Xiaofeng Lu

Prof. Dr. Xiaofeng Lu

Key Laboratory of Low-Grade Energy Utilization Technologies and Systems, Chongqing University, Ministry of Education of PRC, Chongqing 400044, China

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2019 in Energy & Fuels
Verified
Journal Article
Closed access
ZLZhuo Liu
Zhuo Liu
JLjianbo Li
jianbo Li
MZMingming Zhu
Mingming Zhu
QWQuanhai Wang
Quanhai Wang
Xiaofeng LuXiaofeng Lu
Xiaofeng Lu
DZDongke Zhang
Dongke Zhang

1 May 2021 in Energy
Verified
Journal Article
Closed access
Dongfang LiDongfang Li
Dongfang Li
KKKyeongho Kim
Kyeongho Kim
MKMinwoo Kim
Minwoo Kim
YZYijie Zeng
Yijie Zeng
ZYZhongzhi Yang
Zhongzhi Yang
Chung-Hwan JeonChung-Hwan Jeon
Chung-Hwan Jeon


20 December 2017 in Energy & Fuels
Verified
Journal Article
Closed access
YCYe Chen
Ye Chen
Xiaofeng LuXiaofeng Lu
Xiaofeng Lu
WZWenqing Zhang
Wenqing Zhang
QWQuanhai Wang
Quanhai Wang
SCSida Chen
Sida Chen
JLjianbo Li
jianbo Li

7 November 2013 in Energy & Fuels
Verified
Journal Article
Closed access
YKYinhu Kang
Yinhu Kang
Xiaofeng LuXiaofeng Lu
Xiaofeng Lu
QWQuanhai Wang
Quanhai Wang
XJXuanyu Ji
Xuanyu Ji
SMShanshan Miao
Shanshan Miao
HLHai Liu
Hai Liu

25 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
JYJin Yan
Jin Yan
Xiaofeng LuXiaofeng Lu
Xiaofeng Lu
Changfei ZhangChangfei Zhang
Changfei Zhang
QLQianjun Li
Qianjun Li
JWJinping Wang
Jinping Wang
XFXuchen Fan
Xuchen Fan
The unknown NOx distributions inside large-scale CFB (circulating fluidized bed) boilers have always hindered the economy of the SNCR (selective non-catalytic reduction) process. In this study, field tests were carried out on a typical 300 MW CFB boiler, where multi-level 316 L-made probe and Ecom-J2KN/Testo 350 analyzers were used to perform detailed two-dimensional distributions of flue gas composition at SNCR inlets for the first time. The penetration depth inside the horizontal flue pass was up to 7 m. The NOx distributions were analyzed in detail combining with the auxiliary test in the dilute phase zone. Key results show that the average O2 concentrations in #A and #C regions were 6.52% and 0.95%, respectively. The vertical NOx distributions of #A and #C SNCR inlets were similar, showing a trend of first increasing and then decreasing with peak value all appeared at 5 m depth, while the NOx distribution of #B SNCR inlet was basically increasing. Some local areas with extremely high NOx concentration (over 2000 mg/m3) were observed near the inclined edge of SNCR inlets, which has never been reported before. Based on this, the optimization of urea injections was conducted, which could save 15.7% of the urea solution consumption while ensuring ultra-low emission of NOx.