The accurate localization of S1 and S2 is essential for heart sound segmentation and classification. However, current direct heart sound segmentation algorithms have poor noise immunity and low accuracy. Therefore, this paper proposes a new optimal heart sound segmentation algorithm based on K-means clustering and Haar wavelet transform. The algorithm includes three parts. Firstly, this method uses the Viola integral method and Shannon’s energy-based algorithm to extract the function of the envelope of the heart sound energy. Secondly, the time–frequency domain features of the acquired envelope are extracted from different dimensions and the optimal peak is searched adaptively based on a dynamic segmentation threshold. Finally, K-means clustering and Haar wavelet transform are implemented to localize S1 and S2 of heart sounds in the time domain. After validation, the recognition rate of S1 reached 98.02% and that of S2 reached 96.76%. The model outperforms other effective methods that have been implemented. The algorithm has high robustness and noise immunity. Therefore, it can provide a new method for feature extraction and analysis of heart sound signals collected in clinical settings.
Video-based dynamic facial emotion recognition (FER) is a challenging task, as one must capture and distinguish tiny facial movements representing emotional changes while ignoring the facial differences of different objects. Recent state-of-the-art studies have usually adopted more complex methods to solve this task, such as large-scale deep learning models or multimodal analysis with reference to multiple sub-models. According to the characteristics of the FER task and the shortcomings of existing methods, in this paper we propose a lightweight method and design three attention modules that can be flexibly inserted into the backbone network. The key information for the three dimensions of space, channel, and time is extracted by means of convolution layer, pooling layer, multi-layer perception (MLP), and other approaches, and attention weights are generated. By sharing parameters at the same level, the three modules do not add too many network parameters while enhancing the focus on specific areas of the face, effective feature information of static images, and key frames. The experimental results on CK+ and eNTERFACE’05 datasets show that this method can achieve higher accuracy.
22 August 2023 in IEEE Transactions on Biomedical Circuits and Systems
Abnormalities in cardiac function arise irregularly and typically involve multimodal electrical, mechanical vibrations, and acoustics alterations. This paper proposes an Electro-Mechano-Acoustic (EMA) activity model for mapping the complete macroscopic cardiac function to refine the systematic interpretation of cardiac multimodal assessment. We abstract this activity pattern and build the mapping system by analyzing the functional comparison of the heart pump and Electronic Fuel Injection (EFI) system from the multimodal characteristics of the heart. Electrocardiogram (ECG), seismocardiogram (SCG) & Ultra-Low Frequency seismocardiogram (ULF-SCG), and Phonocardiogram (PCG) are selected to implement the EMA mapping respectively. First, a novel low-frequency cardiograph compound sensor capable of extracting both SCG and ULF-SCG is proposed, which is integrated with ECG and PCG modules on a single hardware device for portable dynamic acquisition. Afterward, a multimodal signal processing chain further analyses the acquired synchronized signals, and the extracted ULF-SCG is shown to indicate changes in heart volume. In particular, the proposed method based on waveform curvature is used to extract 9 feature points of the SCG signal, and the overall recognition accuracy reaches over 90% in the data collected by EMA portable device. Ultimately, we integrate the portable device and signal processing chains to form the EMA cardiovascular mapping system (EMACMS). As a next-generation system solution for cardiac daily dynamic monitoring, which can map the mechanical coupling and electromechanical coupling process, extract multi-characteristic heart rate variability (HRV), and enable extraction of important time intervals of cardiac activity to assess cardiac function.
1 January 2016 in Progress in Electromagnetics Research C
This paper proposes a fully integrated broadband power amplifier for LTE-A application using GaAs HBT process. To improve the linearity and broadband performance, RC feedback structures and dynamic bias circuits are employed and designed through optimization. With careful design of the broadband matching networks in the proposed 3-stage power amplifier topology, a power gain above 21.6 dB is achieved from 1.8 GHz to 2.8 GHz. Driven by an 80 MHz wideband LTE-A signal with PAPR of 7.5 dB, the designed RF power amplifier achieves an average output power about 22 dBm at ACLR =-30 dBc over the entire 1 GHz frequency band. Considering the broad bandwidth of the driven signal and wide frequency coverage bandwidth, the performance merits of the proposed design compare favorably with the state-of-the-art.
In response to the application scenarios of modernized Traditional Chinese Medicine (TCM) diagnostic and treatment equipment moving towards the user end, an effort has been made to enhance the user-friendliness of TCM diagnostic and treatment devices. This involves introducing the concept of edge computing into the mobile tongue diagnosis instrument, shifting the tasks of tongue image acquisition and analysis to portable auxiliary diagnostic devices. To improve the efficiency of edge computing devices in handling tongue image analysis tasks, a multi-task network model based on a lightweight network backbone is proposed. The model utilizes the lightweight feature extraction backbone of MobileNet to provide feature encoding for both the semantic segmentation branch and the multi-label classification branch. The semantic segmentation branch adopts a skip-layer connection structure with multi-scale feature maps, and an attention mechanism is incorporated into the classification branch to fuse the feature maps from the segmentation branch. This achieves tongue segmentation and multi-label classification tasks in a computationally efficient environment. The model achieves a pixel accuracy of 85.3% in semantic segmentation and an accuracy of 95.6% in multi-label classification. The network’s forward propagation speed on edge computing platforms reaches 7 frames per second (FPS). The proposed lightweight network backbone multi-task network model ensures a significant improvement in processing efficiency while maintaining the accuracy of segmentation and classification tasks. Additionally, the model exhibits advantages in terms of quantity and scale, saving both storage and computational resources. It not only enhances the accuracy and efficiency of tongue image real-time analysis in edge computing scenarios but also reduces the processing time, providing excellent precision and inference speed.
Cardiovascular diseases pose a long-term risk to human health. This study focuses on the rich-spectrum mechanical vibrations generated during cardiac activity. By combining Fourier series theory, we propose a multi-frequency vibration model for the heart, decomposing cardiac vibration into frequency bands and establishing a systematic interpretation for detecting multi-frequency cardiac vibrations. Based on this, we develop a small multi-frequency vibration sensor module based on flexible polyvinylidene fluoride (PVDF) films, which is capable of synchronously collecting ultra-low-frequency seismocardiography (ULF-SCG), seismocardiography (SCG), and phonocardiography (PCG) signals with high sensitivity. Comparative experiments validate the sensor’s performance and we further develop an algorithm framework for feature extraction based on 1D-CNN models, achieving continuous recognition of multiple vibration features. Testing shows that the recognition coefficient of determination (), mean absolute error (MAE), and root mean square error (RMSE) of the 8 features are 0.95, 2.18 ms, and 4.89 ms, respectively, with an average prediction speed of 60.18 us/point, meeting the re-quirements for online monitoring while ensuring accuracy in extracting multiple feature points. Finally, integrating the vibration model, sensor, and feature extraction algorithm, we propose a dynamic monitoring system for multi-frequency cardiac vibration, which can be applied to portable monitoring devices for daily dynamic cardiac monitoring, providing a new approach for the early diagnosis and prevention of cardiovascular diseases.