Lene Terslev

Prof. Dr. Lene Terslev

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2007 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
CWCharlotte Wiell
Charlotte Wiell
MSMarcin Szkudlarek
Marcin Szkudlarek
MHMaria Hasselquist
Maria Hasselquist
JMJakob M Møller
Jakob M Møller
AVAage Vestergaard
Aage Vestergaard
MØMikkel Østergaard
Mikkel Østergaard
The aim of the present study was to assess ultrasonography (US) for the detection of inflammatory and destructive changes in finger and toe joints, tendons, and entheses in patients with psoriasis-associated arthritis (PsA) by comparison with magnetic resonance imaging (MRI), projection radiography (x-ray), and clinical findings. Fifteen patients with PsA, 5 with rheumatoid arthritis (RA), and 5 healthy control persons were examined by means of US, contrast-enhanced MRI, x-ray, and clinical assessment. Each joint of the 2nd–5th finger (metacarpophalangeal joints, proximal interphalangeal [PIP] joints, and distal interphalangeal [DIP] joints) and 1st–5th metatarsophalangeal joints of both hands and feet were assessed with US for the presence of synovitis, bone erosions, bone proliferations, and capsular/extracapsular power Doppler signal (only in the PIP joints). The 2nd–5th flexor and extensor tendons of the fingers were assessed for the presence of insertional changes and tenosynovitis. One hand was assessed by means of MRI for the aforementioned changes. X-rays of both hands and feet were assessed for bone erosions and proliferations. US was repeated in 8 persons by another ultrasonographer. US and MRI were more sensitive to inflammatory and destructive changes than x-ray and clinical examination, and US showed a good interobserver agreement for bone changes (median 96% absolute agreement) and lower interobserver agreement for inflammatory changes (median 92% absolute agreement). A high absolute agreement (85% to 100%) for all destructive changes and a more moderate absolute agreement (73% to 100%) for the inflammatory pathologies were found between US and MRI. US detected a higher frequency of DIP joint changes in the PsA patients compared with RA patients. In particular, bone changes were found exclusively in PsA DIP joints. Furthermore, bone proliferations were more common and tenosynovitis was less frequent in PsA than RA. For other pathologies, no disease-specific pattern was observed. US and MRI have major potential for improved examination of joints, tendons, and entheses in fingers and toes of patients with PsA.

17 November 2011 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
FGFrédérique Gandjbakhch
Frédérique Gandjbakhch
LTLene Terslev
Lene Terslev
FJFredrick Joshua
Fredrick Joshua
RWRichard J Wakefield
Richard J Wakefield
ENEsperanza Naredo
Esperanza Naredo
OFOmeract Ultrasound Task Force
Omeract Ultrasound Task Force
Introduction: An increasing number of studies have applied ultrasound to the evaluation of entheses in spondyloarthritis patients. However, no clear agreement exists on the definition of enthesitis, on the number and choice of entheses to examine and on ultrasound technique, which may all affect the results of the examination. The objectives of this study were to first determine the level of homogeneity in the ultrasound definitions for the principal lesions of enthesitis in the published literature and second, to evaluate the metric properties of ultrasound for detecting enthesitis according to the OMERACT filter. Methods: Search was performed in PUBMED and EMBASE. Both grey-scale and Doppler definitions of enthesitis, including describing features of enthesitis, were collected and metrological qualities of studies were assessed. Results: After selection, 48 articles were analyzed. The definition of ultrasound enthesitis and elementary features varied among authors. Grey-scale enthesitis was characterized by increasing thickness (94% of studies), hypoechogenicity (83%), enthesophytes (69%), erosions (67%), calcifications (52%), associated bursitis (46%) and cortical irregularities (29%). Only 46% of studies reported the use of Doppler. High discrepancies were observed on frequency, type of probe and Doppler mode used. Face and content validity were the most frequently evaluated criteria (43%) followed by reliability (29%) and responsiveness (19%). Conclusions: Ultrasound has evidence to support face, content validity and reliability for the evaluation of enthesitis, though there is a lack of well-reported methodology in most of the studies. Consensus on elementary lesions and standardization of exam is needed to determine the ultrasound definition of enthesitis in grey-scale and in Doppler for future applications.

17 June 2013 in Ultraschall in der Medizin - European Journal of Ultrasound
Verified
Journal Article
Closed access
PDF file
LTLene Terslev
Lene Terslev
HHH. B. Hammer
H. B. Hammer
STS. Torp-Pedersen
S. Torp-Pedersen
MSM. Szkudlarek
M. Szkudlarek
AIA. Iagnocco
A. Iagnocco
ENE. Naredo
E. Naredo
The middle name abbreviation of the author G. A. Bruyn was changed.

15 October 2015 in The Journal of Rheumatology
Verified
Journal Article
Closed access
PDF file
LTLene Terslev
Lene Terslev
MGMarwin Gutierrez
Marwin Gutierrez
RCRobin Christensen
Robin Christensen
PBPeter V. Balint
Peter V. Balint
GBGeorge A. Bruyn
George A. Bruyn
WSWolfgang A. Schmidt
Wolfgang A. Schmidt
Objective.: To test the reliability of the consensus-based ultrasound (US) definitions of elementary gout lesions in patients.Methods.: Eight patients with microscopically proven gout were evaluated by 16 sonographers for signs of double contour (DC), aggregates, erosions, and tophi in the first metatarsophalangeal joint and the knee bilaterally. The patients were examined twice using B-mode US to test agreement and inter- and intraobserver reliability of the elementary components.Results.: The prevalence of the lesions were DC 52.8%, tophus 61.1%, aggregates 29.8%, and erosions 32.4%. The intraobserver reliability was good for all lesions except DC, where it was moderate. The best reliability per lesion was seen for tophus (κ 0.73, 95% CI 0.61–0.85) and lowest for DC (κ 0.53, 95% CI 0.38–0.67). The interobserver reliability was good for tophus and erosions, but fair to moderate for aggregates and DC, respectively. The best reliability was seen for erosions (κ 0.74, 95% CI 0.65–0.81) and lowest for aggregates (κ 0.21, 95% CI 0.04–0.37).Conclusion.: This is the first step to test consensus-based US definitions on elementary lesions in patients with gout. High intraobserver reliability was found when applying the definition in patients on all elementary lesions while interobserver reliability was moderate to low. Further studies are needed to improve the interobserver reliability, particularly for DC and aggregates.

20 July 2017 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
LTLene Terslev
Lene Terslev
ADA. P. Diamantopoulos
A. P. Diamantopoulos
UDU. Møller Døhn
U. Møller Døhn
WSW. A. Schmidt
W. A. Schmidt
STS. Torp-Pedersen
S. Torp-Pedersen
Ultrasound is used increasingly for diagnosing large vessel vasculitis (LVV). The application of Doppler in LVV is very different from in arthritic conditions. This paper aims to explain the most important Doppler parameters, including spectral Doppler, and how the settings differ from those used in arthritic conditions and provide recommendations for optimal adjustments. This is addressed through relevant Doppler physics, focusing, for example, on the Doppler shift equation and how angle correction ensures correctly displayed blood velocity. Recommendations for optimal settings are given, focusing especially on pulse repetition frequency (PRF), gain and Doppler frequency and how they impact on detection of flow. Doppler artefacts are inherent and may be affected by the adjustment of settings. The most important artefacts to be aware of, and to be able to eliminate or minimize, are random noise and blooming, aliasing and motion artefacts. Random noise and blooming artefacts can be eliminated by lowering the Doppler gain. Aliasing and motion artefacts occur when the PRF is set too low, and correct adjustment of the PRF is crucial. Some artefacts, like mirror and reverberation artefacts, cannot be eliminated and should therefore be recognised when they occur. The commonly encountered artefacts, their importance for image interpretation and how to adjust Doppler setting in order to eliminate or minimize them are explained thoroughly with imaging examples in this review.

20 April 2021 in RMD Open
Verified
Journal Article
Open access
PDF file
VFViktoria Fana
Viktoria Fana
UDUffe M Dohn
Uffe M Dohn
SKSimon Krabbe
Simon Krabbe
LTLene Terslev
Lene Terslev
Aim To describe salivary gland involvement in patients suspected of Sjögren’s syndrome (SS) using the OMERACT Ultrasound Scoring System for SS. Next, using different ultrasound cut-offs, to assess the performance of the scoring system for diagnosis and fulfilment of 2016 ACR/EULAR SS classification criteria. Methods All patients referred to our department with a suspicion of SS in a 12-month period were included. All underwent grey-scale ultrasound of the parotid and submandibular glands prior to clinical examination, Schirmer’s test, unstimulated salivary flow, blood samples including autoantibody analysis. Labial biopsy was performed according to clinicians’ judgement. Images of the four glands were scored 0–3 according to the scoring system and a consensus score was obtained using a developed ultrasound atlas. Results Of the 134 patients included in the analysis, 43 were diagnosed with primary SS (pSS) and all fulfilled the 2016 American College of Rheumatology (ACR)/EULAR classification criteria. More patients with pSS compared with non-pSS had score ≥2 in at least one gland (72% vs 13%; p2 in at least one gland. Our data supports the use of ultrasound for diagnosing pSS and supports incorporation of ultrasound in the classification criteria.