Introduction: Chest deformation has been proposed as the best predictor of thoracic injury risk in frontal impacts. Finite Element Human Body Models (FE-HBM) can enhance the results obtained in physical crash tests with Anthropometric Test Devices (ATD) since they can be exposed to omnidirectional impacts and their geometry can be modified to reflect specific population groups. This study aims to assess the sensitivity of two thoracic injury risk criteria (PC Score and Cmax) to several personalization techniques of FE-HBMs.Methods: Three 30° nearside oblique sled tests were reproduced using the SAFER HBM v8 and three personalization techniques were applied to this model to evaluate the influence on the risk of thoracic injuries. First, the overall mass of the model was adjusted to represent the weight of the subjects. Second, the model anthropometry and mass were modified to represent the characteristics of the post-mortem human subjects (PMHS). Finally, the spine alignment of the model was adapted to the PMHS posture at t = 0 ms, to conform to the angles between spinal landmarks measured in the PMHS. The following two metrics were used to predict three or more fractured ribs (AIS3+) of the SAFER HBM v8 and the effect of personalization techniques: the maximum posterior displacement of any studied chest point (Cmax), and the sum of the upper and lower deformation of selected rib points (PC score).Results: Despite having led to statistically significant differences in the probability of AIS3+ calculations, the mass-scaled and morphed version provided, in general, lower values for injury risk than the baseline model and the postured version being the latter, which exhibited the better approximation to the PMHS tests in terms of probability of injury. Additionally, this study found that the prediction of AIS3+ chest injuries based on PC Score resulted in higher probability values than the prediction based on Cmax for the loading conditions and personalization techniques analyzed within this study.Discussion: This study could demonstrate that the personalization techniques do not lead to linear trends when they are used in combination. Furthermore, the results included here suggest that these two criteria will result in significantly different predictions if the chest is loaded more asymmetrically.
The present study has three objectives: First, to analyze the chest deflection measured in nearside oblique tests performed with three post mortem human subjects (PMHS). Second, to assess the capab...
Regulation ECE-22.05/06 does not require a helmet penetration test. Penetration testing is controversial since it has been shown that it may cause the helmet to behave in a non-desirable stiff way in real-world crashes. This study aimed to assess the effect of the penetration test in the impact performance of helmets. Twenty full-face motorcycle helmets were penetration tested at multiple locations of the helmet shell. Then, 10 helmets were selected and split into two groups (hard shell and soft shell) depending on the results of the penetration tests. These 10 helmets were then drop tested at front, lateral, and top areas at two different impact speeds (5 m/s and 8.2 m/s) to assess their impact performance against head injuries. The statistical analyses did not show any significant difference between the two groups (hard/soft shell) at 5 m/s. Similar results were observed at 8.2 m/s, except for the top area of the helmet in which the peak linear acceleration was significantly higher for the soft shell group than for the hard shell group (230 ± 12 g vs. 211 ± 11 g; p-value = 0.038). The results of this study suggest that a stiffer shell does not necessarily cause helmets to behave in a stiffer way when striking rigid flat surfaces. These experiments also showed that hard shell helmets can provide better protection at higher impact speeds without damaging helmet performance at lower impact speeds.
Objective: The objective of this study is to analyze the 6 degrees of freedom (DOF) motion of the spine using the finite helical axis (FHA) in three postmortem human surrogates (PMHS) sled tests. Methods: The sled test configurations corresponded to a 30° nearside oblique impact at 35 km/h. Two different restraint system versions (RSv) were used. RSv1 was used for PMHS A and B while RSv2 was used for PMHS C. The 6 DOF motion of the head and three selected vertebrae have been analyzed using the FHA which describes the 3 D motion of a rigid body between two instants of time as a rotation about and a translation along a unit vector. A minimal amount of rotation is necessary to the FHA calculation, thus the FHA components have been calculated based on a pre-defined interval of 8° of rotation. Results: The analysis of the FHA components demonstrated right lateral bending until around 100 ms, when the rebound phase was reached and the head and the lower spine undergoes left lateral bending. The three PMHS exhibited, in general, flexion movement of the whole body and torsion to the right side of the occupant. This general motion can be associated to the effect of the seatbelt acting as a fulcrum of the rotational movement of the bony landmarks. The interaction of the PMHS with the retention system can be noted by analyzing the time in which the head and the upper spine initiated the rotation and the sudden changes of rotational direction of the three PMHS’s head. Conclusions: The rotational analyses have shown to be more sensitive to experimental events than the trajectory analyses for the studied physical tests. Additionally, the results presented in the present study contributes to the analysis of the body kinematics during an oblique impact and adds new experimental data for Human Body Models (HBM) and Anthropometric Test Devices (ATD) benchmarking.