing from other facial activities. To address the temporal dependence between chewing events in real life, we integrate a hidden Markov model as an additional component that analyzes the output from the DL model. Results: Statistical tests of mean sensor activations revealed statistically significant differences across all 6 comparison pairs (P<.001) involving 2 sensors (cheeks and temple) and 3 facial activities (eating, clenching, and speaking). These results demonstrate the sensitivity of the sensor data. Furthermore, the convolutional long short-term memory model, which is a combination of convolutional and long short-term memory neural networks, emerged as the best-performing DL model for chewing detection. In controlled laboratory settings, the model achieved an F1-score of 0.91, demonstrating robust performance. In real-life scenarios, the system demonstrated high precision (0.95) and recall (0.82) for detecting eating segments. The chewing rates and the number of chews evaluated in the real-life study showed consistency with expected real-life eating behaviors. Conclusions: The study represents a substantial advancement in dietary monitoring and health technology. By providing a reliable and noninvasive method for tracking eating behavior, it has the potential to revolutionize how dietary data are collected and used. This could lead to more effective health interventions and a better understanding of the factors influencing eating habits and their health implications.

19 April 2023
Verified
Conference Paper
Open access
Hristijan GjoreskiHristijan Gjoreski
Hristijan Gjoreski
IMIfigeneia Mavridou
Ifigeneia Mavridou
JAJames Archer William Archer
James Archer William Archer
ACAndrew Cleal
Andrew Cleal
SSSimon Stankoski
Simon Stankoski
CNCharles Nduka
Charles Nduka
The paper presents the OCOsenseTM smart glasses system, which recognizes and monitors facial gestures and expressions by using non-contact optomyographic OCOTM sensors and an IMU placed inside the frames of the glasses. The glasses stream the sensor data via Bluetooth to a mobile device, where data-fusion algorithms are applied, to recognize facial gestures and expressions in real time. The recognized gestures and expressions are then used as input to interact with the mobile device. We will demonstrate how the system is used in practice, i.e., a participant will wear the OCOsenseTM glasses and will interact with the mobile device by doing facial gestures and expressions. Three use cases will be presented: video control, call control, and game control. We believe that the OCOsenseTM glasses are the next generation in wearables, which will allow for a better understanding of the user's context and emotional state, and will allow numerous ways to interact with smart devices and computer systems, even within Augmented and Extended Reality environments. Future versions of the system can be used in a variety of domains, including, affective computing, remote mental-health monitoring, and hands-free human-computer interaction, thus improving accessibility and inclusivity of future technologies.

14 March 2025 in IEEE Access
Verified
Journal Article
Open access
MMMatea Marinova
Matea Marinova
ECEmilija Chona
Emilija Chona
AKAndrej Kotevski
Andrej Kotevski
BSBorjan Sazdov
Borjan Sazdov
IKIvana Kiprijanovska
Ivana Kiprijanovska
HGHristijan Gjoreski
Hristijan Gjoreski
Facial Expression Recognition (FER) and Human Activity Recognition (HAR) are key areas in wearable computing, with applications in healthcare, fitness, and human-computer interaction. This study explores the use of Emteq’s OCOsenseTM smart glasses for FER and HAR, which incorporate optomyographic sensors and a 9-axis inertial measurement unit (IMU). Using deep learning (DL) models, including CNNs, ConvLSTM, and STResNet variants, the study compares the performance of FER for six expression classes and HAR for seven different activities. We investigate the impact of the ConvBoost framework on model performance, extending its use beyond HAR with IMU data and introducing end-to-end learning for FER using OCOsenseTM smart glasses. Our findings confirm that ConvBoost effectively improves performance of complex overfitting-prone models. Furthermore, the results also reveal that using ConvBoost in simpler models, such as the 1-dimensional convolutional neural network (CNN 1D), leads to a decrease in F1-score. The best performing models, Attention ConvLSTM for FER and ConvLSTM for HAR (in combination with ConvBoost), achieved a macro F1-score of 0.78 and 0.88, respectively. These results highlight the potential of smart glasses for FER and HAR, establishing benchmark results for future advancements in glasses-based wearable computing.

8 October 2023
Verified
Conference Paper
Open access
BSBorjan Sazdov
Borjan Sazdov
BJBojan Jakimovski
Bojan Jakimovski
SSSimon Stankoski
Simon Stankoski
IKIvana Kiprijanovska
Ivana Kiprijanovska
BSBojan Sofronievski
Bojan Sofronievski
Hristijan GjoreskiHristijan Gjoreski
Hristijan Gjoreski
Human Activity Recognition (HAR) holds valuable potential as a digital biomarker, offering insights into individuals' physical activities and well-being. Leveraging wearable devices to monitor human activities can serve as an integral component of digital therapeutics, offering valuable insights into an individual's health and behavior. However, privacy concerns in HAR systems pose a significant challenge as users' data can be at risk of exposure and necessitates robust protection measures. To mitigate these concerns, the adoption of privacy-preserving techniques, such as federated learning, becomes necessary. This paper addresses the topic of Privacy-aware Human Activity Recognition (HAR) with Smart Glasses and explores a federated learning approach to achieve accurate recognition while preserving data privacy. The study highlights the trade-off between model complexity, recognition performance, and data privacy. Initially, a comparison was conducted between a complex deep learning network (STResNet) and a simpler deep learning network (DANA). The complex network exhibited an F1-Macro score of 0.87, while the simpler network achieved 0.82. Subsequently, the simpler network was further evaluated by comparing it to its federated learning implementation. The results revealed that the simpler network attained an F1-Macro score of 0.85, whereas federated learning achieved a slightly lower score of 0.80. These findings shed light on the performance disparities between the different approaches.