Naglaa Kamel Bahgaat

Dr. Naglaa Kamel Bahgaat

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in International Journal of System Dynamics Applications
Verified
Journal Article
Closed access
PDF file
NBNaglaa Kamel Bahgaat
Naglaa Kamel Bahgaat
MEM. I. El-Sayed
M. I. El-Sayed
MHMohamed Hassan
Mohamed Hassan
FBF. A. Bendary
F. A. Bendary
The main objective of Load Frequency Control (LFC) is to regulate the power output of the electric generator within an area in response to changes in system frequency and tie-line loading. Thus the LFC helps in maintaining the scheduled system frequency and tie-line power interchange with the other areas within the prescribed limits. Most LFCs are primarily composed of an integral controller. The integrator gain is set to a level that compromises between fast transient recovery and low overshoot in the dynamic response of the overall system. This type of controller is slow and does not allow the controller designer to take into account possible changes in operating conditions and non-linearities in the generator unit. Moreover, it lacks robustness. This paper studies LFC in two areas power system using PID controller. In this paper, PID parameters are tuned using different tuning techniques. The overshoots and settling times with the proposed controllers are better than the outputs of the conventional PID controllers. This paper uses MATLAB/SIMULINK software. Simulations are done by using the same PID parameters for the two different areas because it gives a better performance for the system frequency response than the case of using two different sets of PID parameters for the two areas. The used methods in this paper are: a) Particle Swarm Optimization, b) Adaptive Weight Particle Swarm Optimization, c) Adaptive Acceleration Coefficients based PSO (AACPSO) and d) Adaptive Neuro Fuzzy Inference System (ANFIS). The comparison has been carried out for these different controllers for two areas power system. Therefore, the article presents advanced techniques for Load Frequency Control. These proposed techniques are based on Artificial Intelligence. It gives promising results.

4 October 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NBNaglaa Kamel Bahgaat
Naglaa Kamel Bahgaat
With the increasing of global awareness of the importance of reducing polluting emissions and maintaining a clean and healthy environment. So, the tendency to generate electric energy from new and renewable sources has become an urgent need to achieve this goal. In this paper an optimal economic cost analysis using hybrid renewable energy sources to generate the electricity needed for long-term evolution mobile phone systems was estimated. The proposed electric system accounts for the reduction of polluting emissions to the environment. The electrical profile of the optimal approaches or the hybrid technology and traditional methods which contain solar photovoltaic’, batteries, wind turbines, diesel generator were estimated and provides the electrical power for a Long-Term Evolution mobile network (LTE) as the load at a remote located area. A real time optimal cost analysis of each proposed network is done based on the real load profile, wind speed and solar radiation was placid on from 6 October city in Egypt. Statistical analysis was performed by varying the systems through comparison to determine the optimal approaches based on the Hybrid Optimization Model for Electrical Renewables software (HOMER).

20 May 2022 in Entropy
Verified
Journal Article
Open access
PDF file
ITIlham Toumi
Ilham Toumi
BMbillel meghni
billel meghni
OHOussama Hachana
Oussama Hachana
ASA. S.
A. S.
ABAmira Boulmaiz
Amira Boulmaiz
NBNaglaa Kamel Bahgaat
Naglaa Kamel Bahgaat
In order to extract efficient power generation, a wind turbine (WT) system requires an accurate maximum power point tracking (MPPT) technique. Therefore, a novel robust variable-step perturb-and-observe (RVS-P&O) algorithm was developed for the machine-side converter (MSC). The control strategy was applied on a WT based permanent-magnet synchronous generator (PMSG) to overcome the downsides of the currently published P&O MPPT methods. Particularly, two main points were involved. Firstly, a systematic step-size selection on the basis of power and speed measurement normalization was proposed; secondly, to obtain acceptable robustness for high and long wind-speed variations, a new correction to calculate the power variation was carried out. The grid-side converter (GSC) was controlled using a second-order sliding mode controller (SOSMC) with an adaptive-gain super-twisting algorithm (STA) to realize the high-quality seamless setting of power injected into the grid, a satisfactory power factor correction, a high harmonic performance of the AC source, and removal of the chatter effect compared to the traditional first-order sliding mode controller (FOSMC). Simulation results showed the superiority of the suggested RVS-P&O over the competing based P&O techniques. The RVS-P&O offered the WT an efficiency of 99.35%, which was an increase of 3.82% over the variable-step P&O algorithm. Indeed, the settling time was remarkably enhanced; it was 0.00794 s, which was better than for LS-P&O (0.0841 s), SS-P&O (0.1617 s), and VS-P&O (0.2224 s). Therefore, in terms of energy efficiency, as well as transient and steady-state response performances under various operating conditions, the RVS-P&O algorithm could be an accurate candidate for MPP online operation tracking.

2 March 2015
Verified
Book Chapter
Closed access
NBNaglaa Kamel Bahgaat
Naglaa Kamel Bahgaat
MEM. I. El-Sayed
M. I. El-Sayed
MHMohamed Hassan
Mohamed Hassan
FBF. A. Bendary
F. A. Bendary
The main objective of Load Frequency Control (LFC) is to regulate the power output of the electric generator within an area in response to changes in system frequency and tie-line loading. Thus the LFC helps in maintaining the scheduled system frequency and tie-line power interchange with the other areas within the prescribed limits. Most LFCs are primarily composed of an integral controller. The integrator gain is set to a level that compromises between fast transient recovery and low overshoot in the dynamic response of the overall system. This type of controller is slow and does not allow the controller designer to take into account possible changes in operating conditions and non-linearities in the generator unit. Moreover, it lacks robustness. This paper studies LFC in two areas power system using PID controller. In this paper, PID parameters are tuned using different tuning techniques. The overshoots and settling times with the proposed controllers are better than the outputs of the conventional PID controllers. This paper uses MATLAB/SIMULINK software. Simulations are done by using the same PID parameters for the two different areas because it gives a better performance for the system frequency response than the case of using two different sets of PID parameters for the two areas. The used methods in this paper are: a) Particle Swarm Optimization, b) Adaptive Weight Particle Swarm Optimization, c) Adaptive Acceleration Coefficients based PSO (AACPSO) and d) Adaptive Neuro Fuzzy Inference System (ANFIS). The comparison has been carried out for these different controllers for two areas power system. Therefore, the article presents advanced techniques for Load Frequency Control. These proposed techniques are based on Artificial Intelligence. It gives promising results.

16 April 2016
Verified
Book Chapter
Closed access
PDF file
NBNaglaa Kamel Bahgaat
Naglaa Kamel Bahgaat
MHMohamed Hassan
Mohamed Hassan
ASA. S.
A. S.

30 April 2017 in International Journal of Grid and Distributed Computing
Verified
Journal Article
Closed access
AMA.ELrheem E.A. Mostafa
A.ELrheem E.A. Mostafa
NBNaglaa Kamel Bahgaat
Naglaa Kamel Bahgaat
MSMohamed Ebrahim El Sayed
Mohamed Ebrahim El Sayed
EOEl-Said A. Othman
El-Said A. Othman