The knowledge of the distribution of the electric field within and around high voltage equipment is a crucial aspect of the design, exploitation and performance of high voltage insulators. It could be useful for the detection of defects in insulators. The objective of this study is predicting the...
2 April 2023 in Engineering, Technology & Applied Science Research
This article introduces a grid-connected photovoltaic (PV) source combined with a multi-level inverter. A converter five-level neutral point (NPC) can be used to integrate the PV power into the power grid with minimum harmonic distortions and high power capacity. If the output voltage of the PV generator varies significantly with solar radiation, the output voltage of the ripple must be fixed. For this reason, a regulation loop was used. In this study, we used a classical PI regulator. It is difficult to determine the PI controller transaction values, so Genetic Algorithm was used to optimize the PI controller parameters. The Matlab/Simulink simulation results show the better performance and efficiency of the PI controller optimized by the GA, in comparison to the stand-alone PI controller, regarding stability and accuracy, and the reduction of Total Harmonic Distortions (THD) of the current injected into the grid for any difference in solar radiation.
The flashover of pollution, observed on the insulators used in high voltage transmission, is one of the most important power transmission stakes. It is a very complex problem due to several factors including the modelling difficulties of complex shapes of insulators, different pollution densities...
The knowledge of the behavior of both the electric potential and electric field is one of the main factors needed when designing an insulator. Using AutoCAD software a 2D cap and pin 1512L insulator model was created in the clean state and under pollution from one to five insulators separately...
In this paper, the response surface methodology (RSM) is used to predict the flashover voltage of a cap and pin 1512L insulator used by SONELGAZ Algerian Power Company (SPE). The pollution and conductivity are studied using a two-level central composite design. MINITAB 19 software is used to perform the regression analysis and analysis of variance (ANOVA) of the data, from which the full quadratic model is developed. The results show that both the pollution and conductivity have a significant effect on the response. The model validation shows the good agreement between the experiment’s obtained results and the predicted results. Therefore, the model could be used to predict the flashover voltage.