Laura Quinn

Ms. Laura Quinn

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in The Lancet Gastroenterology & Hepatology
Verified
Journal Article
Open access
STStuart A. Taylor
Stuart A. Taylor
SMSusan Mallett
Susan Mallett
GBGauraang Bhatnagar
Gauraang Bhatnagar
RBRachel Baldwin-Cleland
Rachel Baldwin-Cleland
SBStuart Bloom
Stuart Bloom
SMSteve Morris
Steve Morris
Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. We recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed. 284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72-86]) and presence (97% [91-99]) were significantly greater than that of ultrasound (70% [62-78] for disease extent, 92% [84-96] for disease presence); a 10% (95% CI 1-18; p=0·027) difference for extent, and 5% (1-9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85-98]) was significantly greater than that of ultrasound (81% [64-91]); a difference of 14% (1-27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86-99) with MRE and 84% (65-94) with ultrasound (difference 12% [0-25]; p=0·054). There were no serious adverse events. Both MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly. National Institute of Health and Research Health Technology Assessment.

1 August 2023 in British Journal of Radiology
Verified
Journal Article
Open access
LQLaura Quinn
Laura Quinn
KTKonstantinos Tryposkiadis
Konstantinos Tryposkiadis
JDJon Deeks
Jon Deeks
HVHenrica C.W. De Vet
Henrica C.W. De Vet
SMSue Mallett
Sue Mallett
ASAlice Sitch
Alice Sitch
Objectives: To review the methodology of interobserver variability studies; including current practice and quality of conducting and reporting studies. Methods: Interobserver variability studies between January 2019 and January 2020 were included; extracted data comprised of study characteristics, populations, variability measures, key results, and conclusions. Risk of bias was assessed using the COSMIN tool for assessing reliability and measurement error. Results: Seventy-nine full-text studies were included covering various imaging tests and clinical areas. The median number of patients was 47 (IQR:23–88), and observers were 4 (IQR:2–7), with sample size justified in 12 (15%) studies. Most studies used static images (n = 75, 95%), where all observers interpreted images for all patients (n = 67, 85%). Intraclass correlation coefficients (ICC) (n = 41, 52%), Kappa (κ) statistics (n = 31, 39%) and percentage agreement (n = 15, 19%) were most commonly used. Interpretation of variability estimates often did not correspond with study conclusions. The COSMIN risk of bias tool gave a very good/adequate rating for 52 studies (66%) including any studies that used variability measures listed in the tool. For studies using static images, some study design standards were not applicable and did not contribute to the overall rating. Conclusions: Interobserver variability studies have diverse study designs and methods, the impact of which requires further evaluation. Sample size for patients and observers was often small without justification. Most studies report ICC and κ values, which did not always coincide with the study conclusion. High ratings were assigned to many studies using the COSMIN risk of bias tool, with certain standards scored ‘not applicable’ when static images were used. Advances in knowledge: The sample size for both patients and observers was often small without justification. For most studies, observers interpreted static images and did not evaluate the process of acquiring the imaging test, meaning it was not possible to assess many COSMIN risk of bias standards for studies with this design. Most studies reported intraclass correlation coefficient and κ statistics; study conclusions often did not correspond with results.

1 July 2019 in The Lancet Gastroenterology & Hepatology
Verified
Journal Article
Open access
STStuart A. Taylor
Stuart A. Taylor
SMSue Mallett
Sue Mallett
SBSandy Beare
Sandy Beare
GBGauraang Bhatnagar
Gauraang Bhatnagar
DBDominic Blunt
Dominic Blunt
SLSara Lock
Sara Lock
Whole-body MRI (WB-MRI) could be an alternative to multimodality staging of colorectal cancer, but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in colorectal cancer. The Streamline C trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed colorectal cancer. Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or polyp cancer. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs), and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN43958015, and is complete. Between March 26, 2013, and Aug 19, 2016, 1020 patients were screened for eligibility. 370 patients were recruited, 299 of whom completed the trial; 68 (23%) had metastasis at baseline. Pathway sensitivity was 67% (95% CI 56 to 78) for WB-MRI and 63% (51 to 74) for standard pathways, a difference in sensitivity of 4% (-5 to 13, p=0·51). No adverse events related to imaging were reported. Specificity did not differ between WB-MRI (95% [95% CI 92-97]) and standard pathways (93% [90-96], p=0·48). Agreement with the multidisciplinary team's final treatment decision was 96% for WB-MRI and 95% for the standard pathway. Time to complete staging was shorter for WB-MRI (median, 8 days [IQR 6-9]) than for the standard pathway (13 days [11-15]); a 5-day (3-7) difference. WB-MRI required fewer tests (median, one [95% CI 1 to 1]) than did standard pathways (two [2 to 2]), a difference of one (1 to 1). Mean per-patient staging costs were £216 (95% CI 211-221) for WB-MRI and £285 (260-310) for standard pathways. WB-MRI staging pathways have similar accuracy to standard pathways and reduce the number of tests needed, staging time, and cost. UK National Institute for Health Research.

1 June 2019 in The Lancet Respiratory Medicine
Verified
Journal Article
Open access
STStuart A. Taylor
Stuart A. Taylor
SMSue Mallett
Sue Mallett
SBSimon Ball
Simon Ball
SBSandy Beare
Sandy Beare
GBGauraang Bhatnagar
Gauraang Bhatnagar
SHSarah Howling
Sarah Howling
Whole-body magnetic resonance imaging (WB-MRI) could be an alternative to multi-modality staging of non-small-cell lung cancer (NSCLC), but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in NSCLC. The Streamline L trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed NSCLC that was potentially radically treatable on diagnostic chest CT (defined as stage IIIb or less). Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or histologies other than NSCLC. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs) and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN50436483, and is complete. Between Feb 26, 2013, and Sept 5, 2016, 976 patients were screened for eligibility. 353 patients were recruited, 187 of whom completed the trial; 52 (28%) had metastasis at baseline. Pathway sensitivity was 50% (95% CI 37-63) for WB-MRI and 54% (41-67) for standard pathways, a difference of 4% (-7 to 15, p=0·73). No adverse events related to imaging were reported. Specificity did not differ between WB-MRI (93% [88-96]) and standard pathways (95% [91-98], p=0·45). Agreement with the multidisciplinary team's final treatment decision was 98% for WB-MRI and 99% for the standard pathway. Time to complete staging was shorter for WB-MRI (13 days [12-14]) than for the standard pathway (19 days [17-21]); a 6-day (4-8) difference. The number of tests required was similar WB-MRI (one [1-1]) and standard pathways (one [1-2]). Mean per-patient costs were £317 (273-361) for WBI-MRI and £620 (574-666) for standard pathways. WB-MRI staging pathways have similar accuracy to standard pathways, and reduce the staging time and costs. UK National Institute for Health Research.

1 December 2019 in Health Technology Assessment
Verified
Journal Article
Open access
STStuart A. Taylor
Stuart A. Taylor
SMSusan Mallett
Susan Mallett
AMAnne Miles
Anne Miles
SMStephen Morris
Stephen Morris
LQLaura Quinn
Laura Quinn
SHSteve Halligan
Steve Halligan
Background: Whole-body magnetic resonance imaging is advocated as an alternative to standard pathways for staging cancer. Objectives: The objectives were to compare diagnostic accuracy, efficiency, patient acceptability, observer variability and cost-effectiveness of whole-body magnetic resonance imaging and standard pathways in staging newly diagnosed non-small-cell lung cancer (Streamline L) and colorectal cancer (Streamline C). Design: The design was a prospective multicentre cohort study. Setting: The setting was 16 NHS hospitals. Participants: Consecutive patients aged ≥ 18 years with histologically proven or suspected colorectal (Streamline C) or non-small-cell lung cancer (Streamline L). Interventions: Whole-body magnetic resonance imaging. Standard staging investigations (e.g. computed tomography and positron emission tomography–computed tomography). Reference standard: Consensus panel decision using 12-month follow-up data. Main outcome measures: The primary outcome was per-patient sensitivity difference between whole-body magnetic resonance imaging and standard staging pathways for metastasis. Secondary outcomes included differences in specificity, the nature of the first major treatment decision, time and number of tests to complete staging, patient experience and cost-effectiveness. Results: Streamline C – 299 participants were included. Per-patient sensitivity for metastatic disease was 67% (95% confidence interval 56% to 78%) and 63% (95% confidence interval 51% to 74%) for whole-body magnetic resonance imaging and standard pathways, respectively, a difference in sensitivity of 4% (95% confidence interval –5% to 13%; p = 0.51). Specificity was 95% (95% confidence interval 92% to 97%) and 93% (95% confidence interval 90% to 96%) respectively, a difference of 2% (95% confidence interval –2% to 6%). Pathway treatment decisions agreed with the multidisciplinary team treatment decision in 96% and 95% of cases, respectively, a difference of 1% (95% confidence interval –2% to 4%). Time for staging was 8 days (95% confidence interval 6 to 9 days) and 13 days (95% confidence interval 11 to 15 days) for whole-body magnetic resonance imaging and standard pathways, respectively, a difference of 5 days (95% confidence interval 3 to 7 days). The whole-body magnetic resonance imaging pathway was cheaper than the standard staging pathway: £216 (95% confidence interval £211 to £221) versus £285 (95% confidence interval £260 to £310). Streamline L – 187 participants were included. Per-patient sensitivity for metastatic disease was 50% (95% confidence interval 37% to 63%) and 54% (95% confidence interval 41% to 67%) for whole-body magnetic resonance imaging and standard pathways, respectively, a difference in sensitivity of 4% (95% confidence interval –7% to 15%; p = 0.73). Specificity was 93% (95% confidence interval 88% to 96%) and 95% (95% confidence interval 91% to 98%), respectively, a difference of 2% (95% confidence interval –2% to 7%). Pathway treatment decisions agreed with the multidisciplinary team treatment decision in 98% and 99% of cases, respectively, a difference of 1% (95% confidence interval –2% to 4%). Time for staging was 13 days (95% confidence interval 12 to 14 days) and 19 days (95% confidence interval 17 to 21 days) for whole-body magnetic resonance imaging and standard pathways, respectively, a difference of 6 days (95% confidence interval 4 to 8 days). The whole-body magnetic resonance imaging pathway was cheaper than the standard staging pathway: £317 (95% confidence interval £273 to £361) versus £620 (95% confidence interval £574 to £666). Participants generally found whole-body magnetic resonance imaging more burdensome than standard imaging but most participants preferred the whole-body magnetic resonance imaging staging pathway if it reduced time to staging and/or number of tests. Limitations: Whole-body magnetic resonance imaging was interpreted by practitioners blinded to other clinical data, which may not fully reflect how it is used in clinical practice. Conclusions: In colorectal and non-small-cell lung cancer, the whole-body magnetic resonance imaging staging pathway has similar accuracy to standard staging pathways, is generally preferred by patients, improves staging efficiency and has lower staging costs. Future work should address the utility of whole-body magnetic resonance imaging for treatment response assessment. Trial registration: Current Controlled Trials ISRCTN43958015 and ISRCTN50436483. Funding: This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 23, No. 66. See the NIHR Journals Library website for further project information.

22 April 2022 in PLOS Global Public Health
Verified
Journal Article
Open access
PDF file
Mary OsuhMary Osuh
Mary Osuh
GOGbemisola A. Oke
Gbemisola A. Oke
RLRichard J. Lilford
Richard J. Lilford
EOEme Owoaje
Eme Owoaje
BHBronwyn Harris
Bronwyn Harris
YCYen-Fu Chen
Yen-Fu Chen
Oral diseases constitute a neglected epidemic in Low and Middle-Income Countries (LMICs). An understanding of its distribution and severity in different settings can aid the planning of preventive and therapeutic services. This study assessed the oral health conditions, risk factors, and treatment needs among adult residents in the slum and compared findings with non-slum urban residents in Ibadan, Nigeria. The Multistage sampling was used to select adult (≥18-years) residents from a slum and a non-slum urban sites. Information sought from participants included dietary habits, oral hygiene practices, and the use of dental services. Oral examinations were performed in line with WHO guidelines. Associations were examined using logistic regression. Mediation analysis was undertaken using generalized structural equation modeling. The sample comprised 678 slum and 679 non-slum residents. Median age in slum vs non-slum was 45 (IQR:32–50) versus 38 (IQR:29–50) years. Male: female ratio was 1:2 in both sites. Prevalence of oral diseases (slum vs non-slum sites): dental caries (27% vs 23%), gingival bleeding (75% vs 53%) and periodontal pocket (23% vs 16%). The odds of having dental caries were 21% higher for the slum dwellers compared to non-slum residents (OR = 1.21, 95% CI:0.94 to 1.56); and 50% higher for periodontal pocket (OR = 1.50, 95%CI: 1.13 to 1.98), after adjusting for age and sex. There was little evidence that tooth cleaning frequency mediated the relationship between place of residence and caries (OR = 0.95, 95%CI: 0.87 to 1.03 [indirect effect], 38% mediated) or periodontal pocket (OR = 0.95, 95%CI: 0.86 to 1.04, 15% mediated). Thirty-five percent and 27% of residents in the slum and non-slum sites respectively required the “prompt and urgent” levels of treatment need. Oral diseases prevalence in both settings are high and the prevalence was generally higher in the slum with correspondingly higher levels of prompt and urgent treatment needs. Participants may benefit from targeted therapeutic and health promotion intervention services.