Babota Florin

Dr. Babota Florin

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Procedia Manufacturing
Verified
Journal Article
Open access
CAClaudiu Aciu
Claudiu Aciu
DIDana-Adriana Ilutiu-Varvara
Dana-Adriana Ilutiu-Varvara
DMDaniela-Lucia Manea
Daniela-Lucia Manea
YOYvette-Anna Orban
Yvette-Anna Orban
BFBabota Florin
Babota Florin

1 January 2019 in Procedia Manufacturing
Verified
Journal Article
Open access
RIRazvan Andrei Iernutan
Razvan Andrei Iernutan
BFBabota Florin
Babota Florin
RIRaluca Istoan
Raluca Istoan

1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
RIRăzvan Andrei Iernutan
Răzvan Andrei Iernutan
BFBabota Florin
Babota Florin

1 January 2018 in Procedia Manufacturing
Verified
Journal Article
Open access
BFBabota Florin
Babota Florin
DMDaniela Lucia Manea
Daniela Lucia Manea
CAClaudiu Aciu
Claudiu Aciu
CMConstantin Munteanu
Constantin Munteanu
NCNicoleta Cobîrzan
Nicoleta Cobîrzan
DTDaniela Roxana Tămaș-Gavrea
Daniela Roxana Tămaș-Gavrea

1 January 2019 in Procedia Manufacturing
Verified
Journal Article
Open access
RIRazvan Andrei Iernutan
Razvan Andrei Iernutan
BFBabota Florin
Babota Florin

2 April 2018 in Procedia Manufacturing
Verified
Journal Article
Open access
PDF file
BFBabota Florin
Babota Florin
Ligia MogaLigia Moga
Ligia Moga
The present paper investigates the magnitude of the corrected thermal resistance of the slab on the soil in the case of a usual dwelling building in Romania. For computational purposes, the CIMPSPAT software [8] was used; it uses the very accurate numerical method of the thermal balance written in the nodes of the computational grid, according to the provisions of SR EN ISO 10211:2008 [7]. The research was performed for eight variants of thermal insulation layer, with thicknesses varying from 5 to 40cm. When buildings are designed, in general, only the one direction thermal resistances are considered, without taking into account the regulations in Standard C107/2010 [6] and Order no. 2641/2017 [3], which requires specific minimal values for corrected thermal resistances, including thermal bridges, for various construction elements (external walls, external joinery, floors over the last level, slabs on the soil, etc.) [1]. For the slab over the soil, for instance, a thermal insulation layer made of extruded polystyrene of 5, rarely 8 or 10 cm is generally used [1]. This research, performed on a common dwelling building in Romania, aims at finding out the minimal thickness of the thermal insulation layer that meets the requirements of the Norms in C107/2010 [6] and Order no. 2641/2017 [3], that specifies a minimal value for the corrected thermal resistance of the slab over the soil of 4,50 m2·K/W [2].