Over the last three to four decades, several methods for assessing groundwater vulnerability to anthropogenic pollution have been developed. Researchers and policymakers have widely used these methods for preventing groundwater pollution through knowledge about particularly vulnerable areas. This systematic review presents different and significant methods for assessing the vulnerability of aquifers for the protection of the resource. Previous studies mentioned that formulating a single technique for assessing groundwater vulnerability is difficult; thus, different methods and techniques have been proposed. Therefore, this paper presents three methods, namely, DRASTIC, GOD, and susceptibility index (SI), which will be discussed in detail, and highlights their advantages and limitations. In doing so, the study introduces the concept of aquifer vulnerability, and further discussion will be devoted to the three methods. Lastly, the study outlines the major challenges to the assessment of aquifer vulnerability. The review concludes the importance of groundwater vulnerability and strategies for preserving its quality.
This study evaluated three index-overlay methods (i.e., DRASTIC, GOD, and susceptibility index (SI)) for their suitability to assessing the vulnerability of shallow aquifer in southeast Hungary to contamination from the land surface. Accordingly, the most recent information on the shallow aquifer depth, recharge rate, land use, and geology/hydrogeology of the groundwater basin was created and integrated in a geographic information system and through a linear combination to compose the methods indices. All three methods delineated approximately 95% of the groundwater basin as being moderately to highly susceptible to contamination, which was mainly due to the sandy soil, high recharge rate, gentle topography, and agricultural activities related to land use. A positive linear correlation was also found, during the validation of the final vulnerability maps, between the vulnerability indices and observed nitrate concentration. The vulnerability indices of SI, DRASTIC, and GOD showed correlations of 0.5635, 0.3615, and 0.3499, respectively, with the available nitrate concentration in the groundwater. Thus, SI was concluded as the most suitable method for assessing the vulnerability of shallow aquifers in southeast Hungary to contamination. The outcomes of this study provide useful information that will help policymakers identify the main contributors to groundwater contamination as well as adopt effective management strategies to avoid further pressure on this invaluable resource.
A hierarchical fuzzy inference system (FIS) integrated with the DRASTIC model is applied in this study to enhance the assessment of shallow groundwater vulnerability in southeast Hungary, a region characterized by extensive agriculture and industrial growth. Traditional groundwater vulnerability models often struggle with parameter imprecision and uncertainty, affecting their reliability. To address these limitations, fuzzy logic was incorporated to refine the classification of vulnerability zones. The hierarchical FIS incorporates the seven DRASTIC parameters: depth to the water table, net recharge, aquifer media, soil media, topography, vadose zone impact, and hydraulic conductivity, assigning flexible ratings through fuzzy membership functions. The model classifies the fuzzy groundwater vulnerability index (FGWVI) into low, moderate, and high categories, revealing that 63.9% of the study area is highly susceptible to contamination, particularly in regions with shallow water tables and sandy soils. Validation was conducted using nitrate (NO3−) concentrations and electrical conductivity (EC) measurements from 46 agricultural wells to assess the correlation between predicted vulnerability zones and actual groundwater quality indicators. The correlation analysis revealed a moderately strong positive relationship between FGWVI and both NO3− (R2 = 0.4785) and EC (R2 = 0.528), supporting the model’s ability to identify high-risk contamination zones. This study highlights the effectiveness of the fuzzy-enhanced DRASTIC model in evaluating aquifer vulnerability and provides crucial insights to assist policymakers in identifying pollution sources and developing strategies to mitigate groundwater contamination, thereby alleviating the stress on this critical resource.
The quality of newly constructed pavement depends mostly on compaction, which is essential for ensuring the pavement’s longevity and performance. Traditional methods of evaluating pavement compaction and density, such as core sampling and nuclear gauge measurements, are often time-consuming and invasive and provide only a limited amount of data at a low spatial resolution on the potential air void content of the asphalt layers. The present study aimed to assess the specific gravity (Gmb) of a dolomitic asphalt mixture at different degrees of compaction using GPR techniques. Relative density (RD) maps were generated to visualize the spatial homogeneity of the asphalt density. Nuclear density gauging was applied for the calibration, and cores were used to validate the results. The survey was conducted on two recently paved roads in Szeged, Hungary. After testing various approaches, it was found that applying horn antennas and the surface reflection (SR) method is the most feasible way to obtain reliable and accurate dielectric permittivity (ε) data. Based on the measurements, clear relationships were found between dielectric constants, Gmb, and aggregate size. The findings highlight that it is possible to indirectly determine the Gmb of asphalts composed of dolomite and limestone aggregates using GPR, with aggregate sizes ranging from 11 mm to 25 mm and Gmb values between 2.43 and 2.57 g/cm3. Consequently, a robust function was developed, which can be applied to other asphalts with similar compositions.