Compounds that contribute to indoor pollution are regularly investigated due to the fact that people spend most of their time indoors. Worldwide investigations have shown that polycyclic aromatic hydrocarbons (PAHs) are present in indoor dust, but to the best of our knowledge, this paper reports for the first time the presence of PAHs in Croatian households. Eleven PAHs were analysed in house dust samples collected in the city of Zagreb and surroundings (N = 66). Their possible indoor sources and the associated health risks were assessed. Total mass fraction of detected PAHs ranged from 92.9 ng g−1 to 1504.1 ng g−1 (median 466.8 ng g−1), whereby four-ring compounds, Flu and Pyr, contributed the most. DahA was the only compound that did not show statistically significantly positive correlation with other analysed PAHs, indicating that it originated from different sources. Based on diagnostic ratios and principal component analysis (PCA), mixed sources contributed to PAHs levels present in Croatian households. Although our results indicate that Croatian house dusts are weakly polluted with PAHs, total ILCR values calculated for children and adults revealed that people exposed to the highest mass fractions of PAHs measured in this area are at elevated cancer risk.
The toxicity of eight polybrominated diphenyl ethers (PBDEs) congeners detected in environmental and biological samples (BDE-28, -47, -99, -100, -153, -154, -183, and -209) was evaluated on the epithelial lung cells. Exposure to these PBDEs increased membrane disruption and a release of lactate dehydrogenase, accompanied by oxidative stress in cells through the formation of reactive oxygen species (ROS) and a decrease in mitochondrial membrane potential. Interestingly, some of the tested PBDEs increased apoptotic markers as well. For several congeners, the observed toxicity was time dependent, meaning that even smaller concentrations of these compounds will have negative effects over time. Such time-dependent toxicity was also confirmed for cell treatment with a real house dust sample extract. This could be indicative with regard to the constant exposure to a mixture of PBDE congeners through different pathways in the organism and thereby presenting a risk for human health. As such, our findings point to the importance of further studies on the negative effects of PBDEs to understand their mechanism of action in detail.
1 May 2021 in Environmental Toxicology and Pharmacology
Microwave-assisted extraction was applied as a method for extraction of seven polybrominated diphenyl ether (PBDE) congeners (28, 47, 99, 100, 153, 154, and 183) from house dust samples. Optimization of MAE experimental conditions was achieved using a multivariate design approach, and the results indicated that only the choice of extraction solvent had a statistically significant influence on extraction efficiency. The extract purification step was also investigated in detail with a goal to achieve effective cleaning, with minor solvent consumption. As the final operating conditions, 20 min MAE extraction from 1 g of dust with 20 mL of n-hexane : acetone (1 : 1, v/v) at 80 °C and extract purification on an in-lab prepared column containing 2 g of neutral silica and 4 g of acidified silica, whereby the PBDEs were eluted from the column with 15 mL of n-hexane : dichloromethane (4 : 1, v/v), were selected. The extracts were analyzed on a dual GC-μECD system, and GC-MS/MS was used as a confirmatory method. The performance of the optimized method was validated by analyzing spiked dust samples and a standard reference material (NIST 2585 “Organic Contaminants in House Dust”). Congener specific PBDE recovery ranged from 76% to 90% for the spiked samples (with very good repeatability; RSD < 7%) and the measured mass concentrations of selected PBDEs were in excellent agreement with certified values for a standard reference material. The proposed method was successfully applied to the analysis of targeted PBDEs in house dust samples.