Claudia Cella

Dr. Claudia Cella

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2012 in The Lancet
Verified
Journal Article
Closed access
CMChristopher J L Murray
Christopher J L Murray
TVTheo Vos
Theo Vos
RLRafael Lozano
Rafael Lozano
MNMohsen Naghavi
Mohsen Naghavi
AFAbraham D Flaxman
Abraham D Flaxman
ALAlan D Lopez
Alan D Lopez

1 December 2012 in The Lancet
Verified
Journal Article
Closed access
TVTheo Vos
Theo Vos
AFAbraham D Flaxman
Abraham D Flaxman
MNMohsen Naghavi
Mohsen Naghavi
RLRafael Lozano
Rafael Lozano
CMCatherine Michaud
Catherine Michaud
CMChristopher Jl Murray
Christopher Jl Murray

11 September 2012 in Diabetes Care
Verified
Journal Article
Open access
PDF file
PRPiero Ruggenenti
Piero Ruggenenti
EPEsteban Porrini
Esteban Porrini
FGFlavio Gaspari
Flavio Gaspari
NMNicola Motterlini
Nicola Motterlini
ACAntonio Cannata
Antonio Cannata
FIfor the GFR Study Investigators
for the GFR Study Investigators
OBJECTIVE: To describe the prevalence and determinants of hyperfiltration (glomerular filtration rate [GFR] ≥120 mL/min/1.73 m2), GFR decline, and nephropathy onset or progression in type 2 diabetic patients with normo- or microalbuminuria. RESEARCH DESIGN AND METHODS: We longitudinally studied 600 hypertensive type 2 diabetic patients with albuminuria <200 μg/min and who were retrieved from two randomized trials testing the renal effect of trandolapril and delapril. Target blood pressure (BP) was <120/80 mmHg, and HbA1c was <7%. GFR, albuminuria, and glucose disposal rate (GDR) were centrally measured by iohexol plasma clearance, nephelometry in three consecutive overnight urine collections, and hyperinsulinemic euglycemic clamp, respectively. RESULTS: Over a median (range) follow-up of 4.0 (1.7–8.1) years, GFR declined by 3.37 (5.71–1.31) mL/min/1.73 m2 per year. GFR change was bimodal over time: a larger reduction at 6 months significantly predicted slower subsequent decline (coefficient: −0.0054; SE: 0.0009), particularly among hyperfiltering patients. A total of 90 subjects (15%) were hyperfiltering at inclusion, and 11 of 47 (23.4%) patients with persistent hyperfiltration progressed to micro- or macroalbuminuria versus 53 (10.6%) of the 502 who had their hyperfiltration ameliorated at 6 months or were nonhyperfiltering since inclusion (hazard ratio 2.16 [95% CI 1.13–4.14]). Amelioration of hyperfiltration was independent of baseline characteristics or ACE inhibition. It was significantly associated with improved BP and metabolic control, amelioration of GDR, and slower long-term GFR decline on follow-up. CONCLUSIONS: Despite intensified treatment, patients with type 2 diabetes have a fast GFR decline. Hyperfiltration affects a subgroup of patients and may contribute to renal function loss and nephropathy onset or progression. Whether amelioration of hyperfiltration is renoprotective is worth investigating.

1 December 2015 in Particle and Fibre Toxicology
Verified
Journal Article
Open access
PDF file
CRCamilla Recordati
Camilla Recordati
MMMarcella De Maglie
Marcella De Maglie
SBSilvia Bianchessi
Silvia Bianchessi
SASimona Argentiere
Simona Argentiere
CCClaudia Cella
Claudia Cella
ESEugenio Scanziani
Eugenio Scanziani
Silver nanoparticles (AgNPs) are an important class of nanomaterials used as antimicrobial agents for a wide range of medical and industrial applications. However toxicity of AgNPs and impact of their physicochemical characteristics in in vivo models still need to be comprehensively characterized. The aim of this study was to investigate the effect of size and coating on tissue distribution and toxicity of AgNPs after intravenous administration in mice, and compare the results with those obtained after silver acetate administration. Male CD-1(ICR) mice were intravenously injected with AgNPs of different sizes (10 nm, 40 nm, 100 nm), citrate-or polyvinylpyrrolidone-coated, at a single dose of 10 mg/kg bw. An equivalent dose of silver ions was administered as silver acetate. Mice were euthanized 24 h after the treatment, and silver quantification by ICP-MS and histopathology were performed on spleen, liver, lungs, kidneys, brain, and blood. For all particle sizes, regardless of their coating, the highest silver concentrations were found in the spleen and liver, followed by lung, kidney, and brain. Silver concentrations were significantly higher in the spleen, lung, kidney, brain, and blood of mice treated with 10 nm AgNPs than those treated with larger particles. Relevant toxic effects (midzonal hepatocellular necrosis, gall bladder hemorrhage) were found in mice treated with 10 nm AgNPs, while in mice treated with 40 nm and 100 nm AgNPs lesions were milder or negligible, respectively. In mice treated with silver acetate, silver concentrations were significantly lower in the spleen and lung, and higher in the kidney than in mice treated with 10 nm AgNPs, and a different target organ of toxicity was identified (kidney). Administration of the smallest (10 nm) nanoparticles resulted in enhanced silver tissue distribution and overt hepatobiliary toxicity compared to larger ones (40 and 100 nm), while coating had no relevant impact. Distinct patterns of tissue distribution and toxicity were observed after silver acetate administration. It is concluded that if AgNPs become systemically available, they behave differently from ionic silver, exerting distinct and size-dependent effects, strictly related to the nanoparticulate form.

1 July 2013 in Kidney International
Verified
Journal Article
Open access
PDF file
FGFlavio Gaspari
Flavio Gaspari
PRPiero Ruggenenti
Piero Ruggenenti
EPEsteban Porrini
Esteban Porrini
NMNicola Motterlini
Nicola Motterlini
ACAntonio Cannata
Antonio Cannata
Giuseppe RemuzziGiuseppe Remuzzi
Giuseppe Remuzzi
There are no adequate studies that have formally tested the performance of different estimating formulas in patients with type 2 diabetes both with and without overt nephropathy. Here we evaluated the agreement between baseline GFRs, GFR changes at month 6, and long-term GFR decline measured by iohexol plasma clearance or estimated by 15 creatinine-based formulas in 600 type 2 diabetics followed for a median of 4.0 years. Ninety patients were hyperfiltering. The number of those identified by estimation formulas ranged from 0 to 24:58 were not identified by any formula. Baseline GFR was significantly underestimated and a 6-month GFR reduction was missed in hyperfiltering patients. Long-term GFR decline was also underestimated by all formulas in the whole study group and in hyper-, normo-, and hypofiltering patients considered separately. Five formulas generated positive slopes in hyperfiltering patients. Baseline concordance correlation coefficients and total deviation indexes ranged from 32.1% to 92.6% and from 0.21 to 0.53, respectively. Concordance correlation coefficients between estimated and measured long-term GFR decline ranged from -0.21 to 0.35. The agreement between estimated and measured values was also poor within each subgroup considered separately. Thus, our study questions the use of any estimation formula to identify hyperfiltering patients and monitor renal disease progression and response to treatment in type 2 diabetics without overt nephropathy.

18 March 2022 in Polymers
Verified
Journal Article
Open access
PDF file
CCClaudia Cella
Claudia Cella
RSRita La Spina
Rita La Spina
DMDora Mehn
Dora Mehn
FFFrancesco Fumagalli
Francesco Fumagalli
GCGiacomo Ceccone
Giacomo Ceccone
DGDouglas Gilliland
Douglas Gilliland
Micro- and nanoplastic (pMP and pNP, respectively) release is an emerging issue since these particles constitute a ubiquitous and growing pollutant, which not only threatens the environment but may have potential consequences for human health. In particular, there is concern about the release of secondary pMP and pNP from the degradation of plastic consumer products. The phenomenon is well-documented in relation to plastic waste in the environment but, more recently, reports of pMP generated even during the normal use of plastic food contact materials, such as water bottles, tea bags, and containers, have been published. So far, a validated and harmonized strategy to tackle the issue is not available. In this study, we demonstrate that plastic breakdown to pMP and pNP can occur during the normal use of polyethylene (PE) rice cooking bags and ice-cube bags as well as of nylon teabags. A multi-instrumental approach based on Raman microscopy, X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and particular attention on the importance of sample preparation were applied to evaluate the chemical nature of the released material and their morphology. In addition, a simple method based on Fourier transform infrared (FT-IR) spectroscopy is proposed for pNP mass quantification, resulting in the release of 1.13 ± 0.07 mg of nylon 6 from each teabag. However, temperature was shown to have a strong impact on the morphology and aggregation status of the released materials, posing to scientists and legislators a challenging question: are they micro- or nanoplastics or something else altogether?