Hypothermic Oxygenated Perfusion (HOPE) of the liver can reduce the incidence of early allograft dysfunction (EAD) and failure in extended criteria donors (ECD) grafts, although data from prospective studies are very limited. In this monocentric, open‐label study, from December 2018 to January 2021, 110 patients undergoing transplantation of an ECD liver graft were randomized to receive a liver after HOPE or after static cold storage (SCS) alone. The primary endpoint was the incidence of EAD. The secondary endpoints included graft and patient survival, the EASE risk score, and the rate of graft or other graft‐related complications. Patients in the HOPE group had a significantly lower rate of EAD (13% vs. 35%, p = .007) and were more frequently allocated to the intermediate or higher risk group according to the EASE score (2% vs. 11%, p = .05). The survival analysis confirmed that patients in the HOPE group were associated with higher graft survival one year after LT (p = .03, log‐rank test). In addition, patients in the SCS group had a higher re‐admission and overall complication rate at six months, in particular cardio‐vascular adverse events (p = .04 and p = .03, respectively). HOPE of ECD grafts compared to the traditional SCS preservation method is associated with lower dysfunction rates and better graft survival.
With the aim to explore innovative tools for organ preservation, especially in marginal organs, we hereby describe a clinical trial of ex-vivo hypothermic oxygenated perfusion (HOPE) in the field of liver (LT) and kidney transplantation (KT) from Extended Criteria Donors (ECD) after brain death. A matched-case analysis of donor and recipient variables was developed: 10 HOPE-ECD livers and kidneys (HOPE-L and HOPE-K) were matched 1:3 with livers and kidneys preserved with static cold storage (SCS-L and SCS-K). HOPE and SCS groups resulted with similar basal characteristics, both for recipients and donors. Cumulative liver and kidney graft dysfunction were 10% (HOPE L-K) vs. 31.7%, in SCS group (p = 0.05). Primary non-function was 3.3% for SCS-L vs. 0% for HOPE-L. No primary non-function was reported in HOPE-K and SCS-K. Median peak aspartate aminotransferase within 7-days post-LT was significantly higher in SCS-L when compared to HOPE-L (637 vs.344 U/L, p = 0.007). Graft survival at 1-year post-transplant was 93.3% for SCS-L vs. 100% of HOPE-L and 90% for SCS-K vs. 100% of HOPE-K. Clinical outcomes support our hypothesis of machine perfusion being a safe and effective system to reduce ischemic preservation injuries in KT and in LT.
The poor availability of kidney for transplantation has led to a search for new strategies to increase the donor pool. The main option is the use of organs from extended criteria donors. We evaluated the effects of hypothermic oxygenated perfusion (HOPE) with and without extracellular vesicles (EV) derived from mesenchymal stromal cells on ischemic/reperfusion injury of marginal kidneys unsuitable for transplantation. For normothermic reperfusion (NR), we used artificial blood as a substitute for red blood cells. We evaluated the global renal ischemic dam-age score (GRS), analyzed the renal ultrastructure (RU), cytochrome c oxidase (COX) IV-1 (a mitochondrial distress marker), and caspase-3 renal expression, the tubular cell proliferation index, hepatocyte growth factor (HGF) and vascular endothelial growth factor (VEGF) tissue levels, and effluent lactate and glucose levels. HOPE+EV kidneys had lower GRS and better RU, higher COX IV-1 expression and HGF and VEGF levels and lower caspase-3 expression than HOPE kidneys. During NR, HOPE+EV renal effluent had lower lactate release and higher glucose levels than HOPE renal effluent, suggesting that the gluconeogenesis system in HOPE+EV group was pre-served. In conclusion, EV delivery during HOPE can be considered a new organ preservation strategy for increasing the donor pool and improving transplant outcome.
Background: Extended criteria donors (ECD) are widely utilized due to organ shortage, but they may increase the risk of graft dysfunction and poorer outcomes. Hypothermic oxygenated perfusion (HOPE) is a recent organ preservation strategy for marginal kidney and liver grafts, allowing a redirect from anaerobic metabolism to aerobic metabolism under hypothermic conditions and protecting grafts from oxidative species–related damage. These mechanisms may improve graft function and survival. Objective: With this study, we will evaluate the benefit of end-ischemic HOPE on ECD grafts for livers and kidneys as compared to static cold storage (SCS). The aim of the study is to demonstrate the ability of HOPE to improve graft function and postoperative outcomes of ECD kidney and liver recipients. Methods: This is an open-label, single-center randomized clinical trial with the aim of comparing HOPE with SCS in ECD kidney and liver transplantation. In the study protocol, which has been approved by the ethics committee, 220 patients (110 liver recipients and 110 kidney recipients) will be enrolled. Livers and kidneys assigned to the HOPE group undergo machine perfusion with cold Belzer solution (4-10°C) and continuous oxygenation (partial pressure of oxygen of 500-600 mm Hg). In the control group, livers and kidneys undergoing SCS are steeped in Celsior solution and stored on ice. Using the same perfusion machine for both liver and kidney grafts, organs are perfused from the start of the back-table procedure until implantation, without increasing the cold ischemia time. For each group, we will evaluate clinical outcomes, graft function tests, histologic findings, perfusate, and the number of allocated organs. Publication of the results is expected to begin in 2021. Results: Dynamic preservation methods for organs from high-risk donors should improve graft dysfunction after transplantation. To date, we have recruited 108 participants. The study is ongoing, and recruitment of participants will continue until January 2020. Conclusions: The proposed preservation method should improve ECD graft function and consequently the postoperative patient outcomes. Trial Registration: ClinicalTrials.gov NCT03837197; https://clinicaltrials.gov/ct2/show/NCT03837197 ; Archived by WebCite® at http://www.webcitation.org/76fSutT3R International Registered Report Identifier (IRRID): DERR1-10.2196/13922