Robert Bansemer

Dr. Robert Bansemer

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2016 in Plasma Processes and Polymers
Verified
Journal Article
Closed access
PDF file
ASAnsgar Schmidt-Bleker
Ansgar Schmidt-Bleker
RBRobert Bansemer
Robert Bansemer
SRStephan Reuter
Stephan Reuter
KWKlaus-Dieter Weltmann
Klaus-Dieter Weltmann

16 October 2020 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
ETEric Timmermann
Eric Timmermann
RBRobert Bansemer
Robert Bansemer
TGTorsten Gerling
Torsten Gerling
VHVeronika Hahn
Veronika Hahn
KWKlaus-Dieter Weltmann
Klaus-Dieter Weltmann
MPMarkus Puff
Markus Puff
A commercial air-fed and piezoelectric-driven plasma pen (piezobrush ® , relyon plasma GmbH, Regensburg, Germany) including three different nozzles was investigated for its suitability as a medical plasma device. In this regard, potential risk factors for human health, which originate from gas temperature, thermal output, patient leakage current, ultraviolet radiation and gas emissions, were assessed according to DIN SPEC 91315:2016–06. As a result, safe treatment distances were determined for each nozzle. The antimicrobial efficacy was investigated subsequently by inhibition zone assays with five different clinical relevant microorganisms. All results were compared to an approved medical plasma source fed with argon (kINPen ® MED, neoplas tools GmbH, Greifswald, Germany). It was observed that the antimicrobial efficacy differs not only between the two devices as a result from different feed gases, but also between the nozzles. This could be traced back to a different plasma chemistry, which accompanying Fourier-transform infrared absorption spectroscopy suggests. The measured physical properties of the piezoelectric plasma pen at the determined operating parameters do not show human health risks. Due to its distinct antimicrobial efficacy, the piezoelectric plasma pen shows a high potential for a medical application.

2 November 2018 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
JWJörn Winter
Jörn Winter
TNThaita Nishime
Thaita Nishime
RBRobert Bansemer
Robert Bansemer
MBMartina Balazinski
Martina Balazinski
KWKristian Wende
Kristian Wende
KWKlaus-Dieter Weltmann
Klaus-Dieter Weltmann
Based on a capacitively coupled plasma jet concept, an enhanced atmospheric pressure plasma jet setup for endoscopic applications is presented. Besides the favourable features of small dimension, flexibility and ability to operate in hollow bodies, new approaches for low patient leakage current, enhanced biological efficacy and reduced material erosion are subject of this work. It is found that a combination of neon feed gas, CO 2 shielding gas and a current limited high voltage supply gives the best bactericidal results and, at the same time, reduces material erosion as well as patient leakage current.

17 November 2015 in Plasma Sources Science and Technology
Verified
Journal Article
Open access
PDF file
MDM Dünnbier
M Dünnbier
MBM M Becker
M M Becker
SIS Iseni
S Iseni
RBRobert Bansemer
Robert Bansemer
DLD Loffhagen
D Loffhagen
KWK-D Weltmann
K-D Weltmann

10 September 2018 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
LHLuka Hansen
Luka Hansen
ASAnsgar Schmidt-Bleker
Ansgar Schmidt-Bleker
RBRobert Bansemer
Robert Bansemer
HKHolger Kersten
Holger Kersten
Klaus-Dieter WeltmannKlaus-Dieter Weltmann
Klaus-Dieter Weltmann
SRStephan Reuter
Stephan Reuter
In this work a cold atmospheric pressure plasma jet was mounted above a distilled water reservoir to study the influence of a water surface on reactive oxygen and nitrogen species (RONS) generation. The RONS, namely O 3 and NO 2 , were measured by multi-pass cell Fourier transform infrared absorption spectroscopy in the far-field of the jet. A shielding gas device was used to control the ambient environment of the effluent. The liquid surface has nearly no influence on the RONS dynamics as a function of shielding gas composition. It was found, however, that the interaction with the liquid surface increases the density of NO x by a factor of 2–3 due to local increase in H 2 O concentration through evaporation of water from the liquid surface. In contrast to the case of ambient humidity increase, this locally higher H 2 O density distinctly influences the ratio of water to oxygen and nitrogen which results in a higher generation of OH molecules.

5 May 2017 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
PDF file
RBRobert Bansemer
Robert Bansemer
ASAnsgar Schmidt-Bleker
Ansgar Schmidt-Bleker
Ursula van RienenUrsula van Rienen
Ursula van Rienen
KWKlaus-Dieter Weltmann
Klaus-Dieter Weltmann
A novel flow-driven dielectric barrier discharge concept is presented, which uses a Venturi pump to transfer plasma-generated reactive oxygen and nitrogen species from a sub-atmospheric pressure ( 200 – 600 mbar ) discharge region to ambient pressure and can be operated with air. By adjusting the working pressure of the device, the plasma chemistry can be tuned continuously from an ozone ( O 3 )-dominated mode to a nitrogen oxides ( NO x )-only mode. The plasma source is characterized focusing on the mechanisms effecting this mode change. The composition of the device’s output gas was determined using Fourier-transform infrared spectroscopy. The results are correlated to measurements of discharge chamber pressure and temperature as well as of input power. It is found that the mode-change temperature can be controlled by the discharge chamber pressure. The source concept is capable of generating an NO x -dominated plasma chemistry at gas temperatures distinctly below 400 K . Through mixing of the processed gas stream with a second flow of pressurized air required for the operation of the Venturi pump, the resulting product gas stream remains close to room temperature. A reduced zero-dimensional reaction kinetics model with only seven reactions is capable of describing the observed pressure- and temperature-dependence of the O 3 to NO x mode-change.