30 December 2020 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
LHLili He
Lili He
ZSZhikang Shuai
Zhikang Shuai
Xu ChuXu Chu
Xu Chu
WHWen Huang
Wen Huang
YFYu Feng
Yu Feng
ZSZheng John John Shen
Zheng John John Shen
Unlike conventional synchronous generators, the fault characteristics of inverter-based distributed generators (IBDGs) are mainly determined by the inverter control strategies. Their limited fault current contributions make the protection design of islanded microgrids (MGs) become a major challenge. This paper focuses on the fault characteristics and protection scheme design of islanded MGs. First, the phase differences between the positive-sequence current fault components (PSC-FCs) at both terminals of fault line are analyzed under different network topologies and fault severities. It points out the phase characteristic differences between internal and external faults. Then, on basis of this, to overcome the problems of the phase measurement error and protection setting, a waveform difference feature-based protection scheme is proposed. The protection criteria are formulated using the first peak sign and time information of PSC-FCs between both terminals of line, which are extracted by the mathematical morphology (MM) technology. Only relatively low bandwidth communication is required to achieve accurate fault identification. Finally, the simulation results on a 10-kV islanded MG model demonstrate that the proposed scheme can identify internal faults reliably in both looped and radial islanded MGs under different fault resistances and measurement noises.


18 May 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
LHLili He
Lili He
YLYang Li
Yang Li
Xu ChuXu Chu
Xu Chu
ZSZhikang Shuai
Zhikang Shuai
YPYelun Peng
Yelun Peng
ZSZheng John John Shen
Zheng John John Shen
Considering single-phase to ground (SPG) faults accounting for more than 80% of all faults, neutral ineffectively grounded mode (NIGM) is the most promising choice for medium voltage (MV) islanded microgrids (MGs) to enhance operation reliability. But due to the weak fault current and flexible network topology of islanded MGs, it is difficult to detect SPG fault lines. To solve this issue, this paper firstly analyzes the SPG fault characteristics of the MV islanded MGs with different NIGMs and network topologies. It is found that the looped MGs have a virtual terminal, i.e., the point where zero-sequence current (ZSC) is zero. And the feature differences between fault and non-fault lines are revealed. Based on that, an SPG fault line identification method is proposed. The main criterion is constructed based on the skewness signs of high frequency zero-sequence voltage (ZSV) and ZSC. Additionally, the fundamental amplitude of the difference between the actual ZSC received from another terminal and the ZSC calculated from local ZSV and ZSC is used to formulate an auxiliary criterion. Finally, the effectiveness of the proposed method is validated in a 10kV islanded MG model considering different NIGMs, different fault conditions, arc grounding faults, and the influences of the line parameter, operating point and measurement noises.


7 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Xu ChuXu Chu
Xu Chu
QLQi Liu
Qi Liu
LFLetian Fu
Letian Fu
SYShaoshuai Yu
Shaoshuai Yu
WWWeidong Wang
Weidong Wang
Sensors in power systems utilize the detection results of fault signals to guide subsequent fault handling procedures. However, the traditional phase-shift restart strategy exhibits limitations such as power interruptions, reactive power redundancy, and intersystem fault clearance failures when addressing faults in the hybrid AC/DC transmission system. To address these shortcomings, a power compensation-based fault ride-through (FRT) scheme and a protection-control cooperation FRT scheme are proposed, taking into account the operational characteristics of the symmetric monopole LCC-HVDC (SM-LCC-HVDC). The power compensation-based FRT scheme actively compensates for power, mitigating the impact of reactive power redundancy on the AC-side bus during faults. The protection-control cooperation FRT scheme is activated after sufficient AC components are detected on the DC side. It leverages the adjustability of the DC system to proactively activate protection for AC transmission lines. An electromagnetic transient simulation model of the hybrid AC/DC same-tower transmission system was developed in PSCAD/EMTDC. Simulation results validate the effectiveness and superiority of the proposed methods.