The recovery process of COVID-19 patients is unclear. Some recovered patients complain of continued shortness of breath. Vasculopathy has been reported in COVID-19, stressing the importance of probing microstructure and function of lungs at the alveolar-capillary interface. While CT detects structural abnormalities, little is known about the impact of disease on lung function. 129Xe MRI is a technique uniquely capable of assessing ventilation, microstructure and gas exchange. Using 129Xe MRI, we found COVID-19 patients have higher ventilation defects percentage (5.9% vs 3.7%), unchanged microstructure, longer gas-blood exchange time (43.5 ms vs 32.5 ms), and reduced RBC/TP (0.279 vs 0.330) compared with healthy subjects. These findings suggest regional ventilation and alveolar airspace dimensions are relatively normal around the time of discharge, while gas-blood exchange function is diminished. This study establishes the feasibility of localized lung function measurement in COVID-19 patients. Such readouts could be useful as a supplement to structural imaging.
Background and purpose We investigated the baseline demographics of patients with severe unilateral atherosclerotic stenosis of the middle cerebral artery (MCA) using multimodal MRI and evaluated the haemodynamic impairments and plaque characteristics of patients who had a recurrent stroke. Materials and methods We retrospectively recruited consecutive patients with severe unilateral atherosclerotic MCA stenosis who underwent arterial spin labelling (ASL) with postlabelling delay (PLD) of 1.5 and 2.5 s, and vessel wall MRI. For each PLD, cerebral blood flow (CBF) maps were generated. Hypoperfusion volume ratio (HVR) from 2 PLD CBF was calculated. An HVR value ≥50% was considered as severe HVR. Plaque areas, plaque burden, plaque length and remodelling index were measured. Plaque enhancement at maximal lumen narrowing site were graded. Baseline clinical and imaging characteristics were compared between patients with (event+) and without (event−) 1 year ischaemic events. Results Forty-three patients (47.23±12.15 years; 28 men) were enrolled in this study. Seven patients had an HVR ≥50%. During the 1-year follow-up, 7 patients had experienced a recurrent stroke. HVR were significantly higher in the event+ than event− (53.17%±29.82% vs 16.9%±15.57%, p=0.0002), whereas no significant difference was detected in plaque areas, plaque burden, remodelling index, plaque length and plaque enhancement grade. The multivariable analysis revealed that a severe HVR was significantly associated with a recurrent stroke (Odds ratio=12.93, 95% confidence interval 1.57 to 106.24, p=0.017) after adjusted by hypertension and smoking. Conclusion HVR obtained from two PLD ASL may be a useful imaging predictor of recurrent stroke.
• Multi-frequency therapeutic ultrasound enhances sonication bioeffects. • Bioeffects enhancement increases treatment efficiency and decreases requirements on ultrasound device. • The mechanism behind is not yet fully understood, and could be a combination of multiple mechanisms. • Each of the multi-frequency implementations is favored for particular tasks. • No general principle on frequency selection and number of frequencies is concluded, requiring further researches.