Mostafa Omran Hussein

Dr. Mostafa Omran Hussein

Qassim University, Buraidah, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MHMostafa Omran Hussein
Mostafa Omran Hussein

1 January 2022 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
MHMostafa Omran Hussein
Mostafa Omran Hussein
LHLamis Ahmed Hussein
Lamis Ahmed Hussein
Hussein MO, et al. J Adv Prosthodont. 2022 Jun;14(3):150-161. https://doi.org/10.4047/jap.2022.14.3.150

21 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
MHMostafa Omran Hussein
Mostafa Omran Hussein
LELamis Ahmed Hussein Enaba
Lamis Ahmed Hussein Enaba
The optimal three-dimensional (3D) printing parameters of removable partial denture (RPD) frameworks should be studied to achieve the best accuracy, printing time, and least materials consumed. This study aimed to find the best build angle and support structures’ diameter of the 3D printed (RPD) framework. Sixty (RPD) frameworks (10 in each group) were manufactured by digital light processing (DLP) 3D printing technology at three build angles (110-D, 135-D, and 150-D) and two support structures diameters (thick, L, and thin, S). Six groups were named according to their printing setting as (110-DS, 135-DS, 150-DS, 110-DL, 135-DL, and 150-DL). Frameworks were 3D scanned and compared to the original cast surface using 3D metrology software (Geomagic Control X; 3D Systems, Rock Hill, SC). Both printing time and material consumption were also recorded. Data were tested for the significant difference by one-way analysis of variance (ANOVA) test at (α = 0.05). The correlations between outcome parameters were also calculated. The 110-DL group showed the least accuracy. Significantly, the printing time of the 150-D groups had the lowest time. Material consumption of group 110-DS presented the lowest significantly statistical value. Printing time had a linear correlation with both accuracy and material consumption. Within the study limitations, the 150-degree build angle and thin diameter support structures showed optimal accuracy and time-saving regardless of material consumption.

31 October 2015 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
AAAlaa Abdelhamid
Alaa Abdelhamid
MHMostafa Omran Hussein
Mostafa Omran Hussein
NBNeema Bakhshalian
Neema Bakhshalian
DTDennis Tarnow
Dennis Tarnow
HZHomayoun H. Zadeh
Homayoun H. Zadeh

1 April 2015 in Journal of Oral Implantology
Verified
Journal Article
Closed access
MHMostafa Omran Hussein
Mostafa Omran Hussein
MRMahmoud Elsayed Rabie
Mahmoud Elsayed Rabie
The All-on-4 design was used successfully for restoring edentulous mandible. This design avoids anatomic cripples such as inferior alveolar nerve by tilting posterior implants. Moreover, tilting posterior implants of All-on-4 design had a mechanical preference than the conventional design. On the other hand, the anterior implants are parallel at the lateral incisor region. Several researches showed favorable results for tilting posterior implants. However, research did not study the influence of the anterior implant position or orientation on the mechanical aspects of this design. This study analyzes the influence of varying anterior implant position and orientation of the All-on-4 design using nonlinear contact 3D finite-element analysis. Three copied 3-dimensional models of the All-on-4 design were classified according to anterior implant position and orientation. The frictional contact between fixtures and bone was the contact type in this finite element analysis. Finally, von Mises stress and strain at implant and bone levels were recorded and analyzed using finite element software. Stress concentrations were detected mainly around the posterior implant at the loaded side. Values of the maximum equivalent stress and strain were around tilted implants of design III followed by design II, then design I. Changing the position or orientation of the anterior implants in All-on-4 design influences stress-strain distribution of the whole design.

23 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
MHMostafa Omran Hussein
Mostafa Omran Hussein
The esthetic clasp material is a clinical demand for a satisfactory removable partial denture. The purpose of this study is to assess the mechanical performance of graphene-based polymer (GBP) and polyether-ether-ketone (PEEK) materials as clasp materials. Thirty-two clasps were fabricated by CAD-CAM from two materials, GBP and PEEK. All clasps were tested for retention force after 10,000 cycles of insertion and removal and thermocycling. The clasp arms’ deformation was measured, and areas of stress–strain concentration were explored. The Mann–Whitney U test was used to compare the retentive force of the studied groups, while the independent sample t-test was applied to check the difference in clasp arm deformation at α = 0.5. The results showed a significantly higher retentive force (2.248 ± 0.315 N) in PEEK clasps, at p < 0.001. The deformation of the clasp arm of the GBP clasps was significantly higher than PEEK clasps. Areas of stress–strain concentration were seen at the junction of the retentive arm to the minor connector and at the retentive arm terminal. It could be concluded that PEEK polymer had a better mechanical performance as an esthetic clasp material than the GBP. An optimization study for GBP might be required to check the validity of such an application.