The optimal three-dimensional (3D) printing parameters of removable partial denture (RPD) frameworks should be studied to achieve the best accuracy, printing time, and least materials consumed. This study aimed to find the best build angle and support structures’ diameter of the 3D printed (RPD) framework. Sixty (RPD) frameworks (10 in each group) were manufactured by digital light processing (DLP) 3D printing technology at three build angles (110-D, 135-D, and 150-D) and two support structures diameters (thick, L, and thin, S). Six groups were named according to their printing setting as (110-DS, 135-DS, 150-DS, 110-DL, 135-DL, and 150-DL). Frameworks were 3D scanned and compared to the original cast surface using 3D metrology software (Geomagic Control X; 3D Systems, Rock Hill, SC). Both printing time and material consumption were also recorded. Data were tested for the significant difference by one-way analysis of variance (ANOVA) test at (α = 0.05). The correlations between outcome parameters were also calculated. The 110-DL group showed the least accuracy. Significantly, the printing time of the 150-D groups had the lowest time. Material consumption of group 110-DS presented the lowest significantly statistical value. Printing time had a linear correlation with both accuracy and material consumption. Within the study limitations, the 150-degree build angle and thin diameter support structures showed optimal accuracy and time-saving regardless of material consumption.
Objective: The objective of the study is to measure the in vitro retention overall pull-off force of telescopic crowns made from two different materials and with different taper angles. Materials and methods: The telescopic crowns were digitally fabricated from two materials, Polyether-ether ketone (PEEK) disc and graphene-nano reinforced acrylic disc (GN) at three taper angles (0˚, 1˚ & 2˚). Retention force for each specimen was measured 20 times in a pull off- Test, the machine was set to a crosshead speed 50 mm/min applying tension mode of force up to crown dislodgement. Twenty cycles of insertion and removal were performed for each sample and then the retention force was computed and recorded using computer software. Statistical analysis was carried out using Two-way analysis of variance (ANOVA) to explore the effect of different materials and degree of taper on the retention load. Independent sample t-test was conducted to explore the difference between materials. Results: The retention force of 2 ° taper showed a statistically significant lower value than 0° and 1° tapers. The specimens of the PEEK groups showed significantly higher initial retentive force values than (GN) groups. Conclusions: Telescopic crowns fabricated from PEEK milled material showed better retention force than the GN milled material. Increasing the degree of taper angle of the telescopic crown above 1° could jeopardize the resultant retention. However, long-term clinical studies are still recommended
Background. Polymethylmethacrylate (PMMA) is commonly used for dental appliances, however, it has several shortcomings that could be addressed. Ganoderma Lucidum (G. Lucidum) material has a desirable antifungal effect and may also enhance the mechanical strength of PMMA materials. Objective. The purpose of this study was to assess the flexural strength, modulus of elasticity and antifungal activity of the PMMA modified by G. Lucidum. Material and methods. Forty-eight specimens were prepared as two groups, group 1: PMMA (control), group 2: PMMA modified by G. Lucidum. Flexural strength and antifungal activity were assessed followed by scanning by confocal laser scanning microscopy (CFLSM). Modulus of elasticity was also calculated for both groups. Data were collected and statistically tested using one-way analysis of variance (ANOVA) to check the difference between groups followed by Bonferroni's post-hoc test for pairwise comparison. Result: Group 2 showed higher flexural strength and modulus of elasticity (59.62155± 8.99716 MPa), (2943.82±702.2 MPa) respectively. Broth micro dilution assay of group 2 showed the microbial inhibited concentration (MIC) values were ≥ 375 μg/ml for Candida Albicans. This was also confirmed by the (CFLSM) by showing increased dead C. Albicans cells. Conclusion. It can be concluded that the modification of PMMA with G. Lucidum can increase some mechanical properties and antifungal activity of the PMMA material.