Marwa Emam

Prof. Marwa Emam

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2023 in Dental and Medical Problems
Verified
Journal Article
Open access
MEMarwa Emam
Marwa Emam
LGLomaya Ghanem
Lomaya Ghanem
HSHoda Sadek
Hoda Sadek
The trueness of intraoral scanners (IOSs) has been evaluated in many clinical situations. However, the tests of their performance when scanning post-space preparations are still lacking. The aim of the present study was to compare the trueness of the digital impressions of post spaces with different depths, captured by means of different IOSs. Digital impressions of teeth (N = 16) with post spaces of depths of 8 mm and 10 mm were captured. Three IOSs were used, including Primescan AC, Medit i500 and CS 3600. The STL files were compared to the files obtained from the traditional impression scanning performed with an InEos X5 desktop scanner. Then, reverse engineering software measured the trueness values, which were analyzed using the two-way analysis of variance (ANOVA), followed by Tukey's post-hoc test. The significance level was set at p < 0.05. Significant differences were found between the scanners in terms of root mean square (RMS) values (p < 0.001). The highest RMS value was found for CS 3600 (0.30 ±0.11 mm), followed by Primescan AC (0.26 ±0.09 mm), while the lowest value was found for Medit i500 (0.18 ±0.05 mm). The 8-millimeter-deep post spaces had a significantly higher RMS value than the 10-millimeter-deep ones (0.28 ±0.10 mm and 0.21 ±0.09 mm, respectively) (p = 0.009). The Medit i500 scanner showed the highest post-space digital impression trueness as compared to Primescan AC and CS 3600. In the digital impressions captured with CS 3600, the 10 mm postspace depth had higher trueness than the 8 mm depth. Moreover, CS 3600 was less able to capture the full length of both the 8 mm and 10 mm post-space depths than Primescan AC and Medit i500.

11 May 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
MEMarwa Emam
Marwa Emam
AAAhmed Mohamed Arafa
Ahmed Mohamed Arafa
Background: It is unclear which crown materials are optimum to disperse the generated stresses around dental implants. The objective of this study is to assess stress distribution and fracture resistance of green reprocessed Polyetheretherketone (PEEK) in comparison to un-reprocessed PEEK and zirconia single implant crown restorations. Methods: Twenty crowns (n = 20) were obtained, five from zirconia and fifteen from pressed PEEK that were subdivided into 3 groups of five specimens each (n = 5) according to weight% of reprocessed material used. A 100% new PEEK was used for the first group, 50% new and 50% reprocessed PEEK were used for the second group, and a 100% reprocessed PEEK was used for the third group. Epoxy resin model with dental implant in the second mandibular premolar was constructed with strain gauges located mesially and distally to the implant to record strain while a load of 100 N was applied with 0.5 mm/min then specimens of all groups were vertically loaded till failure in a universal testing machine at cross head speed 1 mm/min. Data was statistically analyzed by using One-way Analysis of Variance (ANOVA) followed by Post-hoc test when ANOVA test is significant. Results: No significant difference between strain values of tested groups (p = 0.174) was noticed. However, a significant difference between fracture resistance values was noticed where the zirconia group recorded a significantly higher value (p < 0.001). Conclusions: Implant restorative materials with different moduli of elasticity have similar effects regarding stresses distributed through dental implant and their surrounding bone. Reprocessed PEEK implant restorations transmit similar stresses to dental implant and surrounding bone as non-reprocessed PEEK and zirconia restorations. Zirconia failed at higher load values than all tested PEEK restorations but all can be safely used in the posterior area as crown restorations for single implants. Clinical relevance: Applying “green dentistry” principles may extend to include reprocessing of pressed PEEK restorative materials without affecting the material’s shock absorption properties.

9 August 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
MEMarwa Emam
Marwa Emam
MMMohamed F. Metwally
Mohamed F. Metwally
Background: Insufficient research has been conducted in the literature assessing the performance of zirconia and polyetheretherketone (PEEK) crowns in relation to the essential requirements of successful restorations, such as fracture resistance or margin adaptation. The purpose of this study was to evaluate the effect of the coping materials zirconia or PEEK with different fabrication techniques on the vertical marginal gap and fracture resistance of posterior crowns with composite veneering. Methods: Ceramic copings (n = 18) restoring mandibular first molar were fabricated from zirconia (Zircon.x, Presidentdental, Germany), milled PEEK (PEEK CAD) (breCAM.BioHPP, Bredent, Germany) and pressed PEEK (PEEK Press) (BioHPP Granules, Bredent, Germany) six specimens each (n = 6). The copings were veneered with high impact polymer composite (HIPC) material (breCAM.HIPC, Bredent, Germany). The vertical marginal gap was captured under a magnification of 40X. Five equidistant marks on each surface of the die distinguished the points of measurement for a total of 20 readings per sample. The analysis was completed using an image analysis system (ImageJ 1.53t, National Institute of Health, USA). The specimens were loaded to failure at a crosshead speed of 1 mm/min and the load at failure was recorded to measure the fracture resistance. Results: The marginal gap was analyzed using one-way ANOVA followed by Tukey’s post hoc test. Fracture resistance was analyzed using Welch one-way ANOVA followed by the Games-Howell post hoc test. Marginal gap values showed a significant difference between the tested groups, with zirconia having significantly lower gap values (48.67 ± 11.98 µm) than both the PEEK CAD (108.00 ± 20.08 µm) and Press groups (108.00 ± 25.10 µm) (p < 0.001). However, the results of fracture resistance showed no significant difference (p = 0.06) with 1687.47 ± 253.29 N, 2156.82 ± 407.64 N, 2436.72 ± 725.93 N for zirconia, PEEK CAD, and Press, respectively. The significance level was p < 0.05. Conclusions: Zirconia framework crowns have a smaller vertical marginal gap than milled and pressed PEEK crowns. Crowns fabricated from zirconia, PEEK CAD, or PEEK Press frameworks and veneered with composite resin have comparable fracture resistance lower than the maximum biting force in the posterior region. Clinical relevance: Posterior crowns with zirconia frameworks are preferred over milled and pressed PEEK frameworks regarding margin adaptation, although all can safely survive the maximum occlusal forces without fracture.

22 March 2025 in Journal of Dentistry
Verified
Journal Article
Closed access
AMAsmaa Mostafa
Asmaa Mostafa
HSHoda M. Abdel Sadek
Hoda M. Abdel Sadek
AHAmina Hamdy
Amina Hamdy
MEMarwa Emam
Marwa Emam

1 July 2022 in Egyptian Dental Journal
Verified
Journal Article
Closed access
PDF file
AAAhmed Arafa
Ahmed Arafa
MEMarwa Emam
Marwa Emam
Purpose: to evaluate the effect of repeated heat pressing on fracture resistance and mode of failure analysis of new and reprocessed PEEK either partially or totally 3-unit FDPs. Methods: 15 PEEK FDPs were manufactured and divided into 3 groups (n=5). Group I was pressed using new PEEK, Group II; 50% new PEEK and 50% reprocessed PEEK, and Group III; 100% reprocessed PEEK. The FDPs were vertically loaded till failure in a universal testing machine. Failed specimens were examined for mode of failure and microstructural analysis with SEM and XRD. Results: There was a statistically significant difference between mean fracture resistance values of different PEEK conditions (P-value = 0.006, Effect size = 0.577). Pair-wise comparisons between conditions revealed no statistically significant difference between new (1719.6±315.7) and partially reprocessed PEEK (2010.4±444.4); both showed statistically significant higher mean fracture resistance than totally reprocessed PEEK (1097.2±319.5). Mode of failure analysis showed only bending in the new PEEK group bending (100%). While in the partially processed PEEK group 40% of the samples showed visible cracks at the connector area. Finally, in the totally processed PEEK group 80% showed complete fracture. Conclusion: Totally reprocessed PEEK 3-unit FDPs had the lowest fracture resistance compared to new and partially reprocessed PEEK although all exceeded maximum occlusal forces recorded in the molar area. Incorporating reprocessed PEEK material in 3-unit FDPs increased brittleness and decreased their ability to deform and absorb stresses created during force application.

9 December 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MEMarwa Emam
Marwa Emam
LKLudger Keilig
Ludger Keilig
CBChristoph Bourauel
Christoph Bourauel