Enzo Santos

Mr. Enzo Santos

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
LRLuciana Abrantes Rodrigues
Luciana Abrantes Rodrigues
ESEnzo Santos
Enzo Santos
PSPatrícia Seixas Alves Santos
Patrícia Seixas Alves Santos
YIYuzo Igarashi
Yuzo Igarashi
LOLuana Karine Resende Oliveira
Luana Karine Resende Oliveira
Givago SouzaGivago Souza
Givago Souza
Falls represent a public health issue around the world and prevention is an important part of the politics of many countries. The standard method of evaluating balance is posturography using a force platform, which has high financial costs. Other instruments, such as portable devices and smartphones, have been evaluated as low-cost alternatives to the screening of balance control. Although smartphones and wearables have different sizes, shapes, and weights, they have been systematically validated for static balance control tasks. Different studies have applied different experimental configurations to validate the inertial measurements obtained by these devices. We aim to evaluate the concurrent validity of a smartphone and a portable device for the evaluation of static balance control in the same group of participants. Twenty-six healthy and young subjects comprised the sample. The validity for static balance control evaluation of built-in accelerometers inside portable smartphone and wearable devices was tested considering force platform recordings as a gold standard for comparisons. A linear correlation (r) between the quantitative variables obtained from the inertial sensors and the force platform was used as an indicator of the concurrent validity. Reliability of the measures was calculated using Intraclass correlation in a subsample (n = 14). Smartphones had 11 out of 12 variables with significant moderate to very high correlation (r > 0.5, p < 0.05) with force platform variables in open eyes, closed eyes, and unipedal conditions, while wearable devices had 8 out of 12 variables with moderate to very high correlation (r > 0.5, p < 0.05) with force platform variables under the same task conditions. Significant reliabilities were found in closed eye conditions for smartphones and wearables. The smartphone and wearable devices had concurrent validity for the static balance evaluation and the smartphone had better validity results than the wearables for the static balance evaluation.

12 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AMAnderson Antunes da Costa Moraes
Anderson Antunes da Costa Moraes
MDManuela Brito Duarte
Manuela Brito Duarte
EFEduardo Veloso Ferreira
Eduardo Veloso Ferreira
GAGizele Cristina da Silva Almeida
Gizele Cristina da Silva Almeida
ESEnzo Santos
Enzo Santos
BCBianca Callegari
Bianca Callegari
The evaluation of anticipatory postural adjustments (APAs) requires high-cost and complex handling systems, only available at research laboratories. New alternative methods are being developed in this field, on the other hand, to solve this issue and allow applicability in clinic, sport and hospital environments. The objective of this study was to validate an app for mobile devices to measure the APAs during gait initiation by comparing the signals obtained from cell phones using the Momentum app with measurements made by a kinematic system. The center-of-mass accelerations of a total of 20 healthy subjects were measured by the above app, which read the inertial sensors of the smartphones, and by kinematics, with a reflective marker positioned on their lumbar spine. The subjects took a step forward after hearing a command from an experimenter. The variables of the anticipatory phase, prior to the heel-off and the step phase, were measured. In the anticipatory phase, the linear correlation of all variables measured by the two measurement techniques was significant and indicated a high correlation between the devices (APAonset: r = 0.95, p < 0.0001; APAamp: r = 0.71, p = 0.003, and PEAKtime: r = 0.95, p < 0.0001). The linear correlation between the two measurement techniques for the step phase variables measured by ques was also significant (STEPinterval: r = 0.56, p = 0.008; STEPpeak1: r = 0.79, p < 0.0001; and STEPpeak2: r = 0.64, p < 0.0001). The Bland–Altman graphs indicated agreement between instruments with similar behavior as well as subjects within confidence limits and low dispersion. Thus, using the Momentum cell phone application is valid for the assessment of APAs during gait initiation compared to the gold standard instrument (kinematics), proving to be a useful, less complex, and less costly alternative for the assessment of healthy individuals.

3 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TSThâmela Thaís Santos dos Santos
Thâmela Thaís Santos dos Santos
AMAmélia Pasqual Marques
Amélia Pasqual Marques
Luis Carlos Pereira MonteiroLuis Carlos Pereira Monteiro
Luis Carlos Pereira Monteiro
ESEnzo Santos
Enzo Santos
GPGustavo Henrique Lima Pinto
Gustavo Henrique Lima Pinto
BCBianca Callegari
Bianca Callegari
The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants’ bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland–Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment.

11 December 2023 in Frontiers in Neurology
Verified
Journal Article
Open access
BCBruna Danielle Campelo Corrêa
Bruna Danielle Campelo Corrêa
ESEnzo Santos
Enzo Santos
ABAnderson Belgamo
Anderson Belgamo
GPGustavo Henrique Lima Pinto
Gustavo Henrique Lima Pinto
SXStanley Soares Xavier
Stanley Soares Xavier
Givago SouzaGivago Souza
Givago Souza
Background: SARS-CoV-2 infection can lead to a variety of persistent sequelae, collectively known as long COVID-19. Deficits in postural balance have been reported in patients several months after COVID-19 infection. The purpose of this study was to evaluate the static balance and balance of individuals with long COVID-19 using inertial sensors in smartphones.Methods: A total of 73 participants were included in this study, of which 41 had long COVID-19 and 32 served as controls. All participants in the long COVID-19 group reported physical complaints for at least 7 months after SARS-CoV-2 infection. Participants were evaluated using a built-in inertial sensor of a smartphone attached to the low back, which recorded inertial signals during a static balance and mobility task (timed up and go test). The parameters of static balance and mobility obtained from both groups were compared.Results: The groups were matched for age and BMI. Of the 41 participants in the long COVID-19 group, 22 reported balance impairment and 33 had impaired balance in the Sharpened Romberg test. Static balance assessment revealed that the long COVID-19 group had greater postural instability with both eyes open and closed than the control group. In the TUG test, the long COVID-19 group showed greater acceleration during the sit-to-stand transition compared to the control group.Conclusion: The smartphone was feasible to identify losses in the balance motor control and mobility of patients with long-lasting symptomatic COVID-19 even after several months or years. Attention to the balance impairment experienced by these patients could help prevent falls and improve their quality of life, and the use of the smartphone can expand this monitoring for a broader population.

1 January 2024 in Anais da Academia Brasileira de Ciências
Verified
Journal Article
Open access
PDF file
TFThaissianne F. Fernandes
Thaissianne F. Fernandes
MVMaria Izabel T.C. Volpe
Maria Izabel T.C. Volpe
FPFrancineide P.S. Pena
Francineide P.S. Pena
ESEnzo Santos
Enzo Santos
GPGustavo Henrique L. Pinto
Gustavo Henrique L. Pinto
Givago SouzaGivago Souza
Givago Souza
It was compared smartphone-based measurements of static balance control and mobility of elderly population with and without type 2 diabetes mellitus (DM2). The present cross-sectional study investigated 73 participants grouped in a control group (n = 36) and a DM2 group (n = 37). Smartphone’s built in inertial sensors were used to record inertial changes of the participants during static balance and mobility (Timed Up and Go test – TUG) tasks. The inertial variations as a function of the time were analyzed and compared between groups. Both groups were matched in age, body mass index, male-female proportion, but DM2 group had significant larger fasting glucose than control group. Additionally, DM2 group had worst static balance control with open and closed eyes than the controls (p < 0.05) as well as they also had longer duration to execute the different events of the mobility test than the controls (p < 0.05). DM2 patients had decline of motor functions compared to controls and the use of bult-in sensors of smartphones was feasible to identify these functional impairments. The easy access of smartphones could be improving the screening of functional impairments in DM2 patients.