Jisoo Hwang

Dr. Jisoo Hwang


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2018 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Jong-Min YeomJong-Min Yeom
Jong-Min Yeom
Jonghan KoJonghan Ko
Jonghan Ko
JHJisoo Hwang
Jisoo Hwang
CLChang Suk Lee
Chang Suk Lee
Chuluong ChoiChuluong Choi
Chuluong Choi
SJSeungtaek Jeong
Seungtaek Jeong
Radiometric calibration of satellite imaging sensors should be performed periodically to account for the effect of sensor degradation in the space environment on image accuracy. In this study, we performed vicarious radiometric calibrations (relying on in situ data) of multispectral imaging sensors on the Korea multi-purpose satellite-3 and -3A (KOMPSAT-3 and -3A) to adjust the existing radiometric conversion coefficients according to time delay integration (TDI) adjustments and sensor degradation over time. The Second Simulation of a Satellite Signal in the Solar Spectrum (6S) radiative transfer model was used to obtain theoretical top of atmosphere radiances for both satellites. As input parameters for the 6S model, surface reflectance values of well-characterized pseudo-invariant tarps were measured using dual ASD FieldSpec® 3 hyperspectral radiometers, and atmospheric conditions were measured using Microtops II® Sunphotometer and Ozonometer. We updated the digital number (DN) of the radiance coefficients of the satellites; these had been used to calibrate the sensors during in-orbit test periods in 2013 and 2015. The coefficients of determination, R2, values between observed DNs of the sensors, and simulated radiances for the tarps were more than 0.999. The calibration errors were approximately 5.7% based on manifested error sources. We expect that the updated coefficients will be an important reference for KOMPSAT-3 and -3A users.

19 December 2008 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JHJisoo Hwang
Jisoo Hwang
DLDong-Hoon Lee
Dong-Hoon Lee
SPSeongchong Park
Seongchong Park
YKYong-Wan Kim
Yong-Wan Kim
SPSeung-Nam Park
Seung-Nam Park
We present a measurement uncertainty evaluation for emission color and luminance of displays. The calibration procedures and the measurement uncertainties of a CCD-based spectroradiometer and a filter-type luminance meter are discussed. As evaluation examples, a Commission Internationale de l’ Éclairage illuminant A, a liquid-crystal display with a light-emitting diode backlight, and a liquid-crystal display with a cold-cathode fluorescent lamp backlight are evaluated. The uncertainties in Commission Internationale de l’ Éclairage 1931 (x,y) chromaticity coordinates are determined to be in a range from 0.0020 to 0.0050 (k=2). The uncertainties in luminance are obtained from 4.8% to 8.5% by using the spectroradiometer, while the filter-type luminance meter shows the uncertainties from 1.1% to 1.6% (k=2).

4 February 2017 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Jong-Min YeomJong-Min Yeom
Jong-Min Yeom
JHJisoo Hwang
Jisoo Hwang
JJJae-Heon Jung
Jae-Heon Jung
KLKwonho Lee
Kwonho Lee
CLChang Suk Lee
Chang Suk Lee
On-orbit radiometric characterization of the multispectral (MS) imagery of the Korea Aerospace Research Institute (KARI)’s Korea Multi-Purpose Satellite-3A (KOMPSAT-3A), which was launched on 25 March 2015, was conducted to provide quantitative radiometric information about KOMPSAT-3A. During the in-orbit test (IOT), vicarious radiometric calibration of KOMPSAT-3A was performed using the Second Simulation of a Satellite Signal in the Solar Spectrum (6S) radiative transfer model. The characteristics of radiometric tarps, the atmospheric optical depth from multi-filter rotating shadowband radiometer (MFRSR) measurements, and sun–sensor–geometry were carefully considered, in order to calculate the exact top of atmosphere (TOA) radiance received by KOMPSAT-3A MS bands. In addition, the bidirectional reflectance distribution function (BRDF) behaviors of the radiometric tarps were measured in the laboratory with a two-dimensional hyperspectral gonioradiometer, to compensate for the geometry discrepancy between the satellite and the ASD FieldSpec® 3 spectroradiometer. The match-up datasets between the TOA radiance and the digital number (DN) from KOMPSAT-3A were used to determine DN-to-radiance conversion factors, based on linear least squares fitting for two field campaigns. The final results showed that the R2 values between the observed and simulated radiances for the blue, green, red, and near-infrared (NIR) bands, are greater than 0.998. An approximate error budget analysis for the vicarious calibration of KOMPSAT-3A showed an error of less than 6.8%. When applying the laboratory-based BRDF correction to the case of higher viewing zenith angle geometry, the gain ratio was improved, particularly for the blue (1.3%) and green (1.2%) bands, which exhibit high sensitivity to the BRDF of radiometric tarps during the backward-scattering phase. The calculated gain ratio between the first and second campaigns showed a less than 5% discrepancy, indicating that the determined radiometric characteristics of KOMPSAT-3A are reliable and useful to the user group for quantitative applications.

16 September 2014 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JHJisoo Hwang
Jisoo Hwang
A new instrument for absolute measurement of hyperspectral and angular reflection is presented. The instrument determines absolute values of angular reflection quantities in a wavelength range from 380 to 780 nm with a 3 nm spectral resolution by using a white source and a CCD-based spectroradiometer. Through uncertainty evaluation, the measurement uncertainty is determined as 1.4%–2.9% (k=2) for white diffuse material of Spectralon. The gonioreflectometric determination and an integrating-sphere-based reflection measurement traceable to KRISS spectral reflectance scale are compared by determining hemispherical reflectance, which results in agreement in their uncertainties.

6 September 2013 in Metrologia
Verified
Journal Article
Closed access
JHJisoo Hwang
Jisoo Hwang
HCHehree Cho
Hehree Cho
DSDong-Joo Shin
Dong-Joo Shin
KJKi Lyong Jeong
Ki Lyong Jeong

7 October 2016 in Metrologia
Verified
Journal Article
Closed access
PDF file
JHJisoo Hwang
Jisoo Hwang
DSDong-Joo Shin
Dong-Joo Shin
KJKi Ryong Jeong
Ki Ryong Jeong
We investigate the comparison method and the substitution method of integrating sphere-based relative methods for reflection measurements. Through an analytical description, we compare the two methods with a focus on the effects of a sphere: to determine reflectance without any correction on a sphere, the substitution method requires symmetry of a sphere in addition to the requirement of the comparison method, either uniformity of a sphere or equal reflectance distribution between a sample and a reference. We experimentally compare the two methods through reflection measurements of gray-scale diffuse samples with reflectance of 10%, 40%, and 99%, which results in agreement within their measurement uncertainties. Also, we observe a reflectance change depending on sample location on a sphere in the substitution type measurements, which is attributed to sphere’s lack of symmetry. The experimental results are analyzed in terms of measurement uncertainty and reflection properties including bidirectional reflectance distribution function.