Kevin D. D Martin

Kevin D. D Martin


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2016 in Arthroscopy
Verified
Journal Article
Closed access
KMKevin D. D Martin
Kevin D. D Martin
DPDavid P. Patterson
David P. Patterson
KCKenneth L. Cameron
Kenneth L. Cameron

11 March 2015 in Foot & Ankle International
Verified
Journal Article
Closed access
KMKevin D. D Martin
Kevin D. D Martin
DPDavid Patterson
David Patterson
PPPhinit Phisitkul
Phinit Phisitkul
KCKenneth L. Cameron
Kenneth L. Cameron
JFJohn Femino
John Femino
AAAnnunziato Amendola
Annunziato Amendola
The purpose of this study was to determine whether low-fidelity arthroscopic simulation training improves basic ankle arthroscopy performance and efficiency among orthopedic trainees. Twenty-nine orthopedic surgery trainees with varying levels of experience in ankle arthroscopy were randomized into either simulation or standard practice groups. At baseline testing, all participants performed simulator-based testing and a cadaveric diagnostic ankle arthroscopy with video recording. The simulation group subsequently received 4 one-on-one, 15-minute simulation training sessions over a 4-month period, while the standard practice group received no additional simulation training or exposure. After intervention, both groups were reevaluated with simulator testing and a second recorded cadaveric diagnostic ankle arthroscopy. Two blinded, independent experts evaluated each randomized arthroscopic performance using the 15-point checklist, Arthroscopic Surgery Skill Evaluation Tool (ASSET), and total elapsed time, and all outcome measures were compared within and between groups. Baseline arthroscopic experience, simulator task performance measures, and ASSET scores were equivalent between the simulation and standard practice groups. After completion of training, the simulation group outscored the control group in total ASSET score (34.9 vs 19.6; P < .001) and checklist score (14.5 vs 8.4; P < .001) and achieved nearly expert ASSET Safety scores (4.7 vs 2.9; P < .001) on the simulator model. Cadaver testing also demonstrated significant improvements in total ASSET score (28.8 vs 16.8; P < .001), checklist score (12.6 vs 7.1; P < .001), and ASSET Safety score (3.9 vs 2.6; P < .001). These results demonstrate that low-fidelity ankle arthroscopy simulation training can improve basic surgical skills, efficiency of movement, and anatomic recognition. The results suggest greater patient safety during ankle arthroscopy following simulation training. Level I, prospective comparative study.

5 October 2020 in Foot & Ankle International
Verified
Journal Article
Closed access
PDF file
KMKevin D. D Martin
Kevin D. D Martin
NANolan N. Andres
Nolan N. Andres
WRWilliam H. Robinson
William H. Robinson
Immediately following a lateral ligament reconstruction of the ankle, the strength of the repair is far less than that of the native anterior talofibular ligament (ATFL). Additionally, early functional rehabilitation has been shown to increase laxity of the repair. We hypothesized that a Broström procedure augmented with a suture-tape construct would allow early functional rehabilitation while maintaining patient reported outcomes within a military population. This study is a retrospective study of 93 consecutive patients with chronic lateral ankle instability that were treated with a Broström procedure augmented with a suture-tape construct. Subjects were evaluated at 2, 6, and 12 weeks postoperatively, with yearly satisfaction reviews. Demographics and functional outcomes including Foot and Ankle Disability Index (FADI), visual analog scale (VAS), satisfaction score, and clinical measures including single-leg hop and single-leg heel raise were recorded. Our patients included 75 males and 18 females with a mean age of 30 ± 7 (range, 19-51) years; our mean follow-up was 19 (range, 3-48) months. The mean FADI score improved from 67 preoperatively to 87 and 90 at 6 and 12 weeks (P < .001), with 60 patients (65%) obtaining a score greater than 90. The mean VAS scores improved from 4.8 preoperatively to 1.4 and 1.3 at 6 and 12 weeks (P < .001). Eighty-two (96%) of the patients asked were able to complete a single-leg hop and single-leg heel raise at 6 weeks. The 12-, 24-, 36-, and 48-month satisfaction scores were 8.5, 9.8, 9.2, and 8.9, respectively. Demographics collected did not impact results. This study suggests that a Broström procedure augmented with suture tape enabled early safe functional rehabilitation without subsequent failure. Our data also demonstrated a sustained high level of patient satisfaction while preventing reoccurrence within a high-demand military population. Level IV, retrospective case series.

3 October 2020 in Foot & Ankle International
Verified
Journal Article
Closed access
PDF file
KMKevin D. D Martin
Kevin D. D Martin
CTCourtney T. Tripp
Courtney T. Tripp
JHJeannie Huh
Jeannie Huh
Background: Posterior malleolar fractures within a trimalleolar ankle fracture pattern are challenging to manage. Posterior ankle arthroscopy provides a means to assess the intra-articular and syndesmotic reductions, while removing loose bodies. The purpose of this study was to determine the radiographic and patient reported outcomes of posterior arthroscopic reduction and internal fixation (PARIF) in trimalleolar ankle fractures. Methods: From November 2015 to March 2019, we prospectively enrolled consecutive trimalleolar ankle fractures that underwent PARIF by a single surgeon. Preoperative and postoperative computed tomography (CT) scans were interpreted by 2 blinded musculoskeletal radiologists for articular reduction, syndesmosis congruity, and presence of ossific loose bodies. Patient outcomes were assessed using the Foot and Ankle Disability Index (FADI), American Orthopaedic Foot & Ankle Society (AOFAS) ankle score, Olerud-Molander Ankle Score (OMAS), and visual analog scale (VAS). A total of 28 trimalleolar ankle fractures were treated with PARIF. Mean patient age was 36 years (range, 19-69). Results: Preoperative CT identified 18 intra-articular loose bodies (range, 0-4) in 36% of ankles and 75% (n = 21) syndesmosis incongruity. Postoperative CT scans demonstrated anatomic intra-articular reduction in all fractures, 41.7% (5/12) syndesmosis incongruity without fixation, and 0% (0/9) with suture-button fixation. At mean 2-year follow-up, the results were good to excellent with mean VAS score 1 (range, 0-4), AOFAS score 84 (range, 63-100), FADI 85 (range, 59-100), and OMAS 76 (range, 40-100). Conclusion: The PARIF technique for displaced posterior malleolar fractures was effective in achieving anatomic intra-articular reduction, syndesmosis congruity, and intra-articular loose body removal, while safely preserving the soft tissues. Level of Evidence: Level IV, prospective case series.

1 October 2021 in Foot & Ankle Orthopaedics
Verified
Journal Article
Open access
PDF file
CDCuyler Dewar
Cuyler Dewar
TGTerry L. Grindstaff
Terry L. Grindstaff
BFBrooke Farmer
Brooke Farmer
MSMorgan Sainsbury
Morgan Sainsbury
SGSam Gay
Sam Gay
KMKevin D. D Martin
Kevin D. D Martin
Foot and ankle injuries frequently require a period of nonweightbearing, resulting in muscle atrophy. Our previous study compared a hands-free single crutch (HFSC) to standard axillary crutches and found increased muscle recruitment and intensity while using the HFSC. Knee scooters are another commonly prescribed nonweightbearing device. The purpose of this study is to examine the electromyographic (EMG) differences between an HFSC and knee scooter, in conjunction with device preference and perceived exertion. A randomized crossover study was performed using 30 noninjured young adults. Wireless surface EMG electrodes were placed on the belly of the rectus femoris (RF), vastus lateralis (VL), lateral gastrocnemius (LG), and gluteus maximus (GM). Participants then ambulated along a 20-m walking area while 15 seconds of the gait cycle was recorded across 3 conditions: walking with a knee scooter, an HFSC, and with no assistive device. Mean muscle activity and peak EMG activity were recorded for each ambulatory modality. Immediately following testing, patient exertion and device preference was recorded. The RF, LG, and GM showed increased peak EMG activity percentage, and the LG showed increased mean muscle activity while using the HFSC compared with the knee scooter. When comparing the knee scooter and HFSC to walking, both showed increased muscle activity in the RF, VL, and LG but no difference in the GM. There was no statistical difference in participant preference, whereas the HFSC had a statistically significant higher perceived exertion than the knee scooter (P < .001). In this group of young, healthy noninjured volunteers, the HFSC demonstrated increased peak EMG activity in most muscle groups tested compared with the knee scooter. Level II, prospective comparative study.

11 December 2019 in Foot & Ankle International
Verified
Journal Article
Closed access
PDF file
KMKevin D. D Martin
Kevin D. D Martin
Posterior malleolus fractures and pilon variants refer to a pattern of fractures involving the posterior weightbearing surface of the tibial plafond. The surgical indications for fixation of posterior malleolus fractures varies considerably throughout the literature, based on the size and/or displacement. There is controversy on how to best address fracture fixation, with the main workhorses being either the posterior-lateral approach or indirect anterior-posterior–directed screws. We present an alternative technique for posterior malleolus fracture fixation using a direct posterior arthroscopic-assisted reduction internal fixation method. With this method, posterior malleolus fractures are reduced arthroscopically and percutaneous fixation is placed through the arthroscopic portals. Level of Evidence: Level V, expert opinion